  • Magnetic reed contacts inside the measuring rod are driven by one or more floats, and the float is the only moving element.

  • Up to 6 switch points and rod lengths up to 6 m, with working pressure up to 50 bar depending on the float used.

  • Ambient temperature -30/+55 °C, standard working temperature 105 °C (versions up to 180 °C on request) and minimum IP65 protection.

Quantity
1

Overview

The Senseca MULTIPOINT S is a stainless steel (AISI 316) level switch for liquid level control, with up to 6 switch points and rod lengths up to 6 m. One or more magnetic reed contacts placed inside the measuring rod are driven by one or more floats.

The float is the only moving element and moves along the rod by buoyancy, which gives extreme robustness and a limited need for maintenance. Working pressure goes up to 50 bar depending on the float, and the minimum degree of protection is IP65.

Typical applications

  • Liquid level control

  • Multi-point liquid level monitoring

  • Level monitoring in tanks (vertical mounting)

Key Features

  • Stainless steel AISI 316 construction

  • Up to 6 switch points and up to 6 m length

  • Working pressure up to 50 bar depending on the float used

  • Operating ambient temperature -30/+55 °C, UR 90 %

  • Standard working temperature 105 °C, versions up to 180 °C on request

  • Minimum degree of protection IP65

  • Five float types: S29, S32, S41, S52 and S100

  • Threaded or flanged process connections

  • Electrical output via IP65 housing, DIN 43650 plug, cable, leads or cable gland

  • Built-in temperature sensor on request (PT100/PT1000, PTC, NTC or thermostat)

Benefits

  • Extreme robustness, as the float is the only moving element

  • Limited need for maintenance

  • Choice of float, process connection and electrical output to fit the installation

  • SPST (NO or NC) or SPDT contacts, with independent, common or customer-specified wiring

  • Reed contacts rated up to 100,000,000 operations

  • ATEX versions are available in the separate Multipoint E and Multipoint I series

Specifications

GENERAL

 

Operating principle

One or more magnetic reed contacts inside the measuring rod, driven by one or more floats

Number of switch points

Up to 6

Length

Up to 6 m

Tolerance on switch points

± 3 mm

Max. fluid viscosity

150 cSt

Installation

Vertical position ±15°

 

 

FLOATS

 

Float material

Stainless steel AISI 316

Float S29 (∅30x32)

Specific gravity 0.75; contact type 3 (max. 6 contacts) or 7D (max. 4 contacts); max. 30 bar

Float S32 (∅30x32)

Specific gravity 0.55; contact type 3 (max. 6 contacts) or 7D (max. 4 contacts); max. 10 bar

Float S41 (∅41x35)

Specific gravity 0.65; contact type 4 or 7 (max. 6 contacts); max. 10 bar

Float S52 (∅52)

Specific gravity 0.7; contact type 4 or 7 (max. 6 contacts); max. 50 bar

Float S100 (∅100)

Specific gravity 0.6; contact type 7 (max. 6 contacts); max. 15 bar

 

 

OUTPUTS

 

Contact type 3 (SPST)

70 VA / 50 W; 300 V AC / 300 V DC; 0.5 A AC / 0.7 A DC

Contact type 4 (SPST)

80 VA / 80 W; 250 V AC / 250 V DC; 1.3 A AC / 1.3 A DC

Contact type 7 (SPDT)

60 VA / 60 W; 230 V AC / 230 V DC; 1 A AC / 1 A DC

Contact type 7D (SPDT)

20 VA / 20 W; 150 V AC / 150 V DC; 0.5 A AC / 0.5 A DC

Wiring

I: independent (separately wired contacts); C: common (common wired contacts); S: custom (wired on customer request)

Contact status in no level condition

1: NO; 2: NC; 3: SPDT

Electrical output W1 / W2

IP65 housing; W1: max. 5 terminals; W2: max. 18 terminals

Electrical output S1 / S2

DIN IP65 plug; S1: DIN 43650 29x29; S2: DIN 43650 15x15

Electrical output C1 / C2 / T1

C1: cable L = 1.5 m; C2: cable L = 3.0 m; T1: leads L = 1.5 m

Electrical output P1 / P2

Cable gland; P1: brass IP68; P2: polyamide IP67

 

 

ENVIRONMENTAL

 

Operating ambient temperature

-30/+55 °C, UR 90 %

Standard working temperature

105 °C (class L)

Working temperature on request

N: 130 °C (S1 and S2 outputs); R: 150 °C; H: 180 °C

Working pressure

Up to 50 bar, depending on the float used

Degree of protection

Minimum IP65

 

 

MATERIALS

 

Construction

Stainless steel AISI 316

Rod and process connection material

AISI 316 (AISI 304 on request)

DN flange material

Steel or AISI 316

 

 

MECHANICAL

 

Process connection, installation from inside (outputs C, P, T)

1/8", 1/4", 3/8", 1/2"; all float types, all thread types

Process connection, installation from outside

Floats S29 / S32: 1" (G), 1¼" (G, C, N); S41: 1½", 2" (G, C, N); S52: 2" (G, C, N)

Thread types

G: parallel UNI 228/1; C: conical UNI 7/1; N: conical NPT

Flanges

Floats S29 / S32: FSHX, FSPX or DN flanges; floats S41 / S52 / S100: DN flanges (UNI, DIN, ANSI)

Flange FSPX

∅55 mm; 2 holes on ∅43 mm or 3 holes on ∅42 mm; hole ∅4.5 mm

Flange FSHX

∅70 mm; 6 holes on ∅60 mm; hole ∅4.5 mm; thickness 4 mm

Min. distance A (flanged connection)

S29: 20 mm; S32: 20 mm; S41: 30 mm; S52: 35 mm; S100: 60 mm

Min. distance A1 (threaded connection)

S29: 40 mm; S32: 40 mm; S41: 50 mm; S52: 55 mm

Min. distance B

S29: 25 mm; S32: 25 mm; S41: 35 mm; S52: 40 mm; S100: 70 mm

Min. distance C

S29: 45 mm; S32: 45 mm; S41: 65 mm; S52: 75 mm; S100: 125 mm

 

 

OPTIONS

 

Built-in temperature sensor (bottom of the rod)

On request. PT100 / PT1000 (EN 60751 / IEC 751, class B, class A on request); PTC (resistance at 25 °C ≤ 500 Ω, temperature 60…120 °C); NTC (resistance at 25 °C 2-5-10-50-100 kΩ, precision ±5 % / ±3 % on request); TRM thermostat (40…120 °C in 10 °C steps, precision ±5 %, differential 10 °C ±4 °C)

 

 