Senseca
LPRAD01 Radiometric Probe
Radiometric probe for indoor VIS-NIR irradiance measurement.
- Measures irradiance from 0…200 mW/cm2 across ≈400 nm…≈1050 nm
- Passive mV output, no external power supply
- Individually calibrated, with a 5 m cable
Overview
The Senseca LPRAD01 is a radiometric probe that measures irradiance, defined as the radiant energy flow (W) crossing a surface divided by the surface area (m2), in the VIS-NIR spectral region from ≈400 nm to ≈1050 nm. It is suitable for indoor applications that need constant radiometric monitoring, and it comes in a compact Ø 30 mm x 38 mm housing with a 5 m cable.
The probe needs no external power supply. The photodiode current is converted into a potential difference through a resistor, read in mV with a voltmeter, and the irradiance value is calculated with the calibration factor marked on the probe housing. Each probe is individually calibrated, using the 577/579 nm lines of a Xe-Hg lamp filtered through a special interferential filter. The output signal can also be converted to 4…20 mA or 0…10 Vdc using compatible HD978TR series converters.
Typical applications
- Indoor VIS-NIR irradiance monitoring
- Indoor applications that require constant radiometric monitoring
Key Features
- VIS-NIR irradiance measurement, ≈400 nm…≈1050 nm
- Measuring range 0…200 mW/cm2
- Typical sensitivity 2.6 µV/µW/cm-2
- Calibration accuracy <6%
- Passive mV output, no external power supply needed
- Individually calibrated, with the calibration factor marked on the housing
- Compact Ø 30 mm x 38 mm housing with 5 m cable
- Output convertible to 4…20 mA or 0…10 Vdc with HD978TR series converters
Benefits
- Simple setup: passive mV output with no external power supply
- Wide VIS-NIR coverage from ≈400 nm to ≈1050 nm for indoor irradiance monitoring
- Each probe has its own calibration factor marked on the housing, for direct calculation of the measured value
- Compact housing and 5 m cable make it easy to integrate into measurement setups
Specifications
MEASUREMENT |
|
Measured quantity | Irradiance |
Typical sensitivity | 2.6 µV/µW/cm-2 |
Measuring range | 0…200 mW/cm2 |
Spectral range | ≈400 nm…≈1050 nm |
ACCURACY |
|
Calibration accuracy | <6% |
Cosine response / directional error (f2) | <6% |
Calibration method | 577/579 nm lines of a Xe-Hg lamp, filtered through a special interferential filter |
OUTPUT |
|
Output signal | Passive mV signal from the photodiode with shunt resistor |
Output impedance | 1 kΩ |
Signal conversion | Can be converted to 4…20 mA or 0…10 Vdc using HD978TR series converters |
Reading instrument | Digital multimeter with input resistance >100 kΩ for 1% reading precision |
POWER REQUIREMENT |
|
Power supply | Not required (passive output) |
ENVIRONMENTAL |
|
Operating temperature | 0…50°C |
Application | Indoor use |
MECHANICAL |
|
Dimensions | Ø 30 mm x 38 mm height |
Cable length | 5 m |
Downloads
| dsh_fam_LPxx01_en (2) | Downloaddsh_fam_LPxx01_en (2) |
|---|
Related Products

Senseca
LPUVA01 UVA Radiometric Probe
UVA irradiance probe for indoor monitoring, measuring 0…200 mW/cm² in the 315–400 nm range with a passive mV output, blind to visible and infrared light.
Learn More
Senseca
LPPHOT01 Photometric Probe
Class B illuminance probe for indoor lux monitoring, reading 0…200 klux with V(λ) spectral response and a cosine-corrected diffuser.