Senseca
LPSD18 Sunshine Duration Sensor
LPSD18 Sunshine Duration Sensor
Measures sunshine status and duration using the WMO direct solar radiation threshold of 120 W/m².
16 silicon photodiodes, 0…2000 W/m² direct solar radiation range and 1 s sunshine duration resolution.
RS485 Modbus-RTU, SDI-12, galvanically isolated contact and 0…1 V voltage outputs, depending on model.
IP66 protection with anti-condensation heating and optional antifreeze heating.
Overview
The Senseca LPSD18 is a sunshine duration sensor designed to measure sunshine status, duration and direct solar radiation according to the World Meteorological Organization (WMO) definition, using a direct solar radiation threshold of 120 W/m². It uses an array of 16 silicon photodiodes to measure direct solar radiation from 0…2000 W/m², with a sunshine duration resolution of 1 s. Its design eliminates mechanical moving parts, ensuring long-term reliability without requiring seasonal positioning adjustments.
The LPSD18 is available in three versions: LPSD18.1 with RS485 Modbus-RTU and galvanically isolated contact output; LPSD18.2 with RS485 Modbus-RTU, 0…1 V analog and digital voltage outputs; and LPSD18.3 with SDI-12 and galvanically isolated contact output. The sensor operates on a 7…30 Vdc power supply and features IP66 protection. A separately powered anti-condensation heating element prevents condensation on the glass surface, while optional antifreeze heating helps prevent ice formation and snow accumulation in harsh weather conditions.
Typical Applications
Sunshine duration and direct solar radiation monitoring
Agricultural research and crop growth studies
Photovoltaic system performance verification
Building automation for automatic blinds and shutters
Sunlight presence detection for general monitoring applications
Key Features
16 silicon photodiodes for sunshine detection and direct solar radiation measurement
Direct solar radiation measuring range of 0…2000 W/m²
WMO sunshine detection threshold of 120 W/m²
Sunshine duration resolution of 1 s
Spectral range of 360…1100 nm
Response time of less than 1 ms
RS485 Modbus-RTU, SDI-12, galvanically isolated contact or 0…1 V analog and digital outputs, depending on model
No mechanical moving parts or seasonal positioning adjustments required
IP66 protection for outdoor operation
Separately powered anti-condensation heating with optional antifreeze heating
Operating temperature range of −40…+80 °C
7…30 Vdc power supply
Optional flat-base or Ø 40 mm mast supports with inclination adjustment up to 80°
Benefits
Sunshine duration and direct solar radiation measurement from one sensor
Reliable long-term operation without mechanical moving parts or seasonal positioning adjustments
Flexible output options for integration with different monitoring systems
Anti-condensation heating with optional antifreeze heating to prevent ice formation and snow accumulation
IP66 protection for outdoor monitoring applications
Cost-effective alternative to a pyrheliometer without requiring a solar tracker
Specifications
Sunshine Detection and Measurement | |
|---|---|
Sensitive elements | 16 silicon photodiodes |
Spectral range | 360…1100 nm |
Direct radiation (SRD) measuring range | 0…2000 W/m² |
Direct radiation measurement accuracy | Better than 90% on the monthly total |
Sunshine duration measurement accuracy | Better than 90% on the monthly total |
Response time | <1 ms |
Sunshine detection threshold | 120 W/m² |
Sunshine duration resolution | 1 s |
Electrical | |
|---|---|
Power supply | 7…30 Vdc |
Current consumption | 5 mA at 12 V |
Heating System | |
|---|---|
Heating system power supply | 12…15 Vdc |
Anti-condensation heating | Separately powered and galvanically isolated |
Anti-condensation device consumption | 1 W at 12 V |
Optional antifreeze heating | Second heating element, option R (LPSD18.xR) |
Antifreeze device consumption | 5 W at 12 V |
Antifreeze heating activation | ON when internal temperature < 6 °C |
Antifreeze heating deactivation | OFF when internal temperature > 10 °C |
Temperature | |
|---|---|
Internal temperature measuring range | −40…+80 °C |
Internal temperature measurement accuracy | ±0.5 °C |
Operating temperature | −40…+80 °C |
Mechanical and Environmental | |
|---|---|
Weight | 0.9 kg |
Protection degree | IP66 |
Model | Output Configuration |
|---|---|
LPSD18.1 | RS485 Modbus-RTU and galvanically isolated contact |
LPSD18.2 | RS485 Modbus-RTU, 0…1 V analog output and 0…1 V digital voltage output |
LPSD18.3 | SDI-12 and galvanically isolated contact |
Contact and Voltage Output Characteristics | |
|---|---|
Galvanically isolated contact – Closed | SRD ≥ 120 W/m² |
Galvanically isolated contact – Open | SRD < 120 W/m² |
Analog voltage output | 0…1 V corresponding to 0…2000 W/m² |
Digital voltage output – 1 V | SRD ≥ 120 W/m² |
Digital voltage output – 0 V | SRD < 120 W/m² |
RS485 Modbus-RTU Communication | |
|---|---|
Communication protocol | RS485 Modbus-RTU |
Modbus address range | 1…247 |
Factory preset address | 1 |
Selectable baud rates | 9600 or 19200 bps |
Factory preset baud rate | 19200 bps |
Supported serial configurations | 8N1, 8N2, 8E1, 8E2, 8O1, 8O2 |
Factory preset serial configuration | 8E1 |
Waiting time after transmission | Immediate reception or 3.5-character waiting time |
Factory preset waiting time | 3.5 characters |
SDI-12 Communication | |
|---|---|
Communication protocol | SDI-12 version 1.3 |
Baud rate | 1200 bps |
Data bits | 7 |
Parity | Even |
Stop bits | 1 |
Factory preset address | 0 |
Installation | |
|---|---|
Installation methods | Flat base or vertical mast using optional supports |
Flat-base support | LPSD18.O |
Mast support | LPSD18.VK |
Compatible mast diameter | Ø 40 mm |
Maximum inclination adjustment | 80° relative to vertical |
Flat-base levelling | Two adjustable feet and one fixed foot |
Mast support adjustment | Inclination and rotation in the horizontal plane |
Seasonal positioning adjustment | Not required |
Connection | |
|---|---|
Instrument connector | 8-pole M12 male connector |
Optional connection cable | CP18… |
Cable termination | 8-pole M12 connector on one end and open wires on the other |
Available cable lengths | 5 m (CP18.5) and 10 m (CP18.10) |
Optional Accessories Ordering Code | |
|---|---|
LPSD18.O | Base for installation on a horizontal plane, with two adjustable feet and one fixed foot; allows inclination up to 80° from vertical |
LPSD18.VK | Support for installation on a Ø 40 mm mast; allows inclination up to 80° from vertical and rotation in the horizontal plane |
LPSG | Cartridge for silica-gel crystals with O-ring |
LPG | Pack of 5 silica-gel cartridges |
Model | |
|---|---|
LPSD18.1R | LPSD18.1 with optional antifreeze heating |
LPSD18.2R | LPSD18.2 with optional antifreeze heating |
LPSD18.3R | LPSD18.3 with optional antifreeze heating |
Downloads
| LPSD18 Family Datasheet | DownloadLPSD18 Family Datasheet |
|---|---|
| LPSD18 Family User Manual | DownloadLPSD18 Family User Manual |
| LPSD18 Family CE Declaration of Conformity | DownloadLPSD18 Family CE Declaration of Conformity |
Related Products

Senseca
LPUVA02 UVA radiometer
UVA radiometer for outdoor global irradiance and indoor UVA monitoring.
Learn More
Senseca
LPUVA03 Radiometric Probe
UVA irradiance probe for outdoor monitoring.
Learn More
Senseca
LPPYRHE16 Pyrheliometer
Class B pyrheliometer for direct solar irradiance measurement.
Learn More
Senseca
LPPIRG01 Pyrgeometer
Pyrgeometer for far infrared radiation measurement and energy balance studies.
Learn More