WETEC
Trimeter Water Quality Sonde thumbnail 1
Trimeter Water Quality Sonde thumbnail 2

Eureka

Trimeter Water Quality Sonde


Compact multiparameter sonde that holds any one Solinst Eureka sensor, plus temperature and depth.

  • Select any one water quality sensor (excluding ISEs, PAR and CO2) and add temperature and/or depth
  • Suited to spot checking, logging or connection to data stations and telemetry
  • Optional battery pack for self-powered logging
Quantity
1

Overview

The Trimeter is Solinst Eureka's most compact multiprobe. It incorporates the electronics of the Solinst Eureka Manta+ multiprobes in a smaller, lightweight instrument body. Select any one Solinst Eureka water quality sensor (excluding ISEs, PAR and CO2) and add temperature and/or depth (vented or non-vented) sensors. Temperature is included for Trimeters with conductivity, pH or DO sensors. Connect it to a field display for sampling in the field, add a battery pack for autonomous deployments, or connect to a telemetry station to view real-time data in the cloud.

Typical applications

  • Environmental monitoring: long-term monitoring to track water quality changes, assessing impacts of runoff, tracking saltwater intrusion
  • Surface water and groundwater sampling: routine water quality checks and assessing aquifer health
  • Industrial discharge monitoring: ensuring compliance and the effectiveness of treatment processes
  • Aquaculture: maintaining optimal water quality conditions for fish and shellfish farming
  • Water and wastewater treatment: optimizing treatment processes and ensuring the quality of treated water
  • Stormwater runoff monitoring: tracking water quality impact and measuring the effectiveness of stormwater management practices
  • Dredging operations: monitoring turbidity to ensure compliance and to protect aquatic habitats
  • Mining operations: monitoring the impact of mining activities on water quality
  • Research and education: conducting water quality research projects
  • Dye-trace studies: equipped with Rhodamine, Fluorescein or other custom dye sensors

Key Features

  • Holds any one Solinst Eureka water quality sensor, plus optional temperature and depth (vented or non-vented) sensors
  • Wipered turbidity sensor, suited to autonomous turbidity logging
  • For spot checking, logging, or connection to data stations and telemetry
  • LED diagnostic status indicators
  • Optional internal battery pack (three "D" size alkaline batteries) or attachable rechargeable Li-ion external battery pack
  • Robust marine connector
  • Small, rugged, lightweight design
  • Compatible with all Solinst Eureka software apps (Windows, iOS and Android) and communication cables
  • 4 Mbytes of memory for logged data, >1,000,000 readings

Benefits

  • Flexible Deployment: Use it for spot checking, logging, or connection to data stations/telemetry.
  • Turbidity Logging: Sensor with built-in wiper, excellent for autonomous turbidity monitoring.
  • Easy to Use: Features LED diagnostic status indicators.
  • Real-time Data: Connect to a powered data station via RS-232, or optional SDI-12 or MODBUS, or view on your smart device with MantaLink.
  • Durable: Small, rugged, and lightweight design with a robust marine connector.
  • Versatile: Compatible with all Solinst Eureka software apps (Windows, iOS, and Android) and communication cables.

Specifications

GENERAL SPECIFICATIONS

 

Sensors

Any one Solinst Eureka water quality sensor (excluding ISEs, PAR and CO2), plus optional temperature and depth (vented or non-vented) sensors
Temperature is included for Trimeters with conductivity, pH or DO sensors

Diameter (OD)

Without external battery pack: 1.95" (5 cm)
With external battery pack: 2.95" (7.5 cm)

Length

Without battery pack: 14" (36 cm)
With internal battery pack: 24.5" (62 cm)
With external battery pack: 23" (58 cm)

Weight

Without battery pack: 1.4 lbs (0.64 kg)
With internal battery pack (with batteries): 2.4 lbs (1.1 kg)
With external battery pack: 3.7 lbs (1.7 kg)

Battery pack options

Internal: holds three 1.5 VDC "D" size replaceable alkaline batteries
External: attachable rechargeable Li-ion battery

Battery life

Logging time dependent on number of sensors, logging interval and temperature

Operating temperature

-5°C to 50°C

Data memory

4 Mbytes for logged data, >1,000,000 readings

Connectivity

Underwater cable or data cable via marine connector
Bluetooth® connectivity via mantaMobile™ device
RS-232, or optional SDI-12 or MODBUS

 

 

SENSOR SPECIFICATIONS

 

Temperature

Range: -5 to 50°C
Resolution: 0.01
Accuracy: ±0.1
Calibration not required

pH

Range: 0 to 14 units
Resolution: 0.01
Accuracy: ±0.1 within 10°C of calibration; or 0.2 otherwise
Refillable reference electrode; corrected for temperature; typical sensor life >6 years

ORP

Range: -999 to 999 mV
Resolution: 0.1
Accuracy: ±20 mV
Optional ORP sensor is combined with pH sensor

Conductivity - specific conductance (µS/cm)

Range: 0 to 5000 µS/cm
Resolution: 0.1
Accuracy: ±0.5% of reading or ±1, whichever is greater
Corrected for temperature; four easy-to-clean graphite electrodes; optional sensor provides ±0.5% of reading accuracy to 100 mS/cm

Conductivity - specific conductance (mS/cm)

Range: 0 to 100 mS/cm; 100 to 275 mS/cm
Resolution: 0.001
Accuracy: ±1% of reading ±0.001 (0 to 100 mS/cm); ±2% of reading (100 to 275 mS/cm)

Conductivity - salinity

Range: 0 to 70 PSU
Resolution: 0.01
Accuracy: ±2% of reading
Calculated from conductivity and temperature; PSU is equivalent to ppt

Conductivity - total dissolved solids (TDS)

Range: 0 to 65 g/l
Resolution: 0.1
Accuracy: ±5% of reading
Calculated from conductivity and temperature

Dissolved oxygen (optical) - concentration

Range: 0 to 20 mg/l, ±0.1; 20 to 30 mg/l, ±0.15; 30 to 50 mg/l, ±5% of reading
Resolution: 0.01
Compensated for temperature and salinity; EPA approved "lifetime" luminescence method; typical sensor cap life >6 years

Dissolved oxygen (optical) - % saturation

Range: 0 to 500% saturation
Resolution: 0.1
Accuracy: corresponds with the accuracy of the concentration reading

Turbidity

Range: 0 to 1000 FNU; 1000 to 4000 FNU
Resolution: 0.01
Accuracy: ±0.3 FNU or ±2% of reading, whichever is greater (0 to 1000 FNU); ±4% of reading (1000 to 4000 FNU)
Filtered for non-turbidity spikes; includes wiper to clean the optics; FNU and NTU are interchangeable

Depth (absolute)

Range: 0 to 25 m, accuracy ±0.05; 0 to 200 m, accuracy ±0.4
Resolution: 0.01
Compensated for temperature and salinity

Depth (vented)

Range: 0 to 10 m
Resolution: 0.001
Accuracy: ±0.003
Compensated for temperature, salinity and barometric pressure

Barometric pressure

Range: 400 to 900 mm Hg
Resolution: 0.1
Accuracy: ±1.5
Included with depth sensor

Total dissolved gas (TDG)

Range: 400 to 1,400 mm Hg
Resolution: 0.1
Accuracy: ±1
Compensated for temperature; maximum depth 15 m

 

 

FLUOROMETERS

 

Resolution and linearity

Resolution: 0.01; linearity of 0.99 R²

Chlorophyll a - blue

0 to 100 µg/l

Chlorophyll a - red

0 to 500 µg/l

Rhodamine dye

0 to 200 ppb

Phycocyanin (freshwater BGA)

0 to 4500 ppb

Phycoerythrin (marine BGA)

0 to 700 ppb

CDOM/FDOM

0 to 500 ppb

Optical brightener

0 to 300 ppb

Tryptophan

0 to 5000 ppb

Fluorescein dye

0 to 150 ppb

PTSA

0 to 650 ppb

Refined oil

0 to 20 ppm

Crude oil

0 to 300 ppb

Caution

Never look directly at a fluorometer sensor. The UV rays emitted by the sensor can cause eye damage.

 

 

SENSOR CONFIGURATION

 

Port numbers (see drawing)

1. Depth (optional)
2. Any single sensor or fluorometer
3. Temperature (optional)

Note

Temperature is included for Trimeters with conductivity, pH or DO sensors

 

 

OPTIONS AND ACCESSORIES

 

Underwater cables

3 to 200 meters in length

Data cable and USB adaptor

Not included

Battery pack

Internal or attachable external battery pack for self-powered logging

mantaMobile™

Provides a Bluetooth® connection to the MantaLink™ app on a mobile device

Other accessories

Soft and hard carry cases, flow cell, anti-fouling sensor guard

Drawing

Trimeter-Water-Quality-Sonde-Diagram

Downloads

Trimeter Water Quality Sonde Datasheet (EN) DownloadTrimeter Water Quality Sonde Datasheet (EN)