Solinst
429 Point Source Bailer
Stainless steel bailer with dual ball valves for collecting groundwater samples from a specific depth.
- Top and bottom ball valves keep the sample from mixing with water from other depths
- 316 stainless steel body with PTFE ball valves and o-rings
- Diameters of 0.5", 1", 1.5" and 2" in lengths of 2 ft, 3 ft and 4 ft
- The 0.5" model suits narrow tubes and direct push devices
- Stainless steel sample release device included
Overview
The Solinst Model 429 Point Source Bailer is stainless steel and has dual ball valves, top and bottom. This prevents a sample collected at a discrete depth from mixing with water from other depths during retrieval. It is a simple and cost effective device for aquifer profiling and for collecting samples from distinct levels, and purging and disposal of purge water can be avoided. The miniature 0.5" (12.7 mm) diameter model is ideal for use in narrow tubes and direct-push devices.
Typical applications
- Point source sampling of groundwater from specific depths, collecting water that has just flowed into the well at the sampling point
- Profiling an open borehole or screened well
- Collecting samples from distinct levels or points of inflow
- Aquifer profiling
- Point source sampling in hard to access locations
- Sampling in narrow tubes and direct push devices (0.5" model)
Key Features
- Dual ball valves, top and bottom, keep the sample from mixing with water at other levels
- Both ball valves open as the bailer is lowered, so water flows through it; they close when it is raised slowly and steadily
- Top ball valve prevents mixing with water at higher levels; bottom valve prevents the sample leaking out
- 316 stainless steel with PTFE ball valves and o-rings
- Stainless steel sample release device included, to minimize loss of volatiles during transfer to the sample container
- Trigger on the top check ball regulates how quickly the sample drains from the bailer
- Diameters of 0.5", 1", 1.5" and 2"; standard lengths of 2 ft, 3 ft and 4 ft
- Needs no costly or hard to transport ancillary equipment
- Model 103 Tag Line recommended as the support line, with laser marked cable or laser marked flat tape on an easy to use reel
- Can be disassembled and decontaminated before taking the next sample
Benefits
- High quality samples: representative samples of groundwater from specific depths
- No mixing: sample biases due to mixing with water from different levels in the well are minimized
- No purge water: purging and disposal of purge water can be avoided
- Cost effective: a simple and cost effective device for aquifer profiling
- Easy to transport and use: ideal for point source sampling in hard to access locations
- Reusable: can be decontaminated before taking the next sample
Specifications
MODEL 429 POINT SOURCE BAILER |
|
Construction | 316 stainless steel with PTFE ball valves and o-rings |
Valves | Dual ball valves, top and bottom |
Outside diameters | 0.5" (12.7 mm), 1.0" (25.4 mm), 1.5" (38.1 mm) and 2.0" (50.8 mm) |
Standard lengths | 2 ft (610 mm), 3 ft (910 mm) and 4 ft (1220 mm) |
Sample release | Stainless steel sample release device included, to minimize loss of volatiles during transfer to the sample container |
Support line | Model 103 Tag Line recommended: laser marked cable (marked every 1/4 ft or 5 cm) or laser marked flat tape (marked every 1/100 ft or each mm), mounted on an easy to use reel |
CAPACITY, 2 FT (610 MM) LENGTH |
|
0.5" (12.7 mm) | 1.7 oz (50 ml) |
1.0" (25.4 mm) | 7 oz (210 ml) |
1.5" (38.1 mm) | 13 oz (390 ml) |
2.0" (50.8 mm) | 29 oz (850 ml) |
CAPACITY, 3 FT (910 MM) LENGTH |
|
0.5" (12.7 mm) | 2.7 oz (80 ml) |
1.0" (25.4 mm) | 11 oz (330 ml) |
1.5" (38.1 mm) | 23 oz (680 ml) |
2.0" (50.8 mm) | 47 oz (1390 ml) |
CAPACITY, 4 FT (1220 MM) LENGTH |
|
0.5" (12.7 mm) | 3.7 oz (110 ml) |
1.0" (25.4 mm) | 15 oz (450 ml) |
1.5" (38.1 mm) | 33 oz (970 ml) |
2.0" (50.8 mm) | 65 oz (1930 ml) |
Drawing

Downloads
| 429 Point Source Bailer Datasheet (EN) | Download429 Point Source Bailer Datasheet (EN) |
|---|---|
| 429 Point Source Bailer Operating Instructions - 2" dia. | Download429 Point Source Bailer Operating Instructions - 2" dia. |
| 429 Point Source Bailer Operating Instructions - 1.5", 1" & 0.5" dia. | Download429 Point Source Bailer Operating Instructions - 1.5", 1" & 0.5" dia. |
Related Products
.jpg)
Solinst
401 Waterloo Multilevel System
Solinst 401 Waterloo Multilevel System: modular casing with ports and permanent packers for groundwater samples and head measurements from many isolated zones…
Learn More
Solinst
403 CMT Multilevel Systems
Solinst 403 CMT Multilevel System: continuous multichannel tubing for depth-discrete groundwater monitoring of up to 7 zones in a single well.
Learn More
Solinst
425 Discrete Interval Samplers
Stainless steel Discrete Interval Samplers for no-purge groundwater sampling.
Learn More.jpg)
Solinst
404 Inertial Pump
Solinst 404 Inertial Pump: a simple riser tube and footvalve pump, operated by hand or surface pumping mechanism, to 200+ ft (60+ m) in 0.4" to 6" ID wells.
Learn More