WETEC
407 Bladder Pumps thumbnail 1
407 Bladder Pumps thumbnail 2

407 Bladder Pumps


Pneumatic drive groundwater sampling pumps with easy-to-replace Santoprene bladder cartridges.

  • No air/water contact during sampling, for VOC groundwater monitoring
  • 316 stainless steel (1.66" and 1") or PVC (1.66")
  • Stainless steel to 150 m (500 ft), PVC to 30 m (100 ft)
  • Regular flow or low flow purging and sampling, portable or dedicated
Quantity
1

Overview

Solinst 407 Bladder Pumps are pneumatic drive groundwater sampling pumps that provide consistent, high-quality samples in all types of applications. The bladder guarantees that the drive air or gas does not contact the sample, so there is no air/water contact during sampling and no degassing or contamination, which suits them to VOC groundwater monitoring. Durable Santoprene bladder cartridges can be replaced in the field in just a few minutes, with no special tools. The pumps are available in 316 stainless steel (1.66" and 1") or PVC (1.66"), for portable or dedicated use, and are suited to both regular flow and low flow purging and sampling.

Typical applications

  • VOC groundwater sampling
  • Low flow purging and sampling
  • Municipal, industrial and general environmental groundwater sampling (stainless steel)
  • Metals sampling and highly corrosive liquids (PVC)
  • Sampling under landfills, tailings, storage tanks or contaminant plumes
  • Sediment-laden water or dry pumping conditions
  • Leachate and product pumping, including strong solvents and corrosive chemicals
  • Dedicated pumps for long-term groundwater monitoring

Key Features

  • Santoprene bladders, used for their chemical resistance and inert properties, suitable for harsh environments and potable water applications
  • Easy-to-replace bladder cartridges: the bladder and intake filters are replaced in the field in a few minutes, with no special tools
  • No air/water contact: drive air or gas never touches the sample, avoiding degassing or contamination
  • Meets the most rigorous US EPA standards for VOC groundwater monitoring
  • 316 stainless steel 1.66" (42 mm) and 1" (25 mm), or PVC 1.66" (42 mm)
  • Stainless steel pumps lift from depths up to 150 m (500 ft) below grade; PVC pump operates up to 30 m (100 ft) below grade
  • Low flow output of 100 ml/min or less with the Solinst 464 Electronic Pump Control Unit
  • Flow rates up to 1.5 L/min for larger purge volumes
  • Operates effectively at almost any angle
  • Survives dry pumping, dirty air and sand: bladders are not damaged by sediment-laden water or dry pumping
  • Easy to decontaminate: quick to disassemble, with no tools required
  • Portable systems on a free-standing reel, or dedicated systems with well caps
  • Optional Freeze Protection Kit to prevent freezing in the groundwater sampling line

Benefits

  • High quality samples: Consistently accurate groundwater samples with excellent VOC sample integrity.
  • Gentle pumping: The slow compression of the bladder and low flow rates minimize turbulence, so volatiles are not stripped from the sample.
  • Easy bladder replacement: Durable Santoprene bladders are ideal for dedication, and the new bladder cartridges make them extremely easy to replace.
  • Chemical resistance: Santoprene is resistant to various chemicals, including acids, bases and petroleum products, and is flexible and resilient for repeated use.
  • Cost and time savings: Reduced need for repeat sampling and shorter time for each sampling round. Low purge volumes ensure rapid sampling and lower purged water disposal costs.
  • Simplicity: The controller, air compressor and flow-through cell can be easily transported by one person to any site. Hookup to the pump is by barb fittings.
  • Dedicated pumps: Dedication avoids cross-contamination and saves time, as there is no decontamination between sampling events.

Specifications

PUMP VERSIONS

 

1.66" (42 mm) stainless steel

316 stainless steel body
PTFE or 316 stainless steel check balls
50 mesh intake filter
Maximum depth 150 m (500 ft) below grade
Maximum operating pressure 250 psi

1" (25 mm) stainless steel

316 stainless steel body, for narrower applications and use in the Waterloo Multilevel System
PTFE or 316 stainless steel check balls
Maximum depth 150 m (500 ft) below grade
Maximum operating pressure 250 psi

1.66" (42 mm) PVC

PVC body, suited to metals analysis and highly corrosive liquids
PTFE check balls
Porous polyethylene screen
Maximum depth 30 m (100 ft) below grade
Maximum operating pressure 50 psi

 

 

SPECIFICATIONS

 

Pump type

Pneumatic drive bladder pump

Body diameter

1.66" (42 mm) standard
1" (25 mm), stainless steel only

Body length (1.66")

2 ft and 4 ft (0.6 m and 1.2 m)

Bladder

Santoprene, with Delrin and acetal copolymer cartridge

Drive gas

Compressed air or nitrogen

Drive pressure

Intake depth below ground surface in feet, divided by 2.3, plus 20 psi for line loss
Example: pump intake 100 ft below ground surface gives a minimum of 63 psi

Flow rate

Up to 1.5 L/min, varying with pump depth, depth below water level, drive and sample tubing size, drive and vent cycle times, gas pressure and aquifer recharge
Example: 1.66" x 2 ft (42 mm x 610 mm) pump at 100 psi, with 1/4" OD drive line and 3/8" OD sample line, 50 ft (15 m) below grade with 25 ft (7.5 m) below water level gives 1.5 L/min
100 ml/min or less with the 464 Electronic Pump Control Unit

Tubing connection

1/4" (6 mm) tubing barbs on the drive and sample stems
Optional 3/8" barbs for the 1.66" stainless steel pump

Tubing

1/4" (6 mm) single line or 1/4" (6 mm) OD dual skip-bonded LDPE
PTFE-lined LDPE and other tubing sizes available

Portable system

Supplied on a free-standing reel with 1/4" (6 mm) OD dual skip-bonded tubing
Use a Solinst Model 103 Tag Line to lower and support the pump in the well

Dedicated system

Well caps slip onto 2" (50 mm) wells, with adaptors for 4" (100 mm) wells
Quick-connect fittings for drive and sample tubing, for 1/4" OD (6 mm) and 3/8" OD (9 mm) tubing
3 ft (0.9 m) discharge line with each cap
Access hole for a Solinst Model 101 Water Level Meter or Levelogger
Eyebolt for a pump support cable

Compressor filter

An external filter is recommended if using a compressor to operate the pump

 

 

USED WITH

 

Model 464 Electronic Pump Control Unit

125 psi and 250 psi versions
4 AA alkaline batteries, up to 100 hours of normal use
Preset sample modes, up to 99 user-created flow rates saved in memory
Can be operated manually from a compressed gas source

12 Volt Oil-Less Air Compressor

12 V DC power source with alligator clips
Operates up to 150 psi
2 US gallon (7.6 L) air tank rated to 175 psi
21 lbs (9.5 kg)
Suited to low flow applications at depths of less than 30 m (100 ft)

Model 800 Low-Pressure Packers

Single point or straddle packers to reduce purge volumes
Sizes to fit 2" (50 mm) to 5" (127 mm) diameter wells

Model 860 Disposable In-line Filters

For use on the sample discharge tube, adaptable to many tubing sizes

Drawing

Bladder-Pump-Operating-Principles-small

Downloads

407 Bladder Pump Datasheet (EN) Download407 Bladder Pump Datasheet (EN)
1.66" Stainless Steel Bladder Pump Operating Instructions (EN) Download1.66" Stainless Steel Bladder Pump Operating Instructions (EN)
1" Stainless Steel Bladder Pump Operating Instructions (EN) Download1" Stainless Steel Bladder Pump Operating Instructions (EN)
1.66" PVC Bladder Pump Operating Instructions (EN) Download1.66" PVC Bladder Pump Operating Instructions (EN)
1.66" Stainless Steel (No PTFE) Bladder Pump Operating Instructions (EN) Download1.66" Stainless Steel (No PTFE) Bladder Pump Operating Instructions (EN)