Senseca
GEO-MDFS2 Dust Fall Monitoring System
Dust fall monitoring system for evaluating PV panel soiling and determining cleaning requirements.
Dual temperature-compensated Clean and Dirty reference cells for solar radiation comparison.
Solar radiation measurement range of 0…1400 W/m² with ±2.1% measurement error.
65 mV analog output per cell at 1000 W/m².
Basic mode for manual evaluation and advanced mode for automatic attenuation (%) calculation using the MTD-4000 datalogger.
IP65 protection and operating temperature range of -20…+60 °C.
Overview
The Senseca MDFS2 Dust Fall Monitoring System is designed to help solar plant operators determine when photovoltaic (PV) panels require cleaning. It uses two calibrated, temperature-compensated reference cells, designated Clean Cell and Dirty Cell, to compare solar radiation levels. The Clean Cell is kept free of dust, while the Dirty Cell is cleaned alongside the PV panels to assess soiling effects.
The MDFS2 measures solar radiation from 0 to 1400 W/m² with a measurement error of ±2.1% and provides a 65 mV analog output per cell at 1000 W/m². In basic mode, operators manually compare the reference cell readings to evaluate cleaning requirements. In advanced mode, the MTD-4000 datalogger automatically calculates the attenuation percentage due to soiling and records information about cleaning and maintenance activities through the control box. The system features IP65 protection and operates within a temperature range of −20 to +60 °C for outdoor solar plant installations.
Typical Applications
PV panel soiling monitoring in solar power plants
Assessment of PV panel cleaning requirements
Comparison of solar radiation using Clean and Dirty reference cells
Automatic soiling attenuation (%) monitoring with the MTD-4000 datalogger
Confirmation of cleaning and maintenance activities through the control box
Key Features
Dual calibrated, temperature-compensated Clean and Dirty reference cells
Solar radiation measurement range of 0…1400 W/m²
Measurement error of ±2.1%
65 mV analog output per cell at 1000 W/m²
Basic mode for manual comparison of Clean and Dirty Cell readings
Advanced mode for automatic soiling attenuation (%) calculation with the MTD-4000 datalogger
Control box with CLEAN button for cleaning registration and PAIR button for cell pairing
Five data channels: sun elevation, Clean Cell radiation, Dirty Cell radiation, attenuation and MDFS Status Code
9-bit status code for system diagnosis, cleaning and operation alarms
Optional cell pairing routine for more accurate attenuation data in advanced mode
IP65 protection
Operating temperature range of −20…+60 °C
Benefits
Helps determine when PV panels need cleaning based on soiling conditions
Supports efficient cleaning schedules to avoid unnecessary maintenance
Allows manual evaluation of solar radiation without the control box
Provides automatic soiling attenuation (%) calculation with the MTD-4000 datalogger
Helps confirm completed cleaning and maintenance activities
Suitable for outdoor solar plant installations with IP65 protection
Specifications
Radiation Measurement | |
|---|---|
Measurement | Solar radiation |
Reference cells | Two calibrated reference cells (Clean Cell and Dirty Cell) |
Temperature compensation | Yes |
Measurement range | 0…1400 W/m² |
Measurement error | ±2.1% |
Electrical | |
|---|---|
Output type | Analog voltage |
Output signal | 65 mV per output at 1000 W/m² |
Power supply | Not applicable |
Power consumption | Not relevant |
Operating Modes | |
|---|---|
Basic mode | Manual comparison of Clean Cell and Dirty Cell readings to assess cleaning requirements |
Advanced mode | Automatic calculation of attenuation (%) due to soiling using the MTD-4000 datalogger |
Basic mode control box | Not required |
Advanced mode control box | Provides information about field cleaning and maintenance tasks to the datalogger |
Data Channels | Unit | Description |
|---|---|---|
Sun elevation | ° | Sun elevation angle calculated by the DAS in real time |
Clean Solar Cell Radiation | W/m² | Radiation collected by the reference cell designated Clean Cell |
Dirty Solar Cell Radiation | W/m² | Radiation collected by the reference cell designated Dirty Cell |
MDFS Status Code | Binary code | Nine flag bits for system diagnosis and cleaning/operation alarms |
Attenuation | % | Percentage of solar radiation loss due to soiling |
Control Box | |
|---|---|
Digital outputs (buttons) | 2: Clean warning and Pairing instruction |
CLEAN button | Registers Clean Cell cleaning |
PAIR button | Initiates the cell pairing routine |
Pairing indication | LED on the control box |
Control | MTD-4000 datalogger |
Cell Pairing Routine | |
|---|---|
Pairing routine | Optional |
Function | Establishes the initial relationship between Clean Cell and Dirty Cell signals |
PAIR button activation | At least 1 second |
Pairing duration | 60 seconds |
Recommended frequency | Yearly |
Sun elevation condition | Greater than 15° |
Clean Cell radiation condition | Greater than 400 W/m² |
Dirty Cell radiation condition | Greater than 400 W/m² |
Maximum difference between cell readings | 10% |
Dirty Cell reading relative to Clean Cell | Must not exceed Clean Cell radiation by more than 5% |
Attenuation Calculation | |
|---|---|
Calculation | Percentage of solar radiation loss due to soiling |
Solar elevation threshold | Above 15° (factory default) |
Clean Cell radiation threshold | Above 400 W/m² (factory default) |
Output when calculation conditions are not met | Not available or −32000 |
MDFS Status CodeBit | Value | Description |
|---|---|---|
Bit 0 | 1 | PAIR button activation detected |
Bit 1 | 2 | CLEAN button activation detected |
Bit 2 | 4 | Cleaning not detected within the last 7 days (factory default) |
Bit 3 | 8 | Last pairing process failed |
Bit 4 | 16 | Insufficient solar elevation (15° factory-default threshold) |
Bit 5 | 32 | Insufficient solar radiation (400 W/m² factory-default threshold) |
Bit 6 | 64 | Difference between Clean and Dirty Cell signals exceeds the predefined pairing tolerance (±10% factory default) |
Bit 7 | 128 | Number of valid pairing samples below the predefined threshold (10 samples factory default) |
Bit 8 | 256 | Clean Cell radiation considerably below Dirty Cell radiation |
Environmental | |
|---|---|
Operating temperature | −20…+60 °C |
Protection rating | IP65 |
System Components | |
|---|---|
Reference cells | Calibrated, temperature-compensated Clean Cell and Dirty Cell |
Control box | Cleaning task control and pairing process |
Mounting support | Bracket for installation on supporting structures |
Data Acquisition System | MTD-4000 datalogger for advanced operation |
Ordering Information | |
|---|---|
Ordering code | GEO-MDF2 |
Product description | Soiling Measurement System |
Included components | Calibrated dual cell, control box, 25 m cable and SP-101 mounting support |
Downloads
| MDFS2 Family Datasheet | DownloadMDFS2 Family Datasheet |
|---|---|
| MDFS2 Family User Manual | DownloadMDFS2 Family User Manual |
Related Products

Senseca
SEMS-2000 Solar Energy Measurement System
Compact 2-axis solar tracking system for automatic DNI, DHI and GHI monitoring with suitable sensors.
Learn More
Senseca
HDMCS-100 Compact Weather Station
Compact, self-powered automatic weather station for wind, temperature, humidity, pressure and rainfall monitoring.
Learn More
Senseca
VNR 21/22 Conductive Level Signal Amplifier
Signal amplifier for SL series conductive level probes.
Learn More
Senseca
ELECTRA SCV Capacitive Level Switch
Capacitive level switch for liquids, powders and granular materials. No moving parts, PTFE coated electrode, NPN output, 50 bar and lengths up to 1000 mm.
Learn More