HD33MT Weather Station Data Logger
Weather station data logger for remote environmental monitoring.
- 4 analog inputs, 2 counting contact inputs, RS485 Modbus and SDI-12 Master port
- 4G/3G/GSM(2G)/GPRS transmission by e-mail, FTP or HTTP server, with SMS and e-mail alarms
- IP65 polycarbonate housing, solar-panel or DC power, optional 12 V / 3.4 Ah backup battery
Overview
The Senseca HD33MT is a weather station data logger for remote monitoring of environmental measurements such as temperature, humidity, wind speed, rainfall and solar irradiance, suited to meteorology, agriculture, smart cities and industrial monitoring. Its flexible input structure has 4 independently configurable analog inputs, 2 voltage-free counting contact inputs, an RS485 port with Modbus-RTU (or Modbus TCP/IP on Ethernet versions) and an SDI-12 Master port. A 4G module, backward compatible with 3G, GSM(2G) and GPRS, sends data by e-mail, FTP or to an HTTP server, while control by SMS or TCP/IP connection reduces travel to remote sites. The IP65 polycarbonate housing mounts on masts up to 60 mm and operates from -40 to +70 °C on versions without LCD, and solar-panel power, external DC supply and an optional 12 V / 3.4 Ah backup battery keep it logging in off-grid locations.
Typical applications
- Remote weather stations
- Meteorology
- Agriculture
- Smart cities
- Industrial monitoring
- Off-grid environmental monitoring sites
Key Features
- 4 independently configurable analog inputs: 0…50 mV, -50…+50 mV, 0…1 V, 0…10 V, 0/4…20 mA, Pt100, Pt1000, thermocouple, potentiometer, pyrgeometer
- 2 voltage-free counting contact inputs for rain gauges and anemometers
- RS485 port with Modbus-RTU or Modbus TCP/IP, configurable as Master or Slave, plus SDI-12 Master port
- Measuring and logging intervals from 1 s to 1 hour, with circular or stop-when-full memory
- Rainfall functions: maximum rainfall rate, daily, total and per-interval rainfall
- High and low alarm thresholds with hysteresis and delay, SMS/e-mail alerts and 2 voltage-free NO alarm outputs
- Switched power outputs to power external sensors only during acquisition
- HD35AP-S PC software for configuration, real-time display and data download
- Options: Ethernet module, internal barometric sensor and custom LCD
Benefits
- Remote data access: 4G/3G/GSM/GPRS sends measurements by e-mail, FTP or HTTP server without site visits
- Sensor flexibility: 4 analog inputs, 2 counting inputs, RS485 Modbus and SDI-12 connect weather station sensors
- Off-grid operation: solar-panel power and an optional 12 V / 3.4 Ah battery support remote installations
- Outdoor-ready housing: IP65 polycarbonate housing operates at -40…+70 °C without LCD
- Actionable alarms: high and low thresholds trigger SMS/e-mail alerts and 2 voltage-free NO outputs
- Low power consumption: operates for weeks without recharging the internal battery
Specifications
GENERAL SPECIFICATIONS |
|
Power supply | With rechargeable battery: 18…30 Vdc |
Power consumption @ 12 Vdc | Without mobile network activity: < 4 mA without Ethernet module; ~200 mA with Ethernet module |
Battery | Optional internal lead 12 V / 3.4 Ah |
Measuring and logging interval | From 1 s to 1 hour (1, 2, 5, 10, 15, 30 s / 1, 2, 5, 10, 15, 30, 60 min) |
Internal memory | Circular management or stop logging if memory is full |
Alarm | E-mail and SMS |
Display | Optional custom LCD |
Cellular connectivity | 4G/3G/GSM(2G)/GPRS, external antenna |
Internal clock drift | ±2 ppm (0…+40 °C) / ±5 ppm (-40…+70 °C) |
INPUTS AND PORTS |
|
Analog inputs | 4 independently configurable inputs (0…50 mV, -50…+50 mV, 0…1 V, 0…10 V, 0…20 mA or 4…20 mA, Pt100, Pt1000, thermocouple, potentiometer, pyrgeometer) |
Counting inputs | 2 voltage-free counting contact inputs (switching frequency 50 Hz max., hold time 10 ms min.) |
Digital ports | 1 RS485 port with Modbus TCP/IP or Modbus-RTU protocol, configurable as "Master" or "Slave" |
Communication ports | Mini-USB connector (for connection to PC) |
External probes connection | M12 connectors or cable glands |
INPUT SPECIFICATIONS |
|
Pt100 / Pt1000 | Range -200…+650 °C, resolution 0.1 °C, accuracy ±0.1 °C (excluding probe error), 2, 3 or 4 wires |
Thermocouple | Types K, J, T, N, E (non-isolated inputs, use thermocouples with isolated hot junction) |
0/4…20 mA | Internal shunt 50 Ω, resolution 16 bit, accuracy ±2 µA |
0…50 mV / -50…50 mV / 0…1 V / 0…10 V | Input resistance 100 MΩ, resolution 16 bit, accuracy ±0.01% f.s. |
Potentiometer | 10 kΩ typical, resolution 16 bit, accuracy ±0.01% f.s. |
Atmospheric pressure (optional internal sensor) | Piezoresistive, 300…1100 hPa, resolution 0.1 hPa |
Rainfall measurement | Maximum rainfall rate, daily rainfall, total rainfall, rainfall in the logging interval |
ENVIRONMENTAL & MECHANICAL |
|
Operating conditions | Version without LCD: -40…+70 °C / 0…100 %RH |
Weight | 2.8 kg approx. |
Housing | Dimensions: 270 x 170 x 110 mm (excluding external antenna) |
Installation | Fixing to a max 60 mm diameter mast |
ORDERING CODES | HD33 [LCD] MT [Barometric sensor] . [Connectivity] |
LCD | Blank = without LCD |
Internal barometric sensor | Blank = without internal barometric sensor |
Connectivity | 4 = 4G/3G/GSM(2G)/GPRS |
Note | Supplied with the HD35AP-S software, downloadable from the website. Battery, probes, sensors and USB cable CP23 must be ordered separately. SIM card and Ethernet cable (for models with Ethernet communication) are not included. |
Downloads
| HD33MT Family Datasheet (EN) | DownloadHD33MT Family Datasheet (EN) |
|---|---|
| HD33MT Family User Manual (EN) | DownloadHD33MT Family User Manual (EN) |