BARANI DESIGN
MeteoWind 2 Anemometer & Wind Vane
Compact anemometer with wind vane, exceeding WMO and MEASNET Class 1 accuracy.
0…80 m/s wind speed and 0…360° direction, sampled at 10 Hz
RS485 Modbus-RTU / ASCII output with 3-stage lightning protection
Optional 20 W heater for winter reliability
Overview
The BARANI MeteoWind 2 is a compact anemometer with a wind vane that exceeds WMO and MEASNET Class 1 accuracy standards for meteorology and wind resource assessment. Its patented elliptical cups create more torque and high linearity than conical cups, giving very low starting speeds, fast response and accurate long-term wind data. It is certified for aviation use per ICAO and WMO guidelines.
Wind speed (0…80 m/s) and wind direction (0…360°, no dead-spot) are both sampled at 10 Hz to accurately capture wind gusts. Output is RS485 with user selectable Modbus-RTU or ASCII protocol, with 3-stage lightning, surge and ESD protection built in. The all-metal anodized aluminium body, fiber reinforced cups and oversize ball bearings give high dirt and weather resistance. A heated version adds up to 20 W of body and bearing heating for cold winter climates.
Typical applications
Wind resource assessment
Meteorology and weather stations
Airports
Road management and winter maintenance
Agriculture
Hydrology
Buoy and marine
Ships
Coastal sites
Polar and winter sites
Ski lift and snow making
Smart cities
Industrial and PLC systems
Key Features
Combined anemometer and wind vane in one compact sensor
Exceeds WMO and MEASNET Class 1 accuracy standards
0…80 m/s wind speed, 0…360° wind direction with no dead-spot
10 Hz sampling rate to accurately capture wind gusts
Patented flat elliptical cups for low start-up speed and high linearity
Dual-arm reinforced cups with oversize ball bearings
All-metal anodized aluminium body and replaceable all-metal wind vane
RS485 output with user selectable Modbus-RTU or ASCII
3-stage lightning, EMC, surge and ESD protection
Weatherproof locking bayonet connector
Remotely adjustable north for simplified installation
Optional 20 W heater with manual or automatic control
Benefits
Two instruments for the price of one
Lower power requirement than two separate instruments
One sensor and one mount, with less cable and fewer connections
Reduced installation time and simpler data logger configuration
Long maintenance intervals thanks to high dirt, dust and sand resistance
Serviceable rotor bearing, cups and wind vane
Superb snow shedding for reliable winter operation, even without heating
Specifications
WIND SPEED |
|
Measuring range | 0…80 m/s (gust) |
Resolution | 0.01 m/s |
Accuracy | < 1% or < ± 0.2 m/s (the greater of), or ± 0.05 m/s (4…16 m/s) with MEASNET calibration |
Sampling rate | 10 Hz @ 3 pulses per revolution |
Starting wind speed | < 0.3 m/s |
Distance constant (delay distance) | 1.7 m (per ASTM D 5096-96) |
Linearity | R² > 0.99995 MEASNET / IEC 61400-12-1:2005 |
Tilt angle sensitivity | Cosine response (horizontal wind speed measurement) |
WIND DIRECTION |
|
Measuring range | 0…360° |
Resolution | 1° |
Accuracy | 2° (no dead-spot) |
Sampling rate | 10 Hz |
Starting wind speed | < 0.2 m/s |
CALIBRATION |
|
Default linearity constants, cups before 2023 | m/s = 0.43 × (Hz) + 0.33 |
Default linearity constants, dendriform cups 2023+ | m/s = 0.4360 × (Hz) + 0.3500 for ± 0.2 m/s; or quadratic linearization: m/s = -0.00020 × (Hz)² + 0.4470 × (Hz) + 0.3000 for ± 0.15 m/s |
OUTPUTS |
|
Digital output | RS485 with Modbus-RTU and ASCII protocol (user selectable) |
Connection | Weatherproof locking bayonet connector with silicone O-ring |
POWER REQUIREMENT |
|
Power supply | 5…24 Vdc with inrush protection and reverse polarity protection |
Power consumption | 2.6 mA @ 12 V (combined wind speed and direction at 10 Hz sampling, incl. RS485 communication) |
Heater (optional) | 20 W (1.1 A) @ 24 Vdc (5 W @ 12 Vdc); user selectable manual or automatic heater control |
PROTECTION |
|
Lightning and surge protection | 3-stage, per IEC EN 61000-4-5 on both data and power lines; Surge, EFT/Burst |
Surge test | 4 kV / 2 kA acc. to EN50082-2 / IEC61000-6-2 |
ESD | 15 kV |
ENVIRONMENTAL |
|
Operating conditions | -40…+80 °C / 0…100 %RH |
Survival wind speed | > 90 m/s (324 kph, 200 mph) |
Protection degree | IP65W (DIN 40050) |
MECHANICAL |
|
Housing material | All-metal anodized aluminium body, fiber reinforced plastic (FRP) cups, all-metal wind vane |
Dimensions | Rotor diameter Ø 164 mm; wind vane radius 136 mm; total height 320 mm |
Weight | approx. 300 g (without stainless steel mount) |
Mounting | Two M4 screws with supplied holder |
Anemometer holder | Ø 20 mm (1.5 mm wall) stainless steel tube |
Patented / registered | OHIM 002153882-0001, 002153882-0002, 002153882-0003 |
Drawing

Downloads
| MeteoWind 2 Datasheet (EN) | DownloadMeteoWind 2 Datasheet (EN) |
|---|
Related Products

BARANI DESIGN
FARS MeteoShield Pro Fan-Aspirated Radiation Shield
Solar-powered fan-aspirated helical radiation shield for climatic reference air temperature.
Learn More
BARANI DESIGN
MeteoShield Professional Radiation Shield
Patented double-helix solar radiation shield for air temperature and humidity sensors. 0.1 °C mean overheating, no fan needed, keeps sensors clean.
Learn More
BARANI DESIGN
MeteoPressure MSB181 Barometric Pressure Sensor
WMO-compliant barometric pressure sensor in an all-metal housing.
Learn More
BARANI DESIGN
MeteoTemp RH+T+PRESSURE 3-in-1 Probe
3-in-1 probe for air temperature, humidity and barometric pressure with dew and frost point.
Learn More