BARANI DESIGN
MeteoTemp RH+T Temperature & Humidity Probe
2-in-1 WMO temperature and humidity probe with ultra-low power consumption.
Temperature, humidity, dew point and frost point outputs
800 µA power consumption eliminates self-heating
RS485 Modbus-RTU / ASCII with 3-stage lightning protection
Overview
The BARANI MeteoTemp RH+T is a 2-in-1 meteorological sensor probe that outputs air temperature, relative humidity, dew point and frost point. It meets WMO requirements for accurate air temperature, humidity and long-term stability. Its ultra-low combined power consumption of 800 µA, often 5x less than other meteorological probes, eliminates the self-heating error that can reach over +0.2 °C with other sensors.
Temperature is measured from -45 to +105 °C with ± 0.10 °C accuracy between 0 and +65 °C, and humidity across 0…100 %RH. A replaceable, self-cleaning PTFE filter cap keeps the sensing elements clean and speeds humidity recovery after rain. Output is RS485 with Modbus-RTU or ASCII protocol, with 3-stage lightning, surge and ESD protection. Calibration coefficients are stored in the sensor for easy recalibration and traceability. Combined with the helical MeteoShield, MeteoTemp achieves some of the lowest air temperature uncertainties available.
Typical applications
Meteorology and weather stations
Airports
Agriculture
Hydrology
Road management and roadside sensors
Buoy and marine
Ships
Coastal sites
Polar and winter sites
Ski lift and snow making
Smart cities
Industrial SCADA and PLC systems
Key Features
Temperature, humidity, dew point and frost point outputs
Meets WMO requirements for air temperature and humidity
± 0.10 °C temperature accuracy (0…+65 °C)
Ultra-low 800 µA power consumption with no self-heating
Replaceable, self-cleaning PTFE filter cap
Corrosion-resistant, hydrophobic white sensor body
RS485 output with Modbus-RTU or ASCII protocol
3-stage lightning, surge, transient and ESD protection
Calibration coefficients stored in the sensor
Waterproof bayonet locking connector
SDI-12 version available on special order
Benefits
Low measurement uncertainty for accurate air temperature
Extends weather station battery life
Smaller solar panel for lower weather station cost
Quick humidity recovery after rain or wave impact on buoys
Fast sensor response through the high pore-density filter cap
Easy recalibration and long-term traceability
Specifications
TEMPERATURE |
|
Sensor type | Silicon |
Measuring range | -45…+105 °C |
Accuracy | ± 0.10 °C (0…+65 °C); below 0 °C increases linearly to ± 0.20 °C at -45 °C; ± 0.20 °C maximum over full range |
Resolution | 0.01 °C |
Stability | < 0.02 °C per year |
Response time | 5…30 s (τ63%, excludes filter-cap effects) |
Meets WMO | Yes |
RELATIVE HUMIDITY |
|
Sensor type | Capacitive |
Measuring range | 0…100 %RH |
Accuracy (0…80 %RH) | -45…0 °C: ± 3.95 → ± 2.05 %RH; 0…+25 °C: ± 2.05 → ± 1.30 %RH; +25…+50 °C: ± 1.30 → ± 2.05 %RH |
Accuracy (80…100 %RH) | Add ± 0.025 %RH for each 1 %RH above 80 %RH (up to + 0.50 %RH at 100 %RH) |
Hysteresis | Short-term ≤ ± 1.0 %RH additional |
Resolution | 0.01 %RH |
Stability | < 0.25 %RH per year |
Response time | 8…30 s (τ63%, excludes filter-cap effects) |
Meets WMO | Yes |
DEW POINT / FROST POINT |
|
Accuracy (calculated at 90 %RH) | ± 0.39 °C DPw at +25 °C; ± 0.46 °C DPw / ± 0.40 °C FPi at 0 °C; road-NaCl reference: ± 0.44 °C FPi at -7 °C |
Resolution | 0.01 °C |
Output range | Calculated, dependent on temperature and RH |
Response time | 8…30 s |
Meets WMO | Yes |
OUTPUTS |
|
Digital output | RS485 with Modbus-RTU or ASCII protocol |
Connection | Bayonet connector with silicone O-ring |
Cable wiring | White = GND; Brown = VCC; Green = A (non-inverting); Yellow = B (inverting) |
POWER REQUIREMENT |
|
Power supply | 5…24 Vdc with reverse polarity protection (startup in-rush < 100 mA for 1 ms) |
Power consumption | 800 µA at 1 Hz output incl. RS485 communication; 25 µA quiescent |
PROTECTION |
|
Lightning and surge protection | 3-stage, per IEC EN 61000-4-2, EN 61000-4-4, EN 61000-4-5 on both data and power lines; Surge, EFT/Burst |
Surge test | 4 kV / 2 kA acc. to EN50082-2 / IEC61000-6-2 |
ESD | 15 kV |
ENVIRONMENTAL |
|
Operating conditions | -45…+105 °C / 0…100 %RH |
Protection degree | IP66W (DIN 40050) |
MECHANICAL |
|
Dimensions | Length 133 mm (164 mm with mating connector); Ø 16 mm base; Ø 12 mm PTFE sensor cap |
Filter cap | Replaceable screw-on PTFE (Teflon) filter cap |
Sensor body | Corrosion-resistant, hydrophobic white body |
CALIBRATION |
|
Calibration equation | From a simple offset value up to x⁴ calibration equation |
Coefficients | Up to 9 significant digits, stored in the sensor; read out and programmed via Modbus |
Drawing

Downloads
| MeteoTemp-RH-T-Datasheet-EN | DownloadMeteoTemp-RH-T-Datasheet-EN |
|---|
Related Products

BARANI DESIGN
FARS MeteoShield Pro Fan-Aspirated Radiation Shield
Solar-powered fan-aspirated helical radiation shield for climatic reference air temperature.
Learn More
BARANI DESIGN
MeteoShield Professional Radiation Shield
Patented double-helix solar radiation shield for air temperature and humidity sensors. 0.1 °C mean overheating, no fan needed, keeps sensors clean.
Learn More
BARANI DESIGN
MeteoPressure MSB181 Barometric Pressure Sensor
WMO-compliant barometric pressure sensor in an all-metal housing.
Learn More
BARANI DESIGN
MeteoTemp RH+T+PRESSURE 3-in-1 Probe
3-in-1 probe for air temperature, humidity and barometric pressure with dew and frost point.
Learn More