R3-100
R3-100

3-Axis Ultrasonic Anemometer

Gill 3-axis Research range of ultrasonic anemometers offers users a number of different instruments. This range is valued for the quality of its measurements and is used by recognised experts to gather data they reply upon for their research and publications. 

The Research range includes models featuring horizontal head configurations for highly accurate vertical flow analysis, with minimal interruption from anemometer geometry. These models have a built in inclinometer to assist set-up on towers or masts.

The R3-100™ anemometer is Gill’s class-leading 3-axis anemometer ideal for scientific research applications, with a fast sampling rate of 100Hz. This 3-axis ultrasonic anemometer is used extensively for the determination of fluxes using the Eddy Covariance method.

R3-100 will monitor wind speeds of 0-45m/s, with analogue, sonic temperature, speed of sound and U, V, W vector outputs provided as standard and optional analogue and PRT inputs available. The R3-100 is of aluminium/carbon fibre construction and will operate effectively in environmental temperatures from -40°C to +60°C. Optional accessories are available such as cables, sensor input units (analogue inputs) and power supplies.

  • 3-axis research anemometer
  • 100Hz output rate
  • 0-45 m/s wind speed
  • 0-360º wind direction
  • U, V, W vector outputs
  • Sonic temperature output
  • Aluminium/carbon fibre construction
  • Custom calibration provided as standard

 

 

WIND SPEED  
Range 0 - 45 m/s
Resolution 0.01 m/s
Accuracy <1% RMS
   
DIRECTION  
Range 0 - 360°
Resolution
Accuracy* <±1° RMS
   
SPEED OF SOUND  
Range 300-370 m/s
Resolution 0.01 m/s
Accuracy < ±0.5% @ 20ºC
   
MEASUREMENT  
Ultrasonic sampling rate 100 Hz
Parameters UVW, Speed of Sound
   
DIGITAL OUTPUT  
Communication RS422 full duplex, 8 data bits, 1 stop bit, no parity
Baud rates 2400 - 115200
Output rate Selectable 0.4 to 100Hz
   
ANALOGUE INPUTS (VIA OPTIONAL SIU)  
Quantity 6 differential inputs
Sampling rate 100Hz
Range and resolution ±5V, 14 bits
Accuracy <0.1% of FSR
   
ANALOGUE OUTPUTS (VIA SUPPLIED PCIA)  
Quantity 7 (U, V, W, SoS, PRT plus 2 analogue inputs)
Sampling ±10, ±20, ±30, ±60 m/s
Update rate 0.4 to 100Hz
Range and resolution ±2.5V, 14 bits
Accuracy <0.25% of FSR
   
PRT INPUT**  
Input resolution 0.01°C
Input accuracy <0.01°C (0 to 50°C) < 0.15°C (-40°C to +60°C)
   
INCLINOMETER (OPTIONAL)  
Range and resolution ±20°C, 0.01°
Null repeatability ± 0.15°
Accuracy ±0.3° (from -10° to 10° of inclination)
   
POWER REQUIREMENT  
Anemometer 9-30V dc <4w (eg. <150mA @ 24V DC or 300mA @ 12V dc)
   
ENVIRONMENTAL  
Protection Class IP65
Operating Temp -40°C to +60°C
Precipitation Operation to 300 mm per hour
EMC BS EN 50081-1: 1992 (Emissions) BS EN 50082-1: 1992 (Immunity)

 

Search

Enter the terms you wish to search for.