Senseca
OMNIPLUS-RRI-025 Impeller Flow Transmitter DN 25
Impeller flow transmitter for water and low-viscosity liquids
Impeller with metal clips detected by an inductive sensor outside the flow chamber, with a measurement uncertainty of ±3 % of reading.
Measures 2...100 l/min in DN 25 and PN 16, with media temperature 0...+60 °C and no inlet and outlet sections required.
LCD, IO-Link, analog output and 2 configurable switching outputs, with connections (female thread, male thread or hose nozzle) that can be plugged in and rotated.
Overview
The Senseca OMNIPLUS-RRI-025 is a flow transmitter for water and other low-viscosity liquids in DN 25 and PN 16. An impeller is set in rotation by the flowing medium, and its speed depends linearly on the flow rate.
The impeller has metal clips that are detected by an inductive sensor outside the flow chamber. The integrated electronics have an LCD display, an analog output, two switching outputs and an IO-Link interface, and are easily configured by the user.
Typical applications
Flow measurement of water
Flow measurement of other low-viscosity liquids
Flow monitoring with limit switch, frequency or pulse outputs
Volume metering with preset counter
Applications needing visual inspection of the impeller (version with transparent cover)
Applications with special chemical resistance requirements (PVDF housing option)
Key Features
Long life due to high-quality ceramic axle and special plastic bearings
No inlet and outlet sections required
Modular design with different connection systems
Connections can be plugged in and rotated
Measuring range 2...100 l/min in DN 25 (depending on inlet drilling)
Measurement uncertainty ±3 % of reading
Pressure loss max. 0.5 bar, compressive strength PN 16
1.2" graphic LCD, analog output and 2 configurable switching outputs
IO-Link interface
Benefits
Long service life thanks to the shatterproof ceramic axle and durable plastic bearings
Easy installation, no inlet and outlet sections required
Connections can be plugged in and rotated
Housing in PPS, with PVDF available for special chemical resistance requirements
Transparent PSU cover option for visual inspection of the impeller
Easy configuration by the user, plus digital communication through IO-Link
Specifications
INPUT |
|
Measuring principle | Impeller with metal clips; detection with inductive sensor |
Nominal size | DN 25 |
Media | Water or other low-viscous liquids |
Measuring range, inlet drilling Ø 8.0 mm (code 080) | 2.0...30.0 l/min (H2O); Qmax 36.0 l/min (H2O) |
Measuring range, inlet drilling Ø 12.0 mm (code 120) | 3.0...60.0 l/min (H2O); Qmax 72.0 l/min (H2O) |
Measuring range, inlet drilling Ø 16.0 mm (code 160) | 4.0...100.0 l/min (H2O); Qmax 120.0 l/min (H2O) |
MEASURING ACCURACY |
|
Measurement uncertainty | ±3 % of reading |
OUTPUTS |
|
Analog output, current | 4...20 mA; 0...20 mA |
Analog output, voltage | 0...10 V; 2...10 V; 0...5 V; 1...5 V; 0.5...4.5 V |
Switching outputs | 2 transistor outputs push-pull, parameterizable as NPN o.C.; short-circuit and reverse polarity resistant; Iout = 100 mA max per output |
Switching output functions | Configurable on the device as limit switch, frequency output, pulse output or signal output for preset counter |
IO-LINK |
|
IO-Link revision | V1.1 |
Bit rate | COM2 (38400 bit/s) |
Minimum cycle time | 20 ms |
SIO mode | Yes |
Port class | A compatible |
Block parameterization | Yes |
Data storage | Yes |
DISPLAY |
|
Display | Graphic 1.2" LCD (transflective), 128 x 64 pixels |
Backlight | White, red on alarm message |
POWER REQUIREMENT |
|
Supply voltage | 18...30 V DC |
Current consumption | < 130 mA (SIO mode, unloaded outputs) |
ENVIRONMENTAL |
|
Media temperature | 0...+60 °C |
Compressive strength | PN 16 |
Pressure loss | Max. 0.5 bar |
Storage temperature | -20...+80 °C |
Protection class | IP65 / IP67 |
MATERIALS |
|
Housing | PPS (40 % GF); optional PVDF; optional PPS with transparent cover PSU |
Impeller | PVDF |
Clips | 1.4310 (optional: titanium) |
Bearings | Iglidur X |
Axle | Ceramics ZrO2-TZP |
Gaskets | FKM; optional NBR, EPDM |
Connection material | PVDF; optional CW614N nickel-plated or 1.4305 |
MECHANICAL |
|
Connection type | Female thread G 1 (standard); male thread G 1 A (option); hose nozzle Ø30 (option) |
Other connections | Other threads, crimp and plug-in connections, connections with constants or limiters on request |
Electrical connection | M12x1 circular connector, 5-pin |
Pin assignment | 1 BN: L+; 2 WH: Analog; 3 BU: L-; 4 BK: IO-Link/DO; 5 GY: DI/DO |
Weight | Approx. 0.51 kg |
APPROVALS |
|
Conformity | CE |
Downloads
| Senseca-OMNIPLUS-RRI-Datasheet-EN | DownloadSenseca-OMNIPLUS-RRI-Datasheet-EN |
|---|
Related Products

Senseca
OMNIPLUS-F Thermal Flow and Temperature Transmitter
Thermal flow and temperature transmitter for water and other liquids, measuring flow from 2.300 cm/s with a 1.2 inch graphic LCD, IO-Link, analog output and…
Learn More
Senseca
SIMPLE R1 Adjustable Float Level Switch
Adjustable level switch for liquid monitoring in industrial and civil environments, with SPST or SPDT sealed contact, 500 or 1000 mm rod length, DIN 43650…
Learn More
Senseca
MULTIPOINT S Multi-Point Level Switch
Stainless steel (AISI 316) float level switch for liquid level control with up to 6 switch points, rod lengths up to 6 m, working pressure up to 50 bar and…
Learn More
Senseca
NW1 Float Level Switch for Side Installation
Float level switch for fluid media monitoring with reed switch, G ¾ A or G 1 A thread, normally open or normally closed contact, max.
Learn More