LPPYRHE16 Spectrally Flat Class B Pyrheliometer for Direct Solar Irradiance Measurement

  • Direct solar irradiance measuring range of 0…2000 W/m²

  • Spectrally Flat Class B according to ISO 9060:2018, meeting WMO requirements

  • Thermopile sensor with 200…4000 nm spectral range

  • 5° field of view, 1° slope angle and response time <9 s

  • Passive mV, 4…20 mA, 0…1 V, 0…5 V, 0…10 V or RS485 Modbus-RTU outputs, depending on model

  • Factory calibrated and supplied with an individual calibration report

Quantity
1

Overview

The Senseca LPPYRHE16 series comprises Spectrally Flat Class B pyrheliometers according to ISO 9060:2018, designed to measure direct solar irradiance in W/m² while meeting WMO requirements. Each instrument uses a thermopile sensor with a matt black coating and protective quartz window, providing a spectral range (50%) of 200…4000 nm. The series features a measuring range of 0…2000 W/m², a 5° field of view, a 1° slope angle and a response time (95%) of less than 9 seconds.

Depending on the model, available outputs include passive mV, 2-wire 4…20 mA, 0…1 V, 0…5 V, 0…10 V, RS485 Modbus-RTU or combined RS485 Modbus-RTU and 4…20 mA. A built-in passive temperature compensation circuit minimises sensitivity variations caused by temperature changes. The receiving surface must be positioned perpendicular to the sun's rays, using a solar tracker or another suitable alignment method. Each pyrheliometer is factory calibrated and supplied with an individual calibration report.

Typical Applications

  • Direct solar irradiance measurement and monitoring

  • Solar energy research

  • Photovoltaic system performance analysis

  • Climate studies requiring direct solar radiation data

  • Integration into solar monitoring networks and stand-alone measurement systems

Key Features

  • Spectrally Flat Class B classification according to ISO 9060:2018, meeting WMO requirements

  • Thermopile sensor with matt black coating

  • Direct solar irradiance measuring range of 0…2000 W/m²

  • Spectral range (50%) of 200…4000 nm

  • 5° field of view and 1° slope angle

  • Response time (95%) <9 s

  • Protective quartz window against dust and water

  • Built-in passive temperature compensation circuit

  • Passive mV, 2-wire 4…20 mA, 0…1 V, 0…5 V, 0…10 V, RS485 Modbus-RTU or combined RS485 Modbus-RTU and 4…20 mA outputs, depending on model

  • Front and rear flange holes for solar alignment

  • Aluminium housing with operating temperature range of −40…+80 °C

  • Factory calibrated and supplied with an individual calibration report

Benefits

  • Standards-compliant direct solar irradiance measurement with Spectrally Flat Class B performance

  • Faster measurement response with a response time (95%) of less than 9 seconds

  • Flexible output options for integration into different monitoring systems

  • Reduced sensitivity variation through passive temperature compensation

  • Protection against dust and water with a quartz window

  • Easier solar alignment using front and rear flange holes

  • Reduced risk of internal condensation with a silica-gel cartridge

  • Factory calibration with an individual calibration report for traceability

Specifications

Measurement

Measured quantity

Direct solar irradiance

Sensor

Thermopile

Sensor coating

Matt black paint

Measuring range

0…2000 W/m²

Typical sensitivity

5 µV/(W/m²)

Spectral range (50%)

200…4000 nm

Viewing angle

5° (slope 1°)

 

 

Performance According to ISO 9060:2018

Classification

Spectrally Flat Class B

Response time (95%)

<9 s

Zero offset in response to a 5 K/h change in ambient temperature

< |±3| W/m²

Long-term instability (1 year)

< |±1| %

Non-linearity

< |±0.5| %

Spectral error

< |±0.8| %

Temperature response

< |±2| %

Tilt response

< |±0.5| %

 

 

Model

Output

LPPYRHE16

Passive mV

LPPYRHE16AC

2-wire (current loop) 4…20 mA

LPPYRHE16ACS

RS485 Modbus-RTU + analog 4…20 mA

LPPYRHE16AV

0…10 V

LPPYRHE16AV1

0…1 V

LPPYRHE16AV5

0…5 V

LPPYRHE16S

RS485 Modbus-RTU

 

 

Electrical

Passive mV model power supply

Not required

RS485 output power supply

5…30 Vdc

Analog output power supply (except 0…10 V)

10…30 Vdc

0…10 V output power supply

15…30 Vdc

Passive mV output impedance

Typically <50 Ω

Recommended reading instrument resolution (passive mV model)

1 µV

4…20 mA load resistance

≤500 Ω

Voltage output load resistance

≥100 kΩ

Electrical connection

4-pole or 8-pole M12 connector, depending on model

 

 

RS485 Modbus-RTU Communication

Communication interface

RS485

Communication protocol

Modbus-RTU

Modbus address range

1…247

Default Modbus address

1

Configurable baud rates

9600, 19200, 38400, 57600, 115200 bps

Default baud rate

19200 bps

Data bits

8

Available communication formats

8N1, 8N2, 8E1, 8E2, 8O1, 8O2

Default communication format

8E1

Default waiting time after transmission

3.5 characters

RS485 output isolation

Not isolated

 

 

Mechanical and Environmental

Material

Aluminium

Sensor window

Quartz

Weight

Approximately 1.5 kg

Operating temperature

−40…+80 °C

Operating relative humidity

0…100 %RH

Internal moisture protection

Silica-gel cartridge

Alignment arrangement

Front and rear flange holes

 

 

Drawing dimension

Value

Overall length

324 mm

First labelled axial dimension

50 mm

Second labelled axial dimension

205 mm

Third labelled axial dimension

60 mm

Cylindrical body diameter

38 mm

Front-view horizontal dimension

84 mm

Front-view vertical dimension

95 mm

 

 

Installation and Calibration

Required orientation

Receiving surface perpendicular to the sun's rays

Positioning method

Solar tracker or another suitable method

Alignment verification

Sunlight passing through the front flange hole reaches the rear flange hole

Factory calibration

Individually factory calibrated

Calibration documentation

Individual calibration report

Recommended calibration check

Annually

 

 

Supplied Accessories

Light shade

Supplied

Silica-gel cartridge

Supplied

Spare silica-gel sachets

3

M12 female free connector

Supplied if the optional cable is not ordered

Calibration report

Supplied

Installation cables

Ordered separately

Drawing

LPPYRHE16 Pyrheliometer Drawing

Downloads

LPPYHRE16 Family Datasheet DownloadLPPYHRE16 Family Datasheet
LPPYRHE16 Family User Manual DownloadLPPYRHE16 Family User Manual
LPPYRHE16 Family CE Declaration of Conformity DownloadLPPYRHE16 Family CE Declaration of Conformity