WETEC

Senseca

LPUVA02 UVA radiometer


LPUVA02 UVA radiometer for outdoor global irradiance and indoor UVA emission monitoring.

  • Measures global UVA irradiance from 0…200 W/m²

  • Solid-state sensor with peak spectral response at 365 nm

  • Passive mV, 4…20 mA, 0…1 V, 0…5 V or 0…10 V outputs

  • 50 mm protective dome with diffuser and housing designed for cosine-law response

  • Individually factory-calibrated with a unique calibration factor

  • Operating temperature: −40…+80 °C

Quantity
1

Overview

The Senseca LPUVA02 is a UVA radiometer designed to measure global irradiance on a flat surface, combining direct solar and diffuse UVA radiation. It covers a measuring range of 0…200 W/m² and is suitable for outdoor UVA monitoring and indoor UVA emission measurements. The instrument uses a solid-state sensor with dedicated optical filters, providing a peak spectral response at 365 nm.

The radiometer features a 50 mm diameter dome that protects the sensor from weather elements, while its diffuser and housing provide a response close to the cosine law. It is available with passive mV output (LPUVA02), 4…20 mA output (LPUVA02AC), or voltage outputs of 0…1 V (LPUVA02AV1), 0…5 V (LPUVA02AV5) and 0…10 V (LPUVA02AV). The passive version requires no external power supply, while active versions operate on 10…30 Vdc or 15…30 Vdc, depending on the model. Each radiometer is individually factory-calibrated with its own calibration factor and operates within a temperature range of −40…+80 °C.

Typical Applications

  • Outdoor global UVA irradiance monitoring

  • Indoor UVA emission monitoring

  • UVA irradiance data acquisition using passive mV, current or voltage outputs

Key Features

  • Solid-state sensor with dedicated optical filters for UVA spectral response

  • Global UVA irradiance measuring range of 0…200 W/m²

  • Peak spectral response at 365 nm

  • Cosine-law directional response with deviation <8% (0…80°)

  • Fast response time <0.5 s (95%)

  • 50 mm outer diameter dome for protection against weather elements

  • Passive mV, 4…20 mA, 0…1 V, 0…5 V or 0…10 V output options

  • 4-pole M12 electrical connector

  • Operating temperature range of −40…+80 °C

  • Silica-gel cartridge to minimise condensation inside the dome

  • Levelling device supplied for accurate horizontal positioning

  • Individually factory-calibrated with a unique calibration factor

Benefits

  • Measures direct and diffuse solar UVA irradiance on a flat surface

  • Suitable for both outdoor monitoring and indoor UVA emission measurement

  • Multiple output versions to suit different data acquisition systems

  • Passive version requires no external power supply

  • Individually factory-calibrated with a documented calibration factor

  • Protective dome shields the sensor from weather elements

  • Silica-gel cartridge helps prevent condensation inside the dome

  • Cosine-law response supports measurement at low sun elevations

  • Fast response time for monitoring changes in UVA irradiance

Specifications

UVA Measurement

Measuring principle

Solid-state sensor with optical filters

Measured quantity

Global UVA irradiance (direct solar and diffuse irradiance)

Measuring range

0…200 W/m²

Viewing range

2π sr

Typical sensitivity (passive version)

70…200 µV/(W/m²)

Response time

<0.5 s (95%)

Directional response (cosine law)

<8% (0…80°)

Long-term instability (1 year)

<3% in absolute value

Non-linearity

<1% in absolute value

Temperature response

<0.1%/°C

 

 

Spectral

Spectral range (1/2)

342…384 nm

Spectral range (1/10)

330…393 nm

Spectral range (1/100)

320…400 nm

Peak spectral response

365 nm

 

 

Model

Output

Power supply

LPUVA02

Passive mV

Not required

LPUVA02AC

4…20 mA, 2-wire

10…30 Vdc

LPUVA02AV1

0…1 V

10…30 Vdc

LPUVA02AV5

0…5 V

10…30 Vdc

LPUVA02AV

0…10 V

15…30 Vdc

 

 

Additional Electrical

Active analogue output irradiance range

0…200 W/m²

Output impedance (passive version)

Approx. 3 kΩ

Typical passive output signal

Does not exceed 50 mV

Recommended reading instrument resolution (passive version)

1 µV

Maximum load resistance (LPUVA02AC)

500 Ω

Minimum load resistance (voltage versions)

100 kΩ

Electrical connection

4-pole M12 connector

Out-of-range output (LPUVA02AC)

22 mA

Out-of-range output (voltage versions)

10% above full scale

 

 

Mechanical and Environmental

Protective dome outer diameter

50 mm

Dome function

Protection of sensor from weather elements

Operating temperature

−40…+80 °C

Weight

Approx. 900 g

Fixing holes

M5 (32 mm interaxis) or M8 (65 mm interaxis)

Horizontal positioning

Bubble level integrated into the radiometer; two lower feet adjustable using hex ring nuts

Condensation control

Silica-gel cartridge

 

 

Calibration

Calibration

Individually factory-calibrated

Calibration method

Comparison with the primary standard of the Senseca metrology laboratory

Calibration light source

Suitably filtered Xe-Hg lamp

Calibration wavelength

365 nm

Calibration factor

Individual factor indicated on the instrument and in the Calibration Report

Recommended calibration check

Annually

 

 

Standard Supplied Accessories

Shade disk

Included

Silica-gel cartridge

Included

Spare silica-gel sachets

2 sachets

Levelling device

Included

Calibration Report

Included

M12 female free connector

Included if an optional cable is not ordered

 

 

Optional Accessories Ordering code

LPS1

Fixing bracket for Ø30…50 mm mast; installation on horizontal or vertical mast

CPM12AA4.5

4-pole M12 cable with open wires, 5 m

CPM12AA4.10

4-pole M12 cable with open wires, 10 m

 

 

Spare Parts Ordering code

LPSP1

UV-resistant solar radiation protection screen

LPG

Silica-gel, 5 sachets

LPSG

Desiccant cartridge complete with O-ring and cap

Drawing

LPUVA02 UVA radiometer Drawing

Downloads

LPUVA02 Family Datasheet DownloadLPUVA02 Family Datasheet
LPUVA02 Family User Manual DownloadLPUVA02 Family User Manual
LPUVA02 Family CE Declaration of Conformity DownloadLPUVA02 Family CE Declaration of Conformity