WETEC

Solinst

404 Inertial Pump


A simple, reliable inertial pump for groundwater sampling: a riser tube fitted with a one-way footvalve.

  • Easily operated by hand, or with a surface pumping mechanism
  • Operates to 200+ ft (60+ m)
  • For 0.4" to 6" ID wells (12 mm to 150 mm)
  • Essentially maintenance free
Quantity
1

Overview

The Solinst Model 404 Inertial Pump is a simple, reliable pump that provides a sampling option for groundwater monitoring. The pump consists of a riser tube fitted with a one-way footvalve, with the key part being the check ball located in the foot of the pump. It is a simple alternative to using a bailer. To obtain a sample, a footvalve is hand-threaded onto the tubing and lowered to the desired depth in a well or borehole. The assembled tubing and footvalve are then repeatedly lowered and raised approximately 6" to 12" (15 to 30 cm). A slug of water enters the tubing on the downward stroke and is retained, as the valve closes, on the upward stroke, so the water gradually rises in the tubing and discharges at surface. It can be operated by hand at shallow depths, or by using a surface pumping mechanism.

Typical applications

  • Groundwater sampling and purging in 0.4" to 6" ID wells
  • Well development
  • Dedicated sampling to avoid cross-well contamination
  • Sampling inside CMT Multilevel Systems, with the 1/4" (6 mm) Mini Inertial Pump

Key Features

  • Riser tube with a one-way footvalve (check ball in the foot of the pump)
  • Easily operated by hand; surface pumping mechanisms powered manually, or by gasoline or electricity, are available for higher volumes
  • Operates to 200+ ft (60+ m)
  • For 0.4" to 6" ID wells (12 mm to 150 mm)
  • Flow rates up to 7.6 L/min (2 gpm) with 5/8" x 1/2" (16 mm x 12.5 mm) tubing
  • Footvalves in Delrin or stainless steel, in sizes from 5/8" to 1" (16 mm to 25 mm), with tapered threads that self-tap onto either end of the riser tubing
  • Riser tubing in HDPE (most frequently used) or PTFE, in coils of 100, 200 or 500 ft (30, 60 or 150 m)
  • 1/4" (6 mm) Mini Inertial Pump for sampling inside CMT Multilevel Systems
  • Efficient purging rates and high quality samples
  • Essentially maintenance free
  • Works with Model 860 Disposable In-line Filters

Benefits

  • Easy operation: Easily operated by hand, with fast, easy operation.
  • Good for well development: A minimum annular space between the footvalve and the well casing can create a strong churning effect that helps remove silt and fine sand, and turbidity is greatly reduced after well development.
  • Silty water: Pumping silty water is possible. If silt settles and clogs the footvalve, it can be cleared by unscrewing the footvalve from the tubing and tapping the footvalve and tubing to dislodge the sediment.
  • Ideal for dedication: Low cost, avoids cross-well contamination, eliminates repeated pump decontamination, avoids costly field and wash blanks, and reduces time in the field.
  • Simple alternative to a bailer: The pump works in the same way as a bailer, with a check ball in the foot.

Specifications

SPECIFICATIONS

 

Pump type

Inertial pump: riser tube with a one-way footvalve

Operating depth

200+ ft (60+ m)
Easily operated by hand at shallow depths, or with a surface pumping mechanism

Well diameter

0.4" to 6" ID (12 mm to 150 mm)

Stroke

Repeatedly lower and raise the tubing and footvalve approximately 6" to 12" (15 to 30 cm)

Flow rate

Up to 7.6 L/min (2 gpm) with 5/8" x 1/2" (16 mm x 12.5 mm) tubing
Varies with tubing length, submergence depth of the footvalve, flexing of the tube, and the rate at which the tubing is pumped
Higher volumes with electric or gasoline powered surface pumping mechanisms

Riser tubing

High density polyethylene (HDPE) most frequently used, PTFE also available
Coils of 100, 200 or 500 ft (30, 60 or 150 m)

Footvalve

Check ball inside the valve body
Delrin or stainless steel, 5/8" to 1" (16 mm to 25 mm) diameters
Tapered threads self-tap onto either end of the riser tubing; thread on by hand at least 1/2" (12 mm)

VOC samples

Insert approximately 8 ft (2.5 m) of 1/4" (6 mm) sample tubing into the riser tube, leaving about 1 ft (30 cm) protruding. After pumping stops, the sample tube acts as a gravity flow siphon.
For VOC samples free of any contact with air, Solinst recommends the Model 407 Bladder Pump

In-line filters

Model 860 Disposable In-line Filters: 0.45 µm membrane, 650 cm2 filtration area
3/8" (9.5 mm) hose barb inlet and outlet, 1/8" NPTM vent/drain connection

 

 

PUMP ASSEMBLIES

 

403 MIP (Mini Inertial Pump)

Footvalve 1/4" (6 mm)
Tubing 1/4" x 0.17" (6 mm x 4.3 mm)
Two stainless steel inserts and a check ball, installed inside the tubing

D16

Footvalve 5/8" (16 mm)
Tubing 5/8" x 1/2" (16 mm x 12.5 mm)

SS16

Footvalve 5/8" (16 mm)
Tubing 5/8" x 1/2" (16 mm x 12.5 mm)

SS19

Footvalve 3/4" (19 mm)
Tubing 5/8" x 1/2" (16 mm x 12.5 mm)

D25

Footvalve 1" (25 mm)
Tubing 5/8" x 1/2" (16 mm x 12.5 mm)

Drawing

Inertial-Pump-Operation

Downloads

404 Inertial Pump Datasheet (EN) Download404 Inertial Pump Datasheet (EN)
404 Inertial Pump Operating Instructions (EN) Download404 Inertial Pump Operating Instructions (EN)