Senseca
LPS03 Class C Pyranometer
Spectrally Flat Class C thermopile pyranometer for global solar irradiance measurement and monitoring.
Measuring range −200…4000 W/m² and spectral range 300…2800 nm
ISO 9060:2018 classification and factory calibration according to ISO 9847:2023
RS485 Modbus-RTU, configurable analog, 2-wire 4…20 mA or passive mV outputs (model-dependent)
IP67 protection with integrated bubble level for horizontal positioning
Overview
The Senseca LPS03 series comprises Spectrally Flat Class C pyranometers designed to measure global solar irradiance on a flat surface, including direct and diffuse solar radiation. Based on the thermopile measuring principle, the pyranometers cover a measuring range of −200…4000 W/m² and a spectral range of 300…2800 nm. Classified according to ISO 9060:2018, they are suitable for research, meteorology and photovoltaic (PV) monitoring.
Depending on the model, the LPS03 pyranometers provide RS485 Modbus-RTU, configurable analog, 2-wire 4…20 mA or passive mV outputs. Digital models incorporate internal temperature, relative humidity and pressure sensors for monitoring operating conditions, with tilt sensing available on selected models. The instruments feature an integrated bubble level and adjustable feet for horizontal positioning, along with IP67 protection, an anodized aluminium housing, an ASA protection screen and an optical glass dome. Each pyranometer is factory calibrated according to ISO 9847:2023 (Type A1) and supplied with an individual calibration report.
Typical Applications
Global solar irradiance measurement for scientific research
Solar radiation monitoring in meteorological applications
Photovoltaic (PV) solar irradiance monitoring
Key Features
Spectrally Flat Class C classification according to ISO 9060:2018
Thermopile sensor for global solar irradiance measurement
Measuring range −200…4000 W/m²
Spectral range (50%) 300…2800 nm
Resolution 0.1 W/m²
Response time (95%) < 18 s
RS485 Modbus-RTU, configurable analog (4…20 mA, 0…20 mA, 0…1 V, 0…5 V or 0…10 V), 2-wire 4…20 mA or passive mV outputs (model-dependent)
Internal temperature, relative humidity and pressure diagnostic sensors (LPS03Mxx models)
Optional tilt sensor (LPS03M0T and LPS03MAT models)
Integrated bubble level and adjustable feet for horizontal positioning
IP67 protection with anodized aluminium housing, ASA protection screen and optical glass dome
Operating temperature −40…+80 °C
Factory calibrated according to ISO 9847:2023 (Type A1), with individual calibration report
Benefits
Reliable global solar irradiance measurement for research, meteorology and PV monitoring
Flexible output options for integration with different monitoring and data acquisition systems
Easier installation with integrated bubble level and adjustable feet
Continuous monitoring of operating conditions through built-in diagnostic sensors (digital models)
Optional tilt monitoring to help maintain correct sensor positioning
Durable outdoor operation with IP67 protection and weather-resistant materials
Convenient configuration and real-time monitoring using DATAsense software (digital models)
Supplied factory calibrated with an individual calibration report
Specifications
General Measurement | |
|---|---|
Sensor and measuring principle | Thermopile (Seebeck effect) |
Typical sensitivity | 5…15 µV/(W/m²) |
Measuring range | −200…4000 W/m² |
Resolution | 0.1 W/m² |
Viewing angle | 2π sr |
Spectral range (50%) | 300…2800 nm |
Technical According to ISO 9060:2018 | |
|---|---|
Classification | Spectrally Flat Class C |
Response time (95%) | <18 s |
Zero offset — response to 200 W/m² thermal radiation | Magnitude <15 W/m² |
Zero offset — response to 5 K/h ambient temperature change | Magnitude <4 W/m² |
Total zero offset, including the above effects and other sources | Magnitude <20 W/m² |
Long-term instability (1 year) | Magnitude <1% |
Non-linearity | Magnitude <1% |
Directional response (up to 80° with 1000 W/m² beam) | Magnitude <20 W/m² |
Spectral error | Magnitude <1% |
Temperature response (−10…+40 °C) | Magnitude <2% |
Tilt response | Magnitude <1.5% |
Model | Output |
|---|---|
LPS03M00 | Isolated RS485 Modbus-RTU |
LPS03M0T | Isolated RS485 Modbus-RTU |
LPS03MA0 | Isolated RS485 Modbus-RTU + configurable analog output |
LPS03MAT | Isolated RS485 Modbus-RTU + configurable analog output |
LPS030C0 | 2-wire current loop, 4…20 mA |
LPS030P0 | Passive mV |
Configurable Analog Output — LPS03MA0 and LPS03MAT | |
|---|---|
Default analog output | 4…20 mA |
Other selectable outputs | 0…20 mA, 0…1 V, 0…5 V, 0…10 V |
Default analog output irradiance range | 0…2000 W/m² |
Analog output irradiance range | User-configurable |
Electrical | |
|---|---|
Power supply — RS485 output | 7…30 Vdc |
Power supply — analog output (except 0…10 V) | 10…30 Vdc |
Power supply — 0…10 V output | 15…30 Vdc |
Consumption — LPS03M0x | 15 mA at 24 Vdc; 21 mA at 12 Vdc |
Consumption — LPS03MAx | 37 mA at 24 Vdc and Iout = 22 mA; 43 mA at 12 Vdc and Iout = 22 mA |
Connection — except LPS03MAx | 5-pole M12 |
Connection — LPS03MAx | 8-pole M12 |
Internal Diagnostic Sensors — LPS03Mxx Models (Internal Temperature) | |
|---|---|
Measuring range | −40…+80 °C |
Resolution | 0.1 °C |
Accuracy | ±0.5 °C (0…60 °C) |
Internal Diagnostic Sensors — LPS03Mxx Models (Internal Relative Humidity) | |
|---|---|
Measuring range | 0…100% RH |
Resolution | 0.1% RH |
Accuracy | ±3% RH at 25 °C (20…80% RH) |
Internal Diagnostic Sensors — LPS03Mxx Models (Internal Pressure) | |
|---|---|
Measuring range | 300…1100 hPa |
Resolution | 0.1 hPa |
Accuracy | ±1 hPa (0…60 °C) |
Tilt Sensor — LPS03M0T and LPS03MAT Models | |
|---|---|
Measuring range | 0…180° |
Resolution | 0.1° |
Accuracy | <0.5° |
Environmental and Mechanical | |
|---|---|
Operating temperature | −40…+80 °C |
Operating relative humidity | 0…100% RH |
Maximum operating altitude | 6000 m |
Protection degree | IP67 |
Housing material | Anodized aluminium |
Protection screen material | ASA |
Dome material | Optical glass |
Dome outer diameter | 32 mm |
Dome thickness | 4 mm |
Weight | Approximately 230 g |
Bubble level accuracy | <0.2° |
Mean time between failures (MTBF) | >10 years |
Calibration and Other Standards | |
|---|---|
Calibration standard | ISO 9847:2023 (Type A1) |
Calibration method | Comparison with a reference pyranometer |
Reference calibration | Reference sample calibrated annually at WRC (World Radiation Center) |
Calibration documentation | Individual calibration report supplied |
Additional certification | ISO 17025 Calibration Certificate available upon request |
Other stated compliance | WMO recommendations and IEC 61724-1 requirements |
Configuration and Monitoring — LPS03Mxx Models | |
|---|---|
PC application software | DATAsense |
Sensor configuration | Modbus parameters and analog output measuring range |
Measurement monitoring | Real-time monitoring, including graphical irradiance display |
Data recording | Measurement values can be saved to a file during connection |
Additional monitoring function | Built-in days-of-operation counter |
Drawing

Downloads
| LPS03 Family Datasheet | DownloadLPS03 Family Datasheet |
|---|---|
| LPS03 Family User Manual | DownloadLPS03 Family User Manual |
| LPS03 Family CE Declaration of Conformity | DownloadLPS03 Family CE Declaration of Conformity |
Related Products

Senseca
LPS02 Class B Pyranometer
Spectrally Flat Class B pyranometer for global solar irradiance monitoring.
Learn More
Senseca
LPS10 Class A Pyranometer
Spectrally Flat Class A pyranometer for accurate global solar irradiance monitoring.
Learn More
Senseca
LPR10 Class A Pyranometer
Fast Response Spectrally Flat Class A pyranometer for global solar irradiance measurement. Thermopile sensor with
Learn More
Senseca
LPPYRA-Lite Class C Pyranometer
Compact Class C thermopile pyranometer for PV and solar monitoring.
Learn More