Refined Oil and Fuel Sensors


Fluorometric sensors for rapid in situ detection of refined oils and fuels in water.

  • Range: 0 to 20 ppm
  • Resolution 0.01, linearity of 0.99 R²
  • Sensor life of 5+ years
  • Installs in Manta+ multiprobes or stand-alone on the Trimeter
Quantity
1

Overview

Solinst Eureka Refined Oil and Fuel Sensors are fluorometric sensors for water quality sondes, providing data for rapid in situ detection of refined fuels such as benzene, toluene, ethylbenzene and xylenes (BTEX). These volatile organic compounds (VOCs) are found in petroleum derivatives, and environmental contamination occurs primarily through leakage from broken or degraded storage tanks, pipelines or containers. The sensor suits researchers interested in detecting the presence or absence of VOCs and measuring relative fluorescence changes that can indicate increasing or decreasing concentrations. It can be installed in Manta+ multiprobes alongside other sensors, or stand-alone on the Trimeter.

Typical applications

  • Rapid in situ detection of refined oils and fuels (BTEX) in water
  • Detecting the presence or absence of VOCs
  • Measuring relative fluorescence changes that indicate increasing or decreasing concentrations
  • Monitoring for leakage from storage tanks, pipelines or containers

Key Features

  • Fluorometric sensor using deep UV excitation (<300 nm) and a broadband emission filter for detection between 300 and 400 nm
  • Range: 0 to 20 ppm
  • Resolution 0.01, linearity of 0.99 R², units in ppm
  • Analog signal based on the relative fluorescence intensity of refined oils (fuels) in water, converted to a digital output in the Eureka multiprobe
  • Calibration with a lab-qualified sample or a secondary solid standard ("cal cube")
  • Maintenance: cleaning and calibration
  • Sensor life of 5+ years
  • Installs in Manta+ multiparameter sondes alongside other sensors such as dissolved oxygen, pH, conductivity and additional fluorometers, or on a smaller probe such as the Trimeter
  • Controlled by the Manta Control software, like other installed sensors
  • Anti-fouling options for continuous deployment: universal wiper system and copper mesh sensor guard
  • Probes can be configured with battery packs for autonomous self-powered deployment, used with field displays for site-to-site spot checking, or connected to data telemetry stations for real-time remote monitoring

Benefits

  • Rapid in situ data: Provides data for rapid in situ detection of refined oil and fuel compounds, where quantification in the lab is typically done using gas or liquid chromatography.
  • No dedicated fluorometer needed: The sensor can be installed in a Manta+ probe along with other sensors.
  • Easy operation: The sensor is controlled by the Manta Control software, like other installed sensors.
  • Flexible deployment: Self-powered logging, field displays for spot checking, or data telemetry for real-time remote monitoring.
  • Long sensor life: Typical sensor life is 5+ years.

Specifications

SPECIFICATIONS

 

Sensor type

Fluorescence
Medium sensor

Excitation and emission

Deep UV excitation (<300 nm)
Broadband emission filter, detection between 300 and 400 nm

Range

0 to 20 ppm

Resolution

0.01

Accuracy

Linearity of 0.99 R²

Units

ppm

Calibration

Lab-qualified sample
Secondary solid standard ("cal cube")

Maintenance

Cleaning and calibration

Sensor life

5+ years

Fouling

Foreign material on the active surface can reduce the emitted or received light, or give a false signal by fluorescing at the same wavelengths as the refined oil. Normally a problem only in long-term deployments, not in daily surveys.

Anti-fouling options

Universal wiper system, copper mesh sensor guard

Compatible probes

Manta+ multiprobes, alongside other sensors such as dissolved oxygen, pH, conductivity and additional fluorometers
Trimeter, if only refined oil is required

Caution

Never look directly at a fluorometer sensor. The UV rays emitted by the sensor can cause eye damage.