WETEC
OMNIPLUS-RRI-025 Impeller Flow Transmitter DN 25 thumbnail 1
OMNIPLUS-RRI-025 Impeller Flow Transmitter DN 25 thumbnail 2
OMNIPLUS-RRI-025 Impeller Flow Transmitter DN 25 thumbnail 3
OMNIPLUS-RRI-025 Impeller Flow Transmitter DN 25 thumbnail 4

Senseca

OMNIPLUS-RRI-025 Impeller Flow Transmitter DN 25


Impeller flow transmitter for water and low-viscosity liquids

  • Impeller with metal clips detected by an inductive sensor outside the flow chamber, with a measurement uncertainty of ±3 % of reading.

  • Measures 2...100 l/min in DN 25 and PN 16, with media temperature 0...+60 °C and no inlet and outlet sections required.

  • LCD, IO-Link, analog output and 2 configurable switching outputs, with connections (female thread, male thread or hose nozzle) that can be plugged in and rotated.

Quantity
1

Overview

The Senseca OMNIPLUS-RRI-025 is a flow transmitter for water and other low-viscosity liquids in DN 25 and PN 16. An impeller is set in rotation by the flowing medium, and its speed depends linearly on the flow rate.

The impeller has metal clips that are detected by an inductive sensor outside the flow chamber. The integrated electronics have an LCD display, an analog output, two switching outputs and an IO-Link interface, and are easily configured by the user.

Typical applications

  • Flow measurement of water

  • Flow measurement of other low-viscosity liquids

  • Flow monitoring with limit switch, frequency or pulse outputs

  • Volume metering with preset counter

  • Applications needing visual inspection of the impeller (version with transparent cover)

  • Applications with special chemical resistance requirements (PVDF housing option)

Key Features

  • Long life due to high-quality ceramic axle and special plastic bearings

  • No inlet and outlet sections required

  • Modular design with different connection systems

  • Connections can be plugged in and rotated

  • Measuring range 2...100 l/min in DN 25 (depending on inlet drilling)

  • Measurement uncertainty ±3 % of reading

  • Pressure loss max. 0.5 bar, compressive strength PN 16

  • 1.2" graphic LCD, analog output and 2 configurable switching outputs

  • IO-Link interface

Benefits

  • Long service life thanks to the shatterproof ceramic axle and durable plastic bearings

  • Easy installation, no inlet and outlet sections required

  • Connections can be plugged in and rotated

  • Housing in PPS, with PVDF available for special chemical resistance requirements

  • Transparent PSU cover option for visual inspection of the impeller

  • Easy configuration by the user, plus digital communication through IO-Link

Specifications

INPUT

 

Measuring principle

Impeller with metal clips; detection with inductive sensor

Nominal size

DN 25

Media

Water or other low-viscous liquids

Measuring range, inlet drilling Ø 8.0 mm (code 080)

2.0...30.0 l/min (H2O); Qmax 36.0 l/min (H2O)

Measuring range, inlet drilling Ø 12.0 mm (code 120)

3.0...60.0 l/min (H2O); Qmax 72.0 l/min (H2O)

Measuring range, inlet drilling Ø 16.0 mm (code 160)

4.0...100.0 l/min (H2O); Qmax 120.0 l/min (H2O)

 

 

MEASURING ACCURACY

 

Measurement uncertainty

±3 % of reading

 

 

OUTPUTS

 

Analog output, current

4...20 mA; 0...20 mA

Analog output, voltage

0...10 V; 2...10 V; 0...5 V; 1...5 V; 0.5...4.5 V

Switching outputs

2 transistor outputs push-pull, parameterizable as NPN o.C.; short-circuit and reverse polarity resistant; Iout = 100 mA max per output

Switching output functions

Configurable on the device as limit switch, frequency output, pulse output or signal output for preset counter

 

 

IO-LINK

 

IO-Link revision

V1.1

Bit rate

COM2 (38400 bit/s)

Minimum cycle time

20 ms

SIO mode

Yes

Port class

A compatible

Block parameterization

Yes

Data storage

Yes

 

 

DISPLAY

 

Display

Graphic 1.2" LCD (transflective), 128 x 64 pixels

Backlight

White, red on alarm message

 

 

POWER REQUIREMENT

 

Supply voltage

18...30 V DC

Current consumption

< 130 mA (SIO mode, unloaded outputs)

 

 

ENVIRONMENTAL

 

Media temperature

0...+60 °C

Compressive strength

PN 16

Pressure loss

Max. 0.5 bar

Storage temperature

-20...+80 °C

Protection class

IP65 / IP67

 

 

MATERIALS

 

Housing

PPS (40 % GF); optional PVDF; optional PPS with transparent cover PSU

Impeller

PVDF

Clips

1.4310 (optional: titanium)

Bearings

Iglidur X

Axle

Ceramics ZrO2-TZP

Gaskets

FKM; optional NBR, EPDM

Connection material

PVDF; optional CW614N nickel-plated or 1.4305

 

 

MECHANICAL

 

Connection type

Female thread G 1 (standard); male thread G 1 A (option); hose nozzle Ø30 (option)

Other connections

Other threads, crimp and plug-in connections, connections with constants or limiters on request

Electrical connection

M12x1 circular connector, 5-pin

Pin assignment

1 BN: L+; 2 WH: Analog; 3 BU: L-; 4 BK: IO-Link/DO; 5 GY: DI/DO

Weight

Approx. 0.51 kg

 

 

APPROVALS

 

Conformity

CE

Downloads

Senseca-OMNIPLUS-RRI-Datasheet-EN DownloadSenseca-OMNIPLUS-RRI-Datasheet-EN