NR-LITE2-L Net Radiometer
NR-LITE2-L Net Radiometer

The NR-LITE2 includes two black conical absorbers—one facing upward and the other facing downward. The absorbers are coated in PTFE, making them resistant to weather without using a fragile plastic dome. Both absorbers are calibrated to an identical sensitivity coefficient.

The NR-LITE2 has a bubble level to ensure proper installation and a rod that deters birds from roosting on the sensor. It produces a millivolt signal that is measured directly by a Campbell Scientific data logger.

Benefits and Features

  • Compatible with most Campbell Scientific data loggers
  • Integrated bubble level ensures proper installation
  • Includes rod that deters birds from roosting on the radiometer
  • PTFE-coated absorbers are weather-resistant without using a fragile plastic dome

The NR-LITE2, manufactured by Kipp & Zonen and cabled for use with Campbell Scientific data loggers, is a rugged net radiometer that measures the energy balance between incoming short-wave and long-wave infrared radiation relative to surface-reflected short-wave and outgoing long-wave infrared radiation. It is directly connected to a Campbell Scientific data logger and is widely used in agriculture and hydrology applications.

  • NR-LITE2-L Net Radiometer measures the energy balance between incoming short-wave and long-wave infrared radiation relative to surface reflected short-wave and outgoing long-wave infrared radiation.
  • Includes two black conical absorbers—one facing upward and the other facing downward.
  • The absorbers are coated in PTFE, making them resistant to weather without using a fragile plastic dome.
  • Calibrated to an identical sensitivity coefficient.
  • Includes a bubble level to ensure proper installation and a rod that deters birds from roosting on the sensor.
  • Produces a millivolt signal that is measured directly by a Campbell Scientific data logger.
  • The only difference between the NR-Lite and the NR-Lite2 is the color of the wires.
Sensor Two black conical absorbers—one facing upward and the other facing downward
Measurement Description Measures incoming and outgoing short-wave and long-wave radiation
Spectral Range 0.2 to 100 µm
Response Time < 20 s (nominal)
Sensitivity 10 µV W-1 m2 (nominal)
Output Range ±25 mV
Measurement Range ±2000 W m-2
Operating Temperature Range -40° to +80°C
Sensor Diameter 8.0 cm (3.1 in.)
Support Arm Diameter 1.6 cm (0.6 in.)
Support Arm Length 80 cm (31.5 in.)
Sensor Weight 200 g (7.0 oz)
Support Arm Weight 635 g (23 oz)