Senseca
HD52.3D 2-Axis Ultrasonic Anemometer
2-axis ultrasonic anemometer for wind speed, direction, gust and U-V wind components.
Wind speed 0…60 m/s (0…50 m/s with rain gauge option) and direction 0…359.9°
Built-in magnetic compass for automatic wind direction compensation
Two analog outputs and RS232, RS485, RS422 and SDI-12 serial interfaces
Optional temperature and relative humidity, barometric pressure, and either global solar radiation or rainfall
IP66 protection, optional heating and no moving parts
Overview
The Senseca HD52.3D series consists of 2-axis ultrasonic anemometers designed to measure wind speed, wind direction, wind gusts and U-V Cartesian wind components without moving parts. Wind speed is measured over a range of 0…60 m/s (0…50 m/s with the rain gauge option), while wind direction covers 0…359.9°. A built-in magnetic compass automatically compensates wind measurements and references them to magnetic North, even when the instrument is not aligned to North.
The instruments provide two analog outputs for wind speed and direction, factory-configurable as 4…20 mA (standard), 0…1 V, 0…5 V or 0…10 V. RS232, RS485, RS422 and SDI-12 serial interfaces are available, supporting proprietary ASCII, NMEA, Modbus-RTU and SDI-12 communication protocols. Wind speed and direction averaging intervals are configurable from 1 second to 10 minutes.
Optional measurement features include air temperature and relative humidity, barometric pressure, and either global solar radiation or rainfall, which are mutually exclusive options. The instruments feature IP66 protection, operate on a 10…30 Vdc power supply and support mounting on a Ø 40 mm mast. An optional heater, unavailable on the rain gauge model, prevents snow and ice accumulation on the ultrasonic transducers. The absence of moving parts minimises maintenance requirements.
Typical Applications
Wind speed, direction and gust monitoring in meteorological stations
Wind measurement in fixed and mobile installations
Multi-parameter meteorological monitoring with optional environmental sensors
Remote weather monitoring using photovoltaic panels and backup batteries
Wind data integration with data loggers, PLCs and monitoring networks
Wind measurement in snowy and icy conditions with optional transducer heating
Key Features
2-axis ultrasonic wind measurement without moving parts
Wind speed range 0…60 m/s (0…50 m/s with rain gauge option)
Wind direction range 0…359.9° with 0.1° resolution
Wind gust and U-V Cartesian wind component measurements
Built-in magnetic compass for automatic wind direction compensation
Two analog outputs, factory-configurable as 4…20 mA, 0…1 V, 0…5 V or 0…10 V
RS232, RS485, RS422 and SDI-12 serial interfaces
Proprietary ASCII, NMEA, Modbus-RTU and SDI-12 communication protocols
Configurable wind averaging interval from 1 s to 10 min
Optional temperature and relative humidity, barometric pressure, and either global solar radiation or rainfall measurement
Optional ultrasonic transducer heating to prevent snow and ice accumulation (not available with rain gauge option)
IP66 protection with plastic housing and AISI 316 metal parts
10…30 Vdc power supply (15…30 Vdc required for 0…10 V analog output)
Mounting on Ø 40 mm mast with M23 19-pole electrical connector
Factory-calibrated sensors requiring no field calibration
Benefits
Reduced maintenance requirements with no moving parts
Wind measurements automatically compensated and referenced to magnetic North
Wind speed, direction, gust and U-V components measured by one instrument
Flexible integration with data loggers, PLCs and monitoring systems
Expanded meteorological monitoring with optional environmental sensors
Suitable for remote installations with low power consumption
Factory-calibrated sensors requiring no field calibration
Optional heating prevents snow and ice accumulation on ultrasonic transducers (not available with rain gauge option)
Specifications
Wind Speed | |
|---|---|
Sensor | Ultrasounds |
Measuring range | 0…60 m/s (0…50 m/s with rain gauge option) |
Resolution | 0.01 m/s |
Accuracy | ±0.2 m/s or ±2%, whichever is greater (0…35 m/s); ±3% (above 35 m/s) |
Wind Direction | |
|---|---|
Sensor | Ultrasounds |
Measuring range | 0…359.9° |
Resolution | 0.1° |
Accuracy | ±2° RMSE from 1.0 m/s |
Magnetic Compass | |
|---|---|
Sensor | Magnetic |
Measuring range | 0…360° |
Resolution | 0.1° |
Accuracy | ±1° |
Air Temperature (Optional – Option 17) | |
|---|---|
Sensor | Pt100 |
Measuring range | −40…+70 °C |
Resolution | 0.1 °C |
Accuracy | ±0.15 °C ±0.1% of measurement |
Relative Humidity (Optional – Option 17) | |
|---|---|
Sensor | Capacitive |
Measuring range | 0…100% RH |
Resolution | 0.1% RH |
Accuracy at 15…35 °C | ±1.5% RH (0…90% RH); ±2% RH (remaining range) |
Accuracy at −40…+70 °C | ±(1.5 + 1.5% of measurement)% RH |
Barometric Pressure (Optional – Option 4) | |
|---|---|
Sensor | Piezoresistive |
Measuring range | 300…1100 hPa |
Resolution | 0.1 hPa |
Accuracy at 20 °C | ±0.5 hPa (700…1100 hPa) |
Accuracy at 0…60 °C | ±1 hPa (500…1100 hPa); ±1.5 hPa (300…500 hPa) |
Long-term stability | ±1 hPa/year |
Global Solar Radiation (Optional – Option P) | |
|---|---|
Sensor | Thermopile |
Measuring range | 0…2000 W/m² |
Resolution | 1 W/m² |
Classification | Spectrally Flat Class C |
Rainfall (Optional – Option T) | |
|---|---|
Sensor | Tipping bucket |
Resolution | 0.2 mm |
Accuracy | 98% at 20 mm/h; 96% at 50 mm/h; 95% at 120 mm/h |
Maximum rainfall rate | 2000 mm/h |
Collector area | 127 cm² |
Power Supply and Consumption | |
|---|---|
Power supply | 10…30 Vdc |
Power consumption without heater | 26 mA at 24 Vdc |
Power consumption with heater | 8 W at 24 Vdc |
Analog Outputs | |
|---|---|
Number of analog outputs | 2 |
Output parameters | Wind speed and wind direction |
Standard output | 4…20 mA |
Optional output selections | 0…1 V, 0…5 V or 0…10 V |
Output configuration | Factory-configurable; specified when ordering |
Power supply requirement for 0…10 V output | 15…30 Vdc |
Serial Communication | |
|---|---|
Serial interfaces | RS232, RS485 (¼ Unit Load), RS422 and SDI-12 |
Communication protocols | Proprietary ASCII, NMEA, Modbus-RTU and SDI-12 |
Wind Averaging | |
|---|---|
Wind speed averaging interval | Configurable from 1 s to 10 min |
Environmental | |
|---|---|
Operating temperature | −40…+70 °C |
Minimum temperature for rainfall sensor | 1 °C |
Protection degree | IP66 |
Survival speed | 90 m/s (60 m/s with rain gauge option) |
Mechanical | |
|---|---|
Case | Plastic material |
Metal parts | AISI 316 |
Mounting | Ø 40 mm mast |
Electrical connection | 19-pole M23 male connector |
Weight – HD52.3DP147 | About 1 kg |
Weight – HD52.3DT147 | About 1.5 kg |
Available Options | |
|---|---|
4 | Barometric pressure |
17 | Temperature and relative humidity |
P | Global solar radiation |
T | Rainfall |
K | Bird spikes |
R | Heating |
V | 0…10 V analog output |
V1 | 0…1 V analog output |
V5 | 0…5 V analog output |
Drawing

Downloads
| HD52.3D Family User Manual | DownloadHD52.3D Family User Manual |
|---|---|
| HD52.3D Family CE Declaration of Conformity | DownloadHD52.3D Family CE Declaration of Conformity |
Related Products

Senseca
SEMS-2000 Solar Energy Measurement System
Compact 2-axis solar tracking system for automatic DNI, DHI and GHI monitoring with suitable sensors.
Learn More
Senseca
HDMCS-100 Compact Weather Station
Compact, self-powered automatic weather station for wind, temperature, humidity, pressure and rainfall monitoring.
Learn More
Senseca
GEO-MDFS2 Dust Fall Monitoring System
Dust fall monitoring system for PV panel cleaning decisions.
Learn More
Senseca
VNR 21/22 Conductive Level Signal Amplifier
Signal amplifier for SL series conductive level probes.
Learn More