MeteoTemp RH+T with pressure
MeteoTemp RH+T with pressure

3-in-1 sensor probe with the same form factor as above 2-in-1 probe. Adds Pressure to the already superb Temperature, Humidity, Dew Point and Frost Point probe without increasing power consumption to maintain the same WMO accuracy requirements for Temperature and Humidity. Features a highly reliable sealed barometric pressure transducer in the sensor head. Also features triple lightning protection and Surge, Transient & ESD protection.

MeteoTemp RH+T has proven to have one of the lowest measurement uncertainties in the market for combined temperature and humidity measurement. A high-quality sealed barometric pressure sensor adds unbeatable value to the already exceptional MeteoTemp RH+T. Combined output features temperature, humidity, dew point, frost point & barometric pressure data.

Ultra-low power performance is not affected by the addition of pressure sensor. Total combined power consumption remains around 800 µA, with the addition of only 20 µA by the pressure sensor to maintain the 5x advantage over most meteorological temperature and humidity probes. 

  • 3 sensors in 1 simplify your systems and extend battery life

  • Remove self-heating from your measurement data

  • Excellent value with easy re-calibration and traceability features

  • Lightning protection for ultimate reliability of air-temperature measurement

 

Temperature (silicone type)  
Dew point / Frost point ±0.2°C (typical)
Stability <0.02°C per year
Resolution 0.1°C
Measuring range -40°C…105°C
Operating range -40°C…105°C
Response* 5-30s
Meets WMO yes
   
Relative Humidity (capacitive type)  

Acuracy

 

±1.8%RH @25°C hysteresis ±1%
Stability <0.25%RH per year
Resolution 0.1%RH
Measuring range 0…100%RH
Operating range 0…100%RH
Response* 8-30s
Meets WMO yes
   
Dew point / Frost point  
Accuracy (calculated)
Resolution 0.1°C
Measuring range -40°C…105°C
Operating range -40°C…105°C
Response* 8-30s
Meets WMO yes
   
Barometric Pressure (piezo-resistive type)  
Accuracy ±1.5hPa @25°C (750…1100hPa)

Stability

-1 hPa per year
Resolution 0.012hPa
Measuring range 300…1100hPa
Operating range 300…1100hPa
Response* 0.1s
Meets WMO no
   
Output signal & communication RS-485 with Modbus RTU or ASCII
Supply Voltage 5...15 VDC with reverse polarity protection (startup in-rush <100mA for 1ms)
Power consumption 800 µA at 1Hz output including RS485 communication
Lightning & surge protection per IEC EN 61000-4-2, EN 61000-4-4, EN 61000-4-5 on both data & power lines, Surge, EFT/ Burst, ESD 15 kV
Operating temperature & humidity -40°C to +105°C, 0% to 100%RH
Connection Bayonet connector with silicone o-ring
IP – Protection rating IP66W (DIN 40050)
Dimensions Length = 133 mm (164 mm with mating connector), Ø17 mm base, Ø12 mm PTFE sensor cap
Weight (mass) aprox. 20 g (without mating connector and cable)

 

Search