WETEC
HD52.3D 2-Axis Ultrasonic Anemometer thumbnail 1
HD52.3D 2-Axis Ultrasonic Anemometer thumbnail 2
HD52.3D 2-Axis Ultrasonic Anemometer thumbnail 3
HD52.3D 2-Axis Ultrasonic Anemometer thumbnail 4
HD52.3D 2-Axis Ultrasonic Anemometer thumbnail 5

Senseca

HD52.3D 2-Axis Ultrasonic Anemometer


2-axis ultrasonic anemometer for wind speed, direction, gust and U-V wind components.

  • Wind speed 0…60 m/s (0…50 m/s with rain gauge option) and direction 0…359.9°

  • Built-in magnetic compass for automatic wind direction compensation

  • Two analog outputs and RS232, RS485, RS422 and SDI-12 serial interfaces

  • Optional temperature and relative humidity, barometric pressure, and either global solar radiation or rainfall

  • IP66 protection, optional heating and no moving parts

Quantity
1

Overview

The Senseca HD52.3D series consists of 2-axis ultrasonic anemometers designed to measure wind speed, wind direction, wind gusts and U-V Cartesian wind components without moving parts. Wind speed is measured over a range of 0…60 m/s (0…50 m/s with the rain gauge option), while wind direction covers 0…359.9°. A built-in magnetic compass automatically compensates wind measurements and references them to magnetic North, even when the instrument is not aligned to North.

The instruments provide two analog outputs for wind speed and direction, factory-configurable as 4…20 mA (standard), 0…1 V, 0…5 V or 0…10 V. RS232, RS485, RS422 and SDI-12 serial interfaces are available, supporting proprietary ASCII, NMEA, Modbus-RTU and SDI-12 communication protocols. Wind speed and direction averaging intervals are configurable from 1 second to 10 minutes.

Optional measurement features include air temperature and relative humidity, barometric pressure, and either global solar radiation or rainfall, which are mutually exclusive options. The instruments feature IP66 protection, operate on a 10…30 Vdc power supply and support mounting on a Ø 40 mm mast. An optional heater, unavailable on the rain gauge model, prevents snow and ice accumulation on the ultrasonic transducers. The absence of moving parts minimises maintenance requirements.

Typical Applications

  • Wind speed, direction and gust monitoring in meteorological stations

  • Wind measurement in fixed and mobile installations

  • Multi-parameter meteorological monitoring with optional environmental sensors

  • Remote weather monitoring using photovoltaic panels and backup batteries

  • Wind data integration with data loggers, PLCs and monitoring networks

  • Wind measurement in snowy and icy conditions with optional transducer heating

Key Features

  • 2-axis ultrasonic wind measurement without moving parts

  • Wind speed range 0…60 m/s (0…50 m/s with rain gauge option)

  • Wind direction range 0…359.9° with 0.1° resolution

  • Wind gust and U-V Cartesian wind component measurements

  • Built-in magnetic compass for automatic wind direction compensation

  • Two analog outputs, factory-configurable as 4…20 mA, 0…1 V, 0…5 V or 0…10 V

  • RS232, RS485, RS422 and SDI-12 serial interfaces

  • Proprietary ASCII, NMEA, Modbus-RTU and SDI-12 communication protocols

  • Configurable wind averaging interval from 1 s to 10 min

  • Optional temperature and relative humidity, barometric pressure, and either global solar radiation or rainfall measurement

  • Optional ultrasonic transducer heating to prevent snow and ice accumulation (not available with rain gauge option)

  • IP66 protection with plastic housing and AISI 316 metal parts

  • 10…30 Vdc power supply (15…30 Vdc required for 0…10 V analog output)

  • Mounting on Ø 40 mm mast with M23 19-pole electrical connector

  • Factory-calibrated sensors requiring no field calibration

Benefits

  • Reduced maintenance requirements with no moving parts

  • Wind measurements automatically compensated and referenced to magnetic North

  • Wind speed, direction, gust and U-V components measured by one instrument

  • Flexible integration with data loggers, PLCs and monitoring systems

  • Expanded meteorological monitoring with optional environmental sensors

  • Suitable for remote installations with low power consumption

  • Factory-calibrated sensors requiring no field calibration

  • Optional heating prevents snow and ice accumulation on ultrasonic transducers (not available with rain gauge option)

Specifications

Wind Speed

Sensor

Ultrasounds

Measuring range

0…60 m/s (0…50 m/s with rain gauge option)

Resolution

0.01 m/s

Accuracy

±0.2 m/s or ±2%, whichever is greater (0…35 m/s); ±3% (above 35 m/s)

 

 

Wind Direction

Sensor

Ultrasounds

Measuring range

0…359.9°

Resolution

0.1°

Accuracy

±2° RMSE from 1.0 m/s

 

 

Magnetic Compass

Sensor

Magnetic

Measuring range

0…360°

Resolution

0.1°

Accuracy

±1°

 

 

Air Temperature (Optional – Option 17)

Sensor

Pt100

Measuring range

−40…+70 °C

Resolution

0.1 °C

Accuracy

±0.15 °C ±0.1% of measurement

 

 

Relative Humidity (Optional – Option 17)

Sensor

Capacitive

Measuring range

0…100% RH

Resolution

0.1% RH

Accuracy at 15…35 °C

±1.5% RH (0…90% RH); ±2% RH (remaining range)

Accuracy at −40…+70 °C

±(1.5 + 1.5% of measurement)% RH

 

 

Barometric Pressure (Optional – Option 4)

Sensor

Piezoresistive

Measuring range

300…1100 hPa

Resolution

0.1 hPa

Accuracy at 20 °C

±0.5 hPa (700…1100 hPa)

Accuracy at 0…60 °C

±1 hPa (500…1100 hPa); ±1.5 hPa (300…500 hPa)

Long-term stability

±1 hPa/year

 

 

Global Solar Radiation (Optional – Option P)

Sensor

Thermopile

Measuring range

0…2000 W/m²

Resolution

1 W/m²

Classification

Spectrally Flat Class C

 

 

Rainfall (Optional – Option T)

Sensor

Tipping bucket

Resolution

0.2 mm

Accuracy

98% at 20 mm/h; 96% at 50 mm/h; 95% at 120 mm/h

Maximum rainfall rate

2000 mm/h

Collector area

127 cm²

 

 

Power Supply and Consumption

Power supply

10…30 Vdc

Power consumption without heater

26 mA at 24 Vdc

Power consumption with heater

8 W at 24 Vdc

 

 

Analog Outputs

Number of analog outputs

2

Output parameters

Wind speed and wind direction

Standard output

4…20 mA

Optional output selections

0…1 V, 0…5 V or 0…10 V

Output configuration

Factory-configurable; specified when ordering

Power supply requirement for 0…10 V output

15…30 Vdc

 

 

Serial Communication

Serial interfaces

RS232, RS485 (¼ Unit Load), RS422 and SDI-12

Communication protocols

Proprietary ASCII, NMEA, Modbus-RTU and SDI-12

 

 

Wind Averaging

Wind speed averaging interval

Configurable from 1 s to 10 min

 

 

Environmental

Operating temperature

−40…+70 °C

Minimum temperature for rainfall sensor

1 °C

Protection degree

IP66

Survival speed

90 m/s (60 m/s with rain gauge option)

 

 

Mechanical

Case

Plastic material

Metal parts

AISI 316

Mounting

Ø 40 mm mast

Electrical connection

19-pole M23 male connector

Weight – HD52.3DP147

About 1 kg

Weight – HD52.3DT147

About 1.5 kg

 

 

Available Options

4

Barometric pressure

17

Temperature and relative humidity

P

Global solar radiation

T

Rainfall

K

Bird spikes

R

Heating

V

0…10 V analog output

V1

0…1 V analog output

V5

0…5 V analog output

Drawing

HD52.3D 2-Axis Ultrasonic Anemometer Drawing

Downloads

HD52.3D Family User Manual DownloadHD52.3D Family User Manual
HD52.3D Family CE Declaration of Conformity DownloadHD52.3D Family CE Declaration of Conformity