Reagentless Chlorine Dioxide Analyzer: The ECD CD80 Chlorine Dioxide Analyzer is a panel mounted, ready to use Chlorine Dioxide Analyzer. It is designed to monitor Chlorine Dioxide (ClO2) in drinking water, industrial cooling and rinse water, wastewater or other fresh water samples containing chlorine dioxide in the range of 0.05 to 20 ppm. The CD80 Chlorine Dioxide Analyzer features a plug and play design that incorporates a flow control device, a chlorine dioxide sensor and the T80 transmitter that are conveniently mounted on a PVC panel. Connect the sample and drain lines, connect the power and outputs and it is ready to use.
- No Reagents Required: the DC80 Chlorine Dioxide Analyzer sensor technology is a reagentless design and keeps the cost of ownership low without having expensive reagents.
- Automatic Flow Control and Large Flow Tubes and Cells: greatly reduces clogs and blockages of the analyzer which is a common problem in other total chlorine analyzers and allows for easy cleaning.
- Panel Mounted System Plumb and Play Design: the Chlorine Dioxide Analyzer comes complete and is easy to install and ready to use.
- CD80 Total Chlorine Analyzer Capability: (2) 4 to 20 mA outputs, MODBUS and/or HART communication, (3) Alarm Relays, 24 VDC or 110/220 AC Power.
- Auto Cleaning Option: The CD80 Chlorine Dioxide Analyzer can be ordered with an auto cleaning option to keep the chlorine sensor clean from contaminates for an extended period of time.
| SENSORS AND FLOW TRAIN | |
| Chlorine Sensor: | Polarographic, Gold cathode/Silver-Silver chloride anode, PTFE membrane |
| pH Sensor: | Digital S80 protocol, 316L stainless steel body with replaceable electrode cartridge |
| Measurement Range: |
Chlorine Dioxide: 0.05 to 20 ppm (High Range) 0.01 to 5.00 ppm (Low Range) pH: 0 to 14 pH |
| Operating Temperature: | 0° C to 50° C (32° F to 122° F) |
| Min/Max Flow: | 38 L/hr. to 300 L/hr. (10 gal/hr. to 80 gal/hr.) |
| Wetted Materials: | PVC, PP, PVDF, PTFE, Glass, 316 SS |
| Process Connections: | Input ¼” FNPT with barb fitting, Drain ¾” FNPT |
| Response Time: | T90 in 2 minutes |
| Electrolyte Life: | Up to 12 months |
| DC80 ANALYZER | |
| Measurements: |
Chlorine Dioxide: 0.05 ppm to 20.00 ppm (color inverted screen above 20.00 ppm to the limit of the sensor) pH: 0.00 to 14.00 pH |
| pH Compensation of Free Chlorine: | pH 5 - 10 (accuracy degrades rapidly above 9 pH) |
| Display: |
128 x 64 pixels (2.75” x 1.5”) LCD, Black on Grey background, Blue on White background with LED backlight on 100-250 VAC and 24 VDC powered instruments |
| Outputs: |
(1) 4-20 mA for Chlorine Dioxide set to Sensors Range (1) 4-20 mA for pH (Optional) set 0-14 pH Modbus RTU (standard) |
| Alarm Relay Ratings: |
Three (3) SPDT, 1 form C, 250 VAC, 10 Amp resistive maximum, relays, user configurable as Hi/Lo alarms with expiration timer, Periodic Timers or Fault alarms |
| Input Power |
Code -1 : 24 VDC (18-36 VDC @ 250 mW minimum) Code -2 : 100-240 VAC, 50/60 Hz, 4W, protected with 250V, 1A, Slow Blow fuse |
| Enclosure: |
Beige Polycarbonate, IP65, weatherproof, ½ DIN, (L x W x D) 5.7” X 5.7” X 3.5” (14.4cm X 14.4cm X 9.0cm) |
| Environmental Conditions: | Outdoor use (IP65) |
|
Ambient Temperature: -20°C - 70°C (24 VDC Models) -20°C - 60°C (100-240 VAC Models) |
|
| Storage Temperature: -30°C - 85°C | |
|
Relative Humidity: 0 – 80%, up to 31°C |
|
| Altitude: Up to 2000 m (6500 ft) | |
|
Mains Supply Voltage: Fluctuations up to ±10% of the nominal voltage |