WETEC

Eureka

Fluorescein Sensors


Fluorometric sensors for measuring fluorescein dye in water tracing studies.

  • Range: 0 to 150 ppb
  • Resolution 0.01, linearity of 0.99 R²
  • Sensor life of 5+ years
  • Installs in Manta+ multiprobes or stand-alone on the Trimeter
Quantity
1

Overview

Solinst Eureka Fluorescein Sensors are fluorometric sensors for water quality sondes, used to measure fluorescein dye added to water systems to provide water discharge and velocity data. Fluorescein was the first fluorescent dye used for water tracing work, and is still used for detection by fluorometers and for qualitative (visual) studies of underground contamination of wells. The sensor emits light at a certain wavelength and looks for a very specific, different wavelength in return, reporting directly proportional to the concentration of the dye in the sample. It can be installed in Manta+ multiprobes alongside other sensors, or stand-alone on the Trimeter.

Typical applications

  • Providing water discharge and velocity data with dye tracing studies
  • Flow measurements and circulation, dispersion and plume studies
  • Masking, hydraulic model studies and underground water studies
  • Qualitative (visual) studies of underground contamination of wells
  • Studying and modeling surface and groundwater systems
  • Tracing contaminants in emergency response situations
  • Detecting leaks
  • Measuring tank retention times

Key Features

  • Fluorometric sensor: emits light at a certain wavelength and looks for a very specific, different wavelength in return
  • Range: 0 to 150 ppb
  • Resolution 0.01, linearity of 0.99 R², units in ppb
  • Calibration with a lab-qualified sample
  • Maintenance: cleaning and calibration
  • Sensor life of 5+ years
  • Installs in Manta+ multiprobes alongside other sensors such as additional fluorometers, turbidity, dissolved oxygen, pH and conductivity, or stand-alone on the Trimeter
  • Controlled by the Manta Control software, like other installed sensors
  • Anti-fouling options: universal wiper system and copper mesh sensor guard
  • Trimeter with internal battery pack for self-powered logging is a popular configuration for short and long term dye trace studies
  • Probes can be configured with battery packs for autonomous self-powered deployment, used with field displays for site-to-site spot checking, or connected to data telemetry stations for real-time remote monitoring

Benefits

  • Ultra-low concentrations: Fluorometers allow researchers to measure ultra-low concentrations of dye.
  • On-site measurement: Fluorescein is easily and accurately measured on-site with a portable field-ready fluorometer such as the Manta+.
  • Easy to follow: Fluorescein emits a brilliant green fluorescence, which gives an excellent visual or photographic contrast against the backgrounds normally encountered in water transport studies, so it is easy to visualize the progress of an experiment.
  • Variations of the dye: Small shifts in excitation and emission between fluorescein compounds shouldn't greatly affect the signal, especially if the compound used in the study is the same one used to calibrate the instrument.
  • No dedicated fluorometer needed: The sensor can be installed in a Manta+ probe along with other sensors.
  • Easy operation: The sensor is controlled by the Manta Control software, like other installed sensors.
  • Long sensor life: Typical sensor life is 5+ years.

Specifications

SPECIFICATIONS

 

Sensor type

Fluorescence
Medium sensor

Range

0 to 150 ppb

Resolution

0.01

Accuracy

Linearity of 0.99 R²

Units

ppb

Calibration

Lab-qualified sample

Maintenance

Cleaning and calibration

Sensor life

5+ years

pH

Fluorescence drops very sharply at pH values below 5.5. For optimum results, pH should be between 6 and 10.

Anti-fouling options

Universal wiper system, copper mesh sensor guard

Compatible probes

Manta+ multiprobes, alongside other sensors such as additional fluorometers, turbidity, dissolved oxygen, pH and conductivity
Trimeter, if only fluorescein monitoring is required

Caution

Never look directly at a fluorometer sensor. The UV rays emitted by the sensor can cause eye damage.

Downloads