WETEC
403 CMT Multilevel Systems thumbnail 1
403 CMT Multilevel Systems thumbnail 2
403 CMT Multilevel Systems thumbnail 3

Solinst

403 CMT Multilevel Systems


Single-tube multilevel groundwater monitoring with up to 7 depth-discrete zones.

  • Continuous multichannel tubing (CMT) with no joints
  • 7-Channel System: 1.7" (43 mm) tubing, up to 7 monitoring zones
  • 3-Channel System: 1.1" (28 mm) tubing, up to 3 monitoring zones
  • Sand & bentonite backfill or natural formation collapse; 3-Channel also uses bentonite & sand cartridges
  • Over 10,000 installations worldwide
Quantity
1

Overview

Since 1999, the CMT Multilevel System has proven to be reliable, easy to install and inexpensive. It provides site assessors with a better understanding of three-dimensional groundwater flow and the distribution of contaminants in the subsurface, so remediation strategies can be targeted more precisely. Two systems are available: the 7-Channel System uses 1.7" (43 mm) OD polyethylene tubing, segmented into seven channels, for monitoring up to 7 depth-discrete zones. The 3-Channel System uses the same material and construction, but is only 1.1" (28 mm) in diameter, developed for smaller diameter installations, especially direct push where the annulus for seal placement is narrow.

Typical applications

  • Proven and effective for PFAS monitoring
  • Identify vertical as well as horizontal contaminant distribution with transect monitoring
  • Ideal for shallow wells in high water table environments
  • Multilevel water sampling and level monitoring in unconsolidated soils or bedrock
  • Dewatering impact assessments at construction & mining sites
  • Mass transport calculations and mass flux estimation
  • Monitoring of natural attenuation or remediation processes, and documentation of its effectiveness
  • VOC, MTBE and Perchlorate monitoring at NAPL sites
  • Determination of the best location for reactive barrier walls, the Waterloo Emitter™ and other remediation methodologies
  • Vapor monitoring with special wellhead seals
  • Helps optimize design and performance assessment of remedial options

Key Features

  • Low cost and easy to install and use
  • Single tube design with no joints allows reliable seals between zones
  • Up to 7 depth-discrete zones in a single tube
  • Locate ports and seals exactly where desired
  • Installs quickly in large direct push casing and boreholes
  • One 7-Channel CMT System can be completed by two people in under 3 hours, 3-Channel even faster
  • Avoid the risk of short-circuiting when using well nests
  • Borehole not left open to allow cross contamination
  • Isolate zones using traditional sand and bentonite layers or 3-Channel Cartridges
  • Minimizes the risk of producing new contaminant pathways vs using well clusters with overlapping adjacent sand packs
  • Over 10,000 installations worldwide

Benefits

  • Accurate site assessment: Provide the most accurate 3-D assessment of a site and are vital to understanding vertical contaminant distribution
  • No contaminant mixing: Eliminates contaminant mixing in long screened wells, which averages out heads and contaminants and masks narrow zones of contamination. Multilevels monitor discrete intervals
  • No ambient flow bias: Properly sealed multilevels avoid ambient flow within a well, preventing cross communication of contaminants between zones
  • Mass flux data: A transect of multilevels across the groundwater flow path provides data for mass flux calculations
  • Optimized remediation design: Data from multilevels accurately defines the thickness, concentration variations and extent of a plume
  • Documents change: Allow documentation of changes in the concentration and delineation of any contaminant plumes, including PFAS
  • Saves cost: Reduced permitting and drilling costs. Narrow tubes allow smaller purge volumes, reduced disposal costs, efficient low flow sampling and rapid response to pressure changes, all of which reduce field time
  • Low cost, low disturbance: Low cost compared to multiple individual wells, and minimizes site disturbance

Specifications

MODEL 403 CMT MULTILEVEL SYSTEM - 7-CHANNEL

 

Tubing diameter

1.7" (43 mm)

Monitoring zones

up to 7

Channel diameter

6-Pie: 0.4" (10 mm)
1-Hex: 3/8" (9.5 mm)

Channel volume

40 mL/ft.
30 mL/ft. (center)

Installation options

Sand & bentonite backfill
Natural formation collapse

Coil lengths (Coil 4 ft. dia.)

100 ft. (30 m), 200 ft. (60 m) & 300 ft. (90 m)

Centralizer sizes (other sizes optional)

4.4" standard (112 mm)

Borehole diameter recommended for backfill installations

4" (100 mm) and larger

 

 

MODEL 403 CMT MULTILEVEL SYSTEM - 3-CHANNEL

 

Tubing diameter

1.1" (28 mm)

Monitoring zones

up to 3

Channel diameter

3-Hex: 3/8" (9.5 mm)

Channel volume

30 mL/ft.

Installation options

Bentonite & sand cartridges
Sand & bentonite backfill
Natural formation collapse

Coil lengths (Coil 4 ft. dia.)

100 ft. (30 m), 200 ft. (60 m) & 500 ft. (150 m)

Centralizer sizes (other sizes optional)

3.3" standard (84 mm)

Borehole diameter recommended for backfill installations

3.5" (89 mm) and larger

Borehole diameter for installations with seal and sand cartridges

2.8" - 3.5" (71 mm - 89 mm)

 

 

3-CHANNEL SAND AND BENTONITE CARTRIDGES

 

Diameter

Approximately 2.4" (61 mm)

Maximum borehole diameter for proper expansion and sealing

Nominal 3.5" (90 mm)

 

 

MONITORING OPTIONS

 

Water levels

Model 102 Water Level Meter and 102M Mini Water Level Meter with 4 mm (0.157") diameter P4 Probe can be used in any CMT channel

Peristaltic Pump

Suction lift limit of approximately 7.5 m (25 ft)

Mini Inertial Pump

Polyethylene tubing: depths to 15 m (50 ft)
PTFE tubing: depths to 45 m (150 ft)

Micro Double Valve Pump

3/8" (9.5 mm) diameter flexible PFAS-free PTFE or polyethylene tubing
Optional multi-purge manifold for depths up to 73 m (240 ft)

Vapor samples

Vapor Wellhead Assembly for depth discrete vapor samples

Downloads

403 CMT Multilevel System Datasheet (EN) Download403 CMT Multilevel System Datasheet (EN)
403 CMT Multilevel Operating Instructions Download403 CMT Multilevel Operating Instructions
403N CMT Multilevel Operating Instructions Download403N CMT Multilevel Operating Instructions