Total Chlorine Analyzer – Model TC80
Total Chlorine Analyzer – Model TC80
Total Chlorine Analyzer – Model TC80 Total Chlorine Analyzer – Model TC80
ECD Total Chlorine Analyzer – Model TC80

The ECD TC80 Reagentless Total Chlorine Analyzer provides reliable, low-maintenance monitoring of total chlorine without the need for chemical reagents. Using a three-electrode amperometric sensor, it accurately measures both free and combined chlorine across low and high ranges up to 20 ppm. Its fully integrated, panel-mounted plug-and-play design enables fast installation and immediate operation, making it ideal for drinking water, industrial, and wastewater monitoring applications.

  • No Reagents Required: the TC80 Total Chlorine Analyzer sensor technology and automatic pH compensation is a reagentless design and keeps the cost of ownership low without having expensive reagents.
  • Compliant with EPA Method 334.0
  • Automatic Flow Control and Large Flow Tubes and Cells: greatly reduces clogs and blockages of the analyzer which is a common problem in other total chlorine analyzers and allows for easy cleaning.
  • Panel Mounted System Plumb and Play Design: the Total Chlorine Analyzer comes complete and is easy to install and ready to use.
  • TC80 Total Chlorine Analyzer Capability: Dual Masurements (2) 4 to 20 mA output, MODBUS and/or HART communication, (3) Alarm Relays, 24 VDC or 110/220 AC Power.
  • Auto Cleaning Option: The TC80 Total Chlorine Analyzer can be ordered with an auto cleaning option to keep the chlorine sensor clean from comtaminates for an extended period of time.

 

SENSORS AND FLOW TRAIN   
Chlorine Sensor: Digital protocol, Potentiostatic, Gold cathode/Silver-Silver Halide anode, 316L SS counter electrode
pH Sensor: Digital S80 protocol, 316L stainless steel body with replaceable electrode cartridge
Measurement Range: Chlorine: 0.05 to 20 ppm (High Range)
                0.005 to 2.00 ppm (Low Range)
pH: 4 to 14 pH
Operating Temperature: 0° C to 50° C (32° F to 122° F)
Min/Max Flow: 38 L/hr. to 300 L/hr. (10 gal/hr. to 80 gal/hr.)
Wetted Materials: PVC, PP, PVDF, PTFE, Glass, 316 SS
Process Connections: Input ¼” FNPT with barb fitting, Drain ¾” FNPT
Response Time: T90 in 2 minutes
Electrolyte Life: 3 to 6 months
   
TC80 ANALYZER   
Measurements:

Chlorine: 0.00 ppb to 22.00 ppm

pH: 0.00 to 14.00 pH

pH Compensation of Free Chlorine: pH 4 - 12
Display:

128 x 64 pixels (2.75” x 1.5”) LCD, Black on Grey background, Blue on White background with LED backlight on

Outputs:

(1) 4-20 mA for Total Chlorine set to Sensors Range

(1) 4-20 mA for pH (Optional) set 0-14 pH

Modbus RTU (standard)

Alarm Relay Ratings:

Three (3) SPDT, 1 form C, 250 VAC, 10 Amp resistive maximum, relays, user configurable as Hi/Lo alarms with expiration timer, Periodic Timers or Fault alarms

Input Power

Code -1 : 24 VDC (18-36 VDC @ 250 mW minimum)

Code -2 : 100-240 VAC, 50/60 Hz, 4W, protected with 250V, 1A, Slow Blow fuse

Enclosure:

Beige Polycarbonate, IP65, weatherproof, ½ DIN, (L x W x D) 5.7” X 5.7” X 3.5” (14.4cm X 14.4cm X 9.0cm)

Environmental Conditions: Outdoor use (IP65)
 

Ambient Temperature: -20°C - 70°C (24 VDC Models)

                                     -20°C - 60°C (100-240 VAC Models)

  Storage Temperature: -30°C - 85°C
 

Relative Humidity: 0 – 80%, up to 31°C
                              Decreasing linearly to 50% RH a 40°C

  Altitude: Up to 2000 m (6500 ft)
 

Mains Supply Voltage: Fluctuations up to ±10% of the nominal voltage
                                     Transient over voltages: CAT II
                                     Pollution Degree: 2