WETEC
USN Ultrasonic Level Transmitter thumbnail 1
USN Ultrasonic Level Transmitter thumbnail 2
USN Ultrasonic Level Transmitter thumbnail 3

Senseca

USN Ultrasonic Level Transmitter


Ultrasonic level transmitter and level switch for non-contact measurement.

  • Liquids, pastes and coarse bulk materials, ranges up to 8 m

  • 0/4…20 mA or 0…10 V output and up to 4 PNP switch outputs

  • Graphic display, optional Bluetooth and data logger

Quantity
1

Overview

The Sonicont USN is an ultrasonic level transmitter and level switch for monitoring, control and continuous non-contact measurement of filling levels in liquids, pastes and coarse bulk materials. It can also be used for volume measurement and for flow measurement at open channels and measuring weirs. Three versions cover measuring ranges up to 2 m, 5 m and 8 m, with a characteristic deviation of ≤ ±2 mm or ±0.2% of the set measuring range.

The integrated electronics provide a 0/4…20 mA or 0…10 V output and up to four PNP switch outputs. A high-contrast graphic TFT-LCD display and 3-key operation allow setup without extra tools, and the enclosure and display can be rotated to suit the installation. Options include a Bluetooth interface and a data logger with time stamp for more than 500,000 measuring values. The device is rated IP65/IP67, with a process temperature range of -40…+85 °C.

Typical applications

  • Non-contact level and volume measurement

  • Flow measurement at open channels and measuring weirs

  • Water and waste water sector

  • Process industry

  • Environmental technology

  • Storage tanks, storage bunkers and silos

Key Features

  • Non-contact ultrasonic measurement of liquids, pastes and coarse bulk materials

  • Measuring ranges up to 2 m, 5 m or 8 m

  • Characteristic deviation ≤ ±2 mm or ±0.2% of set range

  • 0/4…20 mA or 0…10 V output

  • Up to 4 PNP switch outputs

  • Graphic TFT-LCD display with 3-key operation

  • Optional Bluetooth interface

  • Optional data logger for ≥ 500,000 values, with time stamp

  • Process temperature -40…+85 °C, IP65/IP67

  • M12 plug connection

Benefits

  • No contact with the medium

  • Level transmitter and level switch in one device

  • Enclosure and display rotate for easy reading in any installation position

  • Easy setup with clear menu navigation and tactile keys

  • Extensive diagnostic functions for system analysis

  • Laser-marked type label for identification throughout the device's lifetime

Specifications

INPUT

 

Measuring principle

Ultrasonic, non-contact (piezo sensor, PVDF)

Measuring ranges

≤ 2 m / ≤ 5 m / ≤ 8 m

Blocking distance

≤ 0.15 m (2 m) / ≤ 0.20 m (5 m) / ≤ 0.30 m (8 m)

Operating frequency

125 kHz (2 m) / 75 kHz (5 m) / 50 kHz (8 m)

Emitting angle (-3 dB)

10° ±2° (2 m) / 14° ±2° (5 m) / 10° ±2° (8 m)

Pulse rate

5 / 2.5 / 1.25 Hz (2 m); 2.5 / 1.25 / 0.625 Hz (5 m); 2 / 1 / 0.5 Hz (8 m)

 

 

MEASURING ACCURACY

 

Characteristic deviation

≤ ±2 mm or ±0.2% of set measuring range, whichever is greater

Long-term drift

≤ ±0.1% FS/year, not cumulative

Temperature deviation

≤ ±0.006% FS/K

 

 

OUTPUTS

 

Analog output

0…20 mA (0…20.5 mA, max. 22 mA), 4…20 mA (3.8…20.5 mA, min. 3.6 mA, max. 22 mA) or 0…10 V (0…10.5 V, max. 11 V)

Permitted load

Current: RL ≤ (Us - 9 V) / 22 mA; voltage: RL ≥ UOut / 3 mA

Switch outputs

None, 2x or 4x PNP (S1…S4), switching to +L; 0…≤ 200 mA, current limited, short-circuit protected; ≥ 100,000,000 switch cycles

Start-up time

≤ 1 s

 

 

DISPLAY & INTERFACES

 

Display

Graphic TFT-LCD display, 3-key operation; enclosure and display rotatable

Bluetooth (optional)

Bluetooth 2.1 + EDR, Class 2, range ≤ 10 m

Data logger (optional)

≥ 500,000 measuring values, ring memory, memory rate 1…99999 s, with time stamp

 

 

POWER REQUIREMENT

 

Supply voltage

9…30 Vdc (0/4…20 mA output) / 14…30 Vdc (0…10 V output), reverse polarity protected

Supply current

≤ 50…130 mA, depending on supply voltage, output and Bluetooth on/off

 

 

ENVIRONMENTAL

 

Process temperature

-40…+85 °C

Process pressure

-0.3…2 bar

Ambient temperature

-20…+70 °C (-20…+60 °C at backlight ≥ 60%, -20…+50 °C at backlight ≥ 80%)

Protection degree

IP65/IP67 (EN/IEC 60529)

Climate class

4K4H (EN/IEC 60721-3-4)

Shock / vibration

15 g [11 ms] (EN/IEC 60068-2-27) / 4 g [10…2000 Hz] (EN/IEC 60068-2-6)

EMC

Class B / industrial range (EN/IEC 61326)

 

 

MATERIALS

 

Sensor

PVDF

Process connection

Steel 1.4404/316L / 1.4571/316Ti; process gasket EPDM

Terminal enclosure

CrNi-steel

Control panel surface

PES

Device plug

PUR

Gaskets

FPM (e.g. Viton®)

 

 

MECHANICAL

 

Process connection

G1"B (2 m), G1½"B (5 m) or G2"B (8 m), ISO 228-1

Electrical connection

M12x1 plug, A-coded

Weight

0.6 kg (2 m) / 1.0 kg (5 m) / 1.2 kg (8 m)

Drawing

USN-Dimensional-Drawing

Downloads

Sonicont-USN-Datasheet-EN DownloadSonicont-USN-Datasheet-EN
Sonicont-USN-User-Manual-EN DownloadSonicont-USN-User-Manual-EN