Senseca
LPPYRHE16 Pyrheliometer
LPPYRHE16 Spectrally Flat Class B Pyrheliometer for Direct Solar Irradiance Measurement
Direct solar irradiance measuring range of 0…2000 W/m²
Spectrally Flat Class B according to ISO 9060:2018, meeting WMO requirements
Thermopile sensor with 200…4000 nm spectral range
5° field of view, 1° slope angle and response time <9 s
Passive mV, 4…20 mA, 0…1 V, 0…5 V, 0…10 V or RS485 Modbus-RTU outputs, depending on model
Factory calibrated and supplied with an individual calibration report
Overview
The Senseca LPPYRHE16 series comprises Spectrally Flat Class B pyrheliometers according to ISO 9060:2018, designed to measure direct solar irradiance in W/m² while meeting WMO requirements. Each instrument uses a thermopile sensor with a matt black coating and protective quartz window, providing a spectral range (50%) of 200…4000 nm. The series features a measuring range of 0…2000 W/m², a 5° field of view, a 1° slope angle and a response time (95%) of less than 9 seconds.
Depending on the model, available outputs include passive mV, 2-wire 4…20 mA, 0…1 V, 0…5 V, 0…10 V, RS485 Modbus-RTU or combined RS485 Modbus-RTU and 4…20 mA. A built-in passive temperature compensation circuit minimises sensitivity variations caused by temperature changes. The receiving surface must be positioned perpendicular to the sun's rays, using a solar tracker or another suitable alignment method. Each pyrheliometer is factory calibrated and supplied with an individual calibration report.
Typical Applications
Direct solar irradiance measurement and monitoring
Solar energy research
Photovoltaic system performance analysis
Climate studies requiring direct solar radiation data
Integration into solar monitoring networks and stand-alone measurement systems
Key Features
Spectrally Flat Class B classification according to ISO 9060:2018, meeting WMO requirements
Thermopile sensor with matt black coating
Direct solar irradiance measuring range of 0…2000 W/m²
Spectral range (50%) of 200…4000 nm
5° field of view and 1° slope angle
Response time (95%) <9 s
Protective quartz window against dust and water
Built-in passive temperature compensation circuit
Passive mV, 2-wire 4…20 mA, 0…1 V, 0…5 V, 0…10 V, RS485 Modbus-RTU or combined RS485 Modbus-RTU and 4…20 mA outputs, depending on model
Front and rear flange holes for solar alignment
Aluminium housing with operating temperature range of −40…+80 °C
Factory calibrated and supplied with an individual calibration report
Benefits
Standards-compliant direct solar irradiance measurement with Spectrally Flat Class B performance
Faster measurement response with a response time (95%) of less than 9 seconds
Flexible output options for integration into different monitoring systems
Reduced sensitivity variation through passive temperature compensation
Protection against dust and water with a quartz window
Easier solar alignment using front and rear flange holes
Reduced risk of internal condensation with a silica-gel cartridge
Factory calibration with an individual calibration report for traceability
Specifications
Measurement | |
|---|---|
Measured quantity | Direct solar irradiance |
Sensor | Thermopile |
Sensor coating | Matt black paint |
Measuring range | 0…2000 W/m² |
Typical sensitivity | 5 µV/(W/m²) |
Spectral range (50%) | 200…4000 nm |
Viewing angle | 5° (slope 1°) |
Performance According to ISO 9060:2018 | |
|---|---|
Classification | Spectrally Flat Class B |
Response time (95%) | <9 s |
Zero offset in response to a 5 K/h change in ambient temperature | < |±3| W/m² |
Long-term instability (1 year) | < |±1| % |
Non-linearity | < |±0.5| % |
Spectral error | < |±0.8| % |
Temperature response | < |±2| % |
Tilt response | < |±0.5| % |
Model | Output |
|---|---|
LPPYRHE16 | Passive mV |
LPPYRHE16AC | 2-wire (current loop) 4…20 mA |
LPPYRHE16ACS | RS485 Modbus-RTU + analog 4…20 mA |
LPPYRHE16AV | 0…10 V |
LPPYRHE16AV1 | 0…1 V |
LPPYRHE16AV5 | 0…5 V |
LPPYRHE16S | RS485 Modbus-RTU |
Electrical | |
|---|---|
Passive mV model power supply | Not required |
RS485 output power supply | 5…30 Vdc |
Analog output power supply (except 0…10 V) | 10…30 Vdc |
0…10 V output power supply | 15…30 Vdc |
Passive mV output impedance | Typically <50 Ω |
Recommended reading instrument resolution (passive mV model) | 1 µV |
4…20 mA load resistance | ≤500 Ω |
Voltage output load resistance | ≥100 kΩ |
Electrical connection | 4-pole or 8-pole M12 connector, depending on model |
RS485 Modbus-RTU Communication | |
|---|---|
Communication interface | RS485 |
Communication protocol | Modbus-RTU |
Modbus address range | 1…247 |
Default Modbus address | 1 |
Configurable baud rates | 9600, 19200, 38400, 57600, 115200 bps |
Default baud rate | 19200 bps |
Data bits | 8 |
Available communication formats | 8N1, 8N2, 8E1, 8E2, 8O1, 8O2 |
Default communication format | 8E1 |
Default waiting time after transmission | 3.5 characters |
RS485 output isolation | Not isolated |
Mechanical and Environmental | |
|---|---|
Material | Aluminium |
Sensor window | Quartz |
Weight | Approximately 1.5 kg |
Operating temperature | −40…+80 °C |
Operating relative humidity | 0…100 %RH |
Internal moisture protection | Silica-gel cartridge |
Alignment arrangement | Front and rear flange holes |
Drawing dimension | Value |
|---|---|
Overall length | 324 mm |
First labelled axial dimension | 50 mm |
Second labelled axial dimension | 205 mm |
Third labelled axial dimension | 60 mm |
Cylindrical body diameter | 38 mm |
Front-view horizontal dimension | 84 mm |
Front-view vertical dimension | 95 mm |
Installation and Calibration | |
|---|---|
Required orientation | Receiving surface perpendicular to the sun's rays |
Positioning method | Solar tracker or another suitable method |
Alignment verification | Sunlight passing through the front flange hole reaches the rear flange hole |
Factory calibration | Individually factory calibrated |
Calibration documentation | Individual calibration report |
Recommended calibration check | Annually |
Supplied Accessories | |
|---|---|
Light shade | Supplied |
Silica-gel cartridge | Supplied |
Spare silica-gel sachets | 3 |
M12 female free connector | Supplied if the optional cable is not ordered |
Calibration report | Supplied |
Installation cables | Ordered separately |
Drawing

Downloads
| LPPYHRE16 Family Datasheet | DownloadLPPYHRE16 Family Datasheet |
|---|---|
| LPPYRHE16 Family User Manual | DownloadLPPYRHE16 Family User Manual |
| LPPYRHE16 Family CE Declaration of Conformity | DownloadLPPYRHE16 Family CE Declaration of Conformity |
Related Products

Senseca
LPPIRG01 Pyrgeometer
Pyrgeometer for far infrared radiation measurement and energy balance studies.
Learn MoreSenseca
LPSILICON-PYRA04 Silicon Pyranometer
Silicon pyranometer for global solar irradiance measurement in solar thermal and PV applications.
Learn More
Senseca
LPS13 Class A Pyranometer with Shadow Ring
Spectrally Flat Class A pyranometer with adjustable shadow ring for diffuse solar irradiance measurement.
Learn More
Senseca
LPS12 Class B pyranometer with Shadow Ring
Spectrally Flat Class B pyranometer with adjustable shadow ring for diffuse solar irradiance measurement.
Learn More