Senseca
MULTIPOINT S Multi-Point Level Switch
Multi-point float level switch in AISI 316 for liquid monitoring
Magnetic reed contacts inside the measuring rod are driven by one or more floats, and the float is the only moving element.
Up to 6 switch points and rod lengths up to 6 m, with working pressure up to 50 bar depending on the float used.
Ambient temperature -30/+55 °C, standard working temperature 105 °C (versions up to 180 °C on request) and minimum IP65 protection.
Overview
The Senseca MULTIPOINT S is a stainless steel (AISI 316) level switch for liquid level control, with up to 6 switch points and rod lengths up to 6 m. One or more magnetic reed contacts placed inside the measuring rod are driven by one or more floats.
The float is the only moving element and moves along the rod by buoyancy, which gives extreme robustness and a limited need for maintenance. Working pressure goes up to 50 bar depending on the float, and the minimum degree of protection is IP65.
Typical applications
Liquid level control
Multi-point liquid level monitoring
Level monitoring in tanks (vertical mounting)
Key Features
Stainless steel AISI 316 construction
Up to 6 switch points and up to 6 m length
Working pressure up to 50 bar depending on the float used
Operating ambient temperature -30/+55 °C, UR 90 %
Standard working temperature 105 °C, versions up to 180 °C on request
Minimum degree of protection IP65
Five float types: S29, S32, S41, S52 and S100
Threaded or flanged process connections
Electrical output via IP65 housing, DIN 43650 plug, cable, leads or cable gland
Built-in temperature sensor on request (PT100/PT1000, PTC, NTC or thermostat)
Benefits
Extreme robustness, as the float is the only moving element
Limited need for maintenance
Choice of float, process connection and electrical output to fit the installation
SPST (NO or NC) or SPDT contacts, with independent, common or customer-specified wiring
Reed contacts rated up to 100,000,000 operations
ATEX versions are available in the separate Multipoint E and Multipoint I series
Specifications
GENERAL |
|
Operating principle | One or more magnetic reed contacts inside the measuring rod, driven by one or more floats |
Number of switch points | Up to 6 |
Length | Up to 6 m |
Tolerance on switch points | ± 3 mm |
Max. fluid viscosity | 150 cSt |
Installation | Vertical position ±15° |
FLOATS |
|
Float material | Stainless steel AISI 316 |
Float S29 (∅30x32) | Specific gravity 0.75; contact type 3 (max. 6 contacts) or 7D (max. 4 contacts); max. 30 bar |
Float S32 (∅30x32) | Specific gravity 0.55; contact type 3 (max. 6 contacts) or 7D (max. 4 contacts); max. 10 bar |
Float S41 (∅41x35) | Specific gravity 0.65; contact type 4 or 7 (max. 6 contacts); max. 10 bar |
Float S52 (∅52) | Specific gravity 0.7; contact type 4 or 7 (max. 6 contacts); max. 50 bar |
Float S100 (∅100) | Specific gravity 0.6; contact type 7 (max. 6 contacts); max. 15 bar |
OUTPUTS |
|
Contact type 3 (SPST) | 70 VA / 50 W; 300 V AC / 300 V DC; 0.5 A AC / 0.7 A DC |
Contact type 4 (SPST) | 80 VA / 80 W; 250 V AC / 250 V DC; 1.3 A AC / 1.3 A DC |
Contact type 7 (SPDT) | 60 VA / 60 W; 230 V AC / 230 V DC; 1 A AC / 1 A DC |
Contact type 7D (SPDT) | 20 VA / 20 W; 150 V AC / 150 V DC; 0.5 A AC / 0.5 A DC |
Wiring | I: independent (separately wired contacts); C: common (common wired contacts); S: custom (wired on customer request) |
Contact status in no level condition | 1: NO; 2: NC; 3: SPDT |
Electrical output W1 / W2 | IP65 housing; W1: max. 5 terminals; W2: max. 18 terminals |
Electrical output S1 / S2 | DIN IP65 plug; S1: DIN 43650 29x29; S2: DIN 43650 15x15 |
Electrical output C1 / C2 / T1 | C1: cable L = 1.5 m; C2: cable L = 3.0 m; T1: leads L = 1.5 m |
Electrical output P1 / P2 | Cable gland; P1: brass IP68; P2: polyamide IP67 |
ENVIRONMENTAL |
|
Operating ambient temperature | -30/+55 °C, UR 90 % |
Standard working temperature | 105 °C (class L) |
Working temperature on request | N: 130 °C (S1 and S2 outputs); R: 150 °C; H: 180 °C |
Working pressure | Up to 50 bar, depending on the float used |
Degree of protection | Minimum IP65 |
MATERIALS |
|
Construction | Stainless steel AISI 316 |
Rod and process connection material | AISI 316 (AISI 304 on request) |
DN flange material | Steel or AISI 316 |
MECHANICAL |
|
Process connection, installation from inside (outputs C, P, T) | 1/8", 1/4", 3/8", 1/2"; all float types, all thread types |
Process connection, installation from outside | Floats S29 / S32: 1" (G), 1¼" (G, C, N); S41: 1½", 2" (G, C, N); S52: 2" (G, C, N) |
Thread types | G: parallel UNI 228/1; C: conical UNI 7/1; N: conical NPT |
Flanges | Floats S29 / S32: FSHX, FSPX or DN flanges; floats S41 / S52 / S100: DN flanges (UNI, DIN, ANSI) |
Flange FSPX | ∅55 mm; 2 holes on ∅43 mm or 3 holes on ∅42 mm; hole ∅4.5 mm |
Flange FSHX | ∅70 mm; 6 holes on ∅60 mm; hole ∅4.5 mm; thickness 4 mm |
Min. distance A (flanged connection) | S29: 20 mm; S32: 20 mm; S41: 30 mm; S52: 35 mm; S100: 60 mm |
Min. distance A1 (threaded connection) | S29: 40 mm; S32: 40 mm; S41: 50 mm; S52: 55 mm |
Min. distance B | S29: 25 mm; S32: 25 mm; S41: 35 mm; S52: 40 mm; S100: 70 mm |
Min. distance C | S29: 45 mm; S32: 45 mm; S41: 65 mm; S52: 75 mm; S100: 125 mm |
OPTIONS |
|
Built-in temperature sensor (bottom of the rod) | On request. PT100 / PT1000 (EN 60751 / IEC 751, class B, class A on request); PTC (resistance at 25 °C ≤ 500 Ω, temperature 60…120 °C); NTC (resistance at 25 °C 2-5-10-50-100 kΩ, precision ±5 % / ±3 % on request); TRM thermostat (40…120 °C in 10 °C steps, precision ±5 %, differential 10 °C ±4 °C) |
APPROVALS |
|
Conformity | CE |
Downloads
| Senseca-MULTIPOINT-S-Datasheet-EN | DownloadSenseca-MULTIPOINT-S-Datasheet-EN |
|---|---|
| Senseca-Level-Switch-User-Manual-EN-IT | DownloadSenseca-Level-Switch-User-Manual-EN-IT |
Related Products

Senseca
NW1 Float Level Switch for Side Installation
Float level switch for fluid media monitoring with reed switch, G ¾ A or G 1 A thread, normally open or normally closed contact, max.
Learn More
Senseca
SCM-300 Vibrating Fork Level Switch
Vibrating fork level switch for liquid limit detection in tanks, vessels and pipes, with DC-PNP or AC/DC output, pressure up to 40 bar and a WHG version…
Learn More
Senseca
USP4 Ultrasonic Level Transmitter
Ultrasonic level transmitter for non-contact level, volume and open-channel flow measurement in liquids, pastes and coarse bulk solids, with ranges up to 8 m.
Learn More
Senseca
USN Ultrasonic Level Transmitter
Non-contact ultrasonic level transmitter and switch for liquids, pastes and coarse bulk materials.
Learn More