Senseca
PU4SK Pressure Transmitter for Industrial Pressure Monitoring
Universal pressure transmitter and pressure switch with a robust ceramic strain-gauge measuring cell for industrial applications.
Measuring ranges from 250 mbar to 600 bar
Accuracy as high as ±0.15% FSO (Xcellence version)
4…20 mA FSK, RS485 Modbus®-RTU, IO-Link® or 0…10 V outputs
Process temperature −40…+135 °C (extended version)
Fully welded stainless steel housing with IP69K/IP67 protection
Available with flush-mounted or internal diaphragm
Overview
The Precont® PU4SK is a universal electronic pressure transmitter and pressure switch designed for monitoring, controlling and continuously measuring pressure in gases, vapors, liquids and dusts. It features a robust ceramic Al₂O₃ (96%) strain-gauge measuring cell, with measuring ranges from 250 mbar to 600 bar and accuracy as high as ±0.15% FSO with the Xcellence version. It is available with flush-mounted or internal diaphragms.
The transmitter offers multiple output options, including 4…20 mA FSK, RS485 Modbus®-RTU, IO-Link® and 0…10 V, together with various process and electrical connections. Its fully welded stainless steel housing provides IP69K/IP67 protection, while the extended temperature version supports process temperatures from −40 to +135 °C. Flush-mounted versions support CIP/SIP cleaning processes, and ATEX/IECEx certification is available for selected configurations.
Typical Applications
Pressure monitoring in machinery and industrial equipment
Pressure measurement in hydraulic and pneumatic systems
Pressure monitoring in HVAC and refrigeration systems
Process pressure measurement and control in industrial plants
Pressure monitoring in environmental technology systems
Pressure measurement in facility and building automation systems
Key Features
Robust ceramic Al₂O₃ (96%) strain-gauge measuring cell
Measuring ranges from 250 mbar to 600 bar
Accuracy as high as ±0.15% FSO (Xcellence version)
Relative pressure and absolute pressure versions (absolute: 1…40 bar)
Flush-mounted or internal measuring diaphragm
Standard process temperature range −40…+100 °C or extended range −40…+135 °C
4…20 mA FSK, RS485 Modbus®-RTU, IO-Link® or 0…10 V outputs
Response time (t90) ≤ 2 ms with RS485 Modbus®-RTU or IO-Link®
Fully welded stainless steel housing with IP69K/IP67 protection
Wide selection of process connections
M12 or EN 175-301-803 angled electrical connectors
CIP/SIP cleaning compatibility for flush-mounted versions
Optional ATEX/IECEx certification for selected configurations
Optional factory calibration with calibration certificate
Benefits
Precise pressure measurements with long-term stability
Versatility across low- to high-pressure industrial applications
Flexible integration into control and monitoring systems through multiple output options
Adaptable installation through various process and electrical connections
Durability under demanding environmental conditions, including shock and vibration
Simplified cleaning and reduced maintenance with CIP/SIP-compatible flush-mounted versions
Suitability for hazardous environments with selected ATEX/IECEx-certified configurations
Specifications
Measuring System | |
|---|---|
Device type | Universal pressure transmitter / pressure switch |
Measured parameter | Pressure |
Measuring media | Gases, vapors, liquids and dusts |
Measuring principle | Thick-film strain-gauge measuring cell |
Diaphragm configuration | Flush-mounted or internal diaphragm |
Pressure type | Relative (gauge) or absolute pressure |
Relative Pressure Measuring Ranges | Overload Pressure |
|---|---|
0…250 mbar | 0.75 bar |
0…400 mbar | 1.2 bar |
0…600 mbar | 1.8 bar |
0…1 bar | 3 bar |
0…1.6 bar | 6 bar |
0…2.5 bar | 6 bar |
0…4 bar | 15 bar |
0…6 bar | 15 bar |
0…10 bar | 20 bar |
0…16 bar | 40 bar |
0…25 bar | 40 bar |
0…40 bar | 100 bar |
0…60 bar | 100 bar |
0…100 bar | 200 bar |
0…160 bar | 400 bar |
0…250 bar | 400 bar |
0…320 bar | 800 bar |
0…400 bar | 800 bar |
0…600 bar | 900 bar |
−1…0 bar | 3 bar |
−1…+1 bar | 6 bar |
Absolute Pressure Measuring Ranges | Overload Pressure |
|---|---|
0…1 bar | 3 bar |
0…1.6 bar | 6 bar |
0…2.5 bar | 6 bar |
0…4 bar | 15 bar |
0…6 bar | 15 bar |
0…10 bar | 20 bar |
0…16 bar | 40 bar |
0…25 bar | 40 bar |
0…40 bar | 100 bar |
Measuring Accuracy | |
|---|---|
Measuring resolution | ≥ 16 bits (FSI) |
Characteristic curve deviation – Standard | ≤ ±0.5% FSI |
Characteristic curve deviation – Xcellence | ≤ ±0.15% FSI |
Hysteresis | ≤ ±0.1% FSI |
Repeatability | ≤ ±0.1% FSI |
Temperature influence | Tk ≤ ±0.05% FSI/K |
Auxiliary power influence | ≤ ±0.002% FSI/V |
Mounting orientation influence | ≤ 0.2 mbar (vertical position, sensor at the top) |
Electronic Output – Type A (4…20 mA FSK) | |
|---|---|
Output configuration | 2-wire |
Nominal analogue output | 4…20 mA |
Signal range | 3.9…20.5 mA |
Error signal | ≤ 3.9 mA / ≥ 20.5 mA |
Communication interface | FSK |
Transmission rate | 1200 bit/s |
External coupling resistance | ≥ 240 Ω |
Output resolution | ≤ 1 µA |
Permissible load resistance (RL) | ≤ (Us − 9 V) / 20.5 mA |
Minimum response time (t90-min) | ≤ 5 ms (td = 0 s) |
Auxiliary power influence | ≤ ±0.5 µA/V |
Ambient temperature influence | ≤ ±1 µA/K |
Electronic Output – Type B (0…10 V) | |
|---|---|
Output configuration | 3-wire |
Nominal analogue output | 0…10 V |
Signal range | 0…10.25 V |
Error signal | 0 V / ≥ 10.25 V |
Output resolution | ≤ 1 mV |
Permissible load resistance (RL) | ≥ Uo / 2 mA |
Minimum response time (t90-min) | ≤ 5 ms (td = 0 s) |
Auxiliary power influence | ≤ ±0.5 mV/V |
Ambient temperature influence | ≤ ±1 mV/K |
Electronic Output – Type V (RS485 Modbus®-RTU) | |
|---|---|
Output configuration | 4-wire |
Communication interface | Bidirectional RS485 Modbus®-RTU |
Transmission rate | 9600 baud (4800…38400 baud) |
Input resistance | 112 kΩ |
Minimum response time (t90-min) | ≤ 2 ms (td = 0 s) |
Communication Interface | |
|---|---|
Output configuration | 4-wire |
IO-Link version | V1.1 |
Port classification | Class A |
Communication rate | COM2: 38.4 kBaud; COM3: 230.4 kBaud |
Cycle time | ≥ 2.3 ms |
Minimum response time (t90-min) | ≤ 2 ms (td = 0 s), applicable to communication, switching and analogue outputs |
Switching Output | |
|---|---|
Switching output | 2 × push-pull (PP) |
Switching direction | +L / −L |
Output voltage (Uo) | ≤ 0.2 V / ≥ (Us − 2 V) |
Output current (Io) | 0…200 mA |
Current limitation | ≤ 450 mA |
Short-circuit protection | Yes |
Switching delay time | ≤ 30 µs (RL ≤ 3 kΩ / Io ≥ 4.5 mA) |
Switching cycles | ≥ 100 million |
Analogue Output | |
|---|---|
Analogue output | 1 × current output, 4…20 mA or 0…20 mA |
Signal range (4…20 mA) | 3.8…20.5 mA |
Error signal (4…20 mA) | ≤ 3.6 mA / ≥ 21 mA (22 mA) |
Signal range (0…20 mA) | 0…20.5 mA |
Error signal (0…20 mA) | ≤ 0.05 mA / ≥ 21 mA (22 mA) |
Output resolution | ≤ 1 µA |
Permissible load resistance (RL) | ≤ (Us − 8 V) / 22 mA |
Auxiliary power influence | ≤ ±0.5 µA/V |
Ambient temperature influence | ≤ ±0.5 µA/K |
Electronic Version | Supply Voltage (Us) | Input Current (Is) |
|---|---|---|
Type A – 4…20 mA FSK | 9…35 Vdc | ≤ 20.5 mA |
Type A – 4…20 mA FSK (Ex) | 9…30 Vdc | ≤ 22 mA |
Type B – 0…10 V | 14…35 Vdc | ≤ 25 mA (Io = 0 mA) |
Type V – RS485 Modbus®-RTU | 6…35 Vdc | ≤ 10 mA (Cio = 0 mA) |
Type L – IO-Link® inactive | 9…35 Vdc | ≤ 20 mA (Cio / So / Io = 0 mA) |
Type L – IO-Link® active | 18…30 Vdc | ≤ 20 mA (Cio / So / Io = 0 mA) |
Process Conditions | |
|---|---|
Standard process temperature | −40…+100 °C |
Extended process temperature | −40…+135 °C, with temperature decoupler |
EPDM gasket temperature | −40…+140 °C |
Process temperature – ATEX/IECEx versions | According to the applicable certificate |
Pressure cycles | ≥ 100 million (1.2 × PN) |
CIP/SIP cleaning compatibility | Flush-mounted versions |
Environmental Conditions | |
|---|---|
Ambient temperature – Standard version | −40…+100 °C |
Ambient temperature – ATEX/IECEx versions | According to the applicable certificate |
Ingress protection | IP69K/IP67 (EN/IEC 60529) |
Climate class | 4K4H (EN/IEC 60721-3-4) |
Shock resistance | 50 g, 11 ms (EN/IEC 60068-2-27) |
Vibration resistance | 20 g, 10…2000 Hz (EN/IEC 60068-2-6) |
Electromagnetic compatibility (EMC) | Equipment Class B / Industrial environment (EN/IEC 61326) |
Dielectric strength | 500 Vac |
Electrical protection class | III |
Pollution degree | 4 |
Operating altitude | 2000 m above sea level |
Mean Time to Failure (MTTF) | |
|---|---|
Type A – 4…20 mA FSK | 745 years |
Type B – 0…10 V | 610 years |
Type V – RS485 Modbus®-RTU | 561 years |
Type L – IO-Link® | 601 years |
Process Connections Order Code | |
|---|---|
3 | ISO 228-1 – G¼″ A, ISO 1179-2 E |
6 | ISO 228-1 – G¼″ A, EN 837 (manometer) |
4 | ISO 228-1 – G¼″ I, internal thread |
1 | ISO 228-1 – G½″ A, EN 837 (manometer) |
2 | ISO 228-1 – G½″ A, ISO 1179-2 E, internal drill |
8 | ISO 228-1 – G¾″ A, ISO 1179-2 E, front-flush |
5 | ISO 228-1 – G1″ A, ISO 1179-2 E, front-flush |
E | ANSI NPT ¼″ |
C | ANSI NPT ½″ |
Y | Other process connections |
Electrical Connections | |
|---|---|
S | M12 × 1 plug |
C | EN 175-301-803-C plug (DIN 43650-C) |
A | EN 175-301-803-A plug (DIN 43650-A) |
Output and Connector Compatibility | |
|---|---|
Type A – 4…20 mA FSK | S, C, A |
Type B – 0…10 V | C, A |
Type V – RS485 Modbus®-RTU | S |
Type L – IO-Link® | S |
Materials and Mechanical Construction | |
|---|---|
Process-wetted diaphragm | Al₂O₃ ceramic (96%) |
Process-wetted connection | Stainless steel 1.4404/316L or 1.4571/316Ti |
Process gasket options | FPM/FKM (e.g. Viton®), FDA-listed EPDM or other materials |
Housing construction | Fully welded stainless steel |
Terminal enclosure material | CrNi steel |
Non-process-wetted materials | CrNi steel, PUR, PA, acrylic copolymer, FKM/FPM, NBR |
Weight | 0.2…0.5 kg |
Approvals and Compliance | |
|---|---|
RoHS Directive | 2011/65/EU |
General Product Safety Regulation (GPSR) | Regulation (EU) 2023/988 |
EMC Directive | 2014/30/EU |
ATEX Directive | 2014/34/EU (Ex-marked versions only) |
ATEX gas approval | II 1 G |
ATEX dust approval | II 1 D |
IECEx gas protection | Ex ia IIC Ga |
IECEx dust protection | Ex ia IIIC Da |
ATEX/IECEx configuration | Electronic output Type A with electrical connection S only |
EU type examination certificate | TÜV 17 ATEX 212257 X-00 |
Additional Options Order code | |
|---|---|
SF | LABS-free, silicone-free / paint-compatible version |
ML | Measurement point designation / TAG laser marking |
MZ | Material test certificate – EN 10204 3.1 |
WT | Factory certification – drinking water suitability |
KF | Configuration / presetting |
WK | Factory calibration with calibration certificate |
Drawing

Downloads
| PU4SK Datasheet | DownloadPU4SK Datasheet |
|---|---|
| PU4SK Family User Manual | DownloadPU4SK Family User Manual |
| PU4SK Family CE Declaration of Conformity | DownloadPU4SK Family CE Declaration of Conformity |
Related Products

Senseca
GTF112-RTD M12 Connection Screw-in Resistance Temperature Probe
The GTF112P is a screw-in resistance temperature sensor featuring Pt100 or Pt1000 elements, a stainless steel probe, a 4-pole M12 connector and temperature…
Learn More
Senseca
GTF102-RTD Screw-in Resistance Temperature Probe
The GTF102P is a screw-in resistance temperature probe with Pt100 or Pt1000 sensing elements, a stainless steel protective tube, configurable cable insulation…
Learn More
Senseca
TF1-K Temperature switch
TF1-K compact temperature controller with stainless steel process connection, bimetal thermostat, +40 to +120 °C switching values and IP65 protection for…
Learn More
Senseca
EPS2 Pressure Transmitter with Stainless Steel Membrane
The EPS2 Pressure Transmitter measures relative pressure in liquids and gases, featuring ranges from 0–0.6 to 0–2000 bar, a stainless steel housing, fast…
Learn More