WETEC
RWS-30 Visibility Sensor thumbnail 1
RWS-30 Visibility Sensor thumbnail 2
RWS-30 Visibility Sensor thumbnail 3

Senseca

RWS-30 Visibility Sensor


Forward scatter visibility sensor for road and tunnel safety monitoring.

  • Measures MOR from 200 m to 99.99 km and EXCO from 0.03 to 15 km⁻¹

  • RS232, RS422 or RS485 serial communication with 0…10 V and selectable 0…20 mA or 4…20 mA analog outputs

  • Automatic window contamination correction with two-stage cleaning warnings

  • IP66/IP67 powder-coated aluminium housing, operating temperature −40…+60 °C

Quantity
1

Overview

The Senseca RWS-30 is a forward scatter visibility sensor designed for road and tunnel safety monitoring. It measures Meteorological Optical Range (MOR) from 200 m to 99.99 km and atmospheric extinction coefficient (EXCO) from 0.03 to 15 km⁻¹, supporting fog detection, pollution monitoring, smoke detection and tunnel ventilation control. The sensor uses infrared light with a forward scatter angle of 39° to 51° for visibility measurement.

The RWS-30 supports RS232, RS422 or RS485 serial communication, alongside 0…10 V and selectable 0…20 mA or 4…20 mA analog outputs. Optional volt-free relays provide one fault relay and two configurable threshold relays for monitoring and control applications. Automatic window contamination correction and two-stage cleaning warnings support maintenance planning. The sensor features a powder-coated aluminium housing rated IP66/IP67, operates from −40 to +60 °C and requires a 9…36 Vdc power supply.

Typical Applications

  • Road and highway visibility monitoring for fog detection

  • Tunnel air pollution and smoke detection

  • Tunnel ventilation control based on visibility thresholds

  • Road Weather Information Systems (RWIS) integration

  • Tunnel safety alarms and entrance warning sign activation

Key Features

  • Infrared forward scatter visibility measurement with 39° to 51° scattering angle

  • Meteorological Optical Range (MOR) measurement from 200 m to 99.99 km

  • Atmospheric extinction coefficient (EXCO) measurement from 0.03 to 15 km⁻¹

  • Selectable MOR measurement resolution of 1 m or 10 m

  • RS232, RS422 or RS485 serial communication interface

  • 0…10 V and selectable 0…20 mA or 4…20 mA analog outputs

  • Optional three volt-free relays comprising one fault relay and two configurable threshold relays

  • Automatic window contamination correction with two-stage cleaning warnings

  • Built-in self-test and diagnostic monitoring

  • Window heating to reduce condensation

  • Powder-coated aluminium housing with IP66/IP67 protection

  • Operating temperature range of −40…+60 °C

  • 9…36 Vdc sensor power supply

  • Pole mounting with supplied U-bolts for 40…64 mm diameter poles

  • Factory calibration traceable to a national weather service transmissometer

Benefits

  • Early identification of reduced visibility caused by fog, pollution and smoke

  • MOR and EXCO measurements from one sensor for road and tunnel monitoring

  • Supports tunnel ventilation control, safety alarms and entrance warning signs

  • Flexible integration with monitoring and control systems through serial and analog outputs

  • More efficient maintenance planning through automatic contamination correction and two-stage cleaning warnings

  • Reliable operation in demanding road and tunnel environments with IP66/IP67 protection

  • Simplified installation with compact design and supplied pole-mounting hardware

  • Confidence in long-term measurements through traceable factory calibration

Specifications

Visibility Measurement

Measurement principle

Infrared forward scatter

Measured parameters

Meteorological Optical Range (MOR) and atmospheric extinction coefficient (EXCO)

MOR measurement range

200 m to 99.99 km

EXCO measurement range

0.03 to 15 km⁻¹

MOR measurement resolution

1 m or 10 m (default)

Measurement error (datasheet)

≤10% at 200–10,000 m; ≤20% at 10,001–30,000 m

Measurement accuracy (manual)

Better than ±10% at MOR ≈10 km; better than ±15% at MOR ≈20 km; better than ±20% at MOR ≈30 km

Measurement time constant

10–300 seconds, user-configurable (default 60 seconds)

MOR zero stability – ambient temperature effect

≤0.02 km⁻¹

MOR zero stability – long-term drift

≤0.02 km⁻¹

 

 

Optical Sensor Characteristics

Scattering angle

45° with ±6° cone angle

Sample volume

400 cm³

Light source

Infrared emitting diode (IRED)

Central wavelength

0.85 µm

Light source bandwidth

0.04 µm

Light source lifetime

Greater than 10 years

Modulation frequency

2,000 Hz

Photodiode detector

Silicon (photovoltaic)

Photodiode filter bandwidth

0.08 µm at 0.85 µm

 

 

Internal Temperature Sensor

Sensor type

Circuit-mounted IC

Temperature range

−40 to +60 °C

 

 

Digital Communication Interface

Primary serial interface

RS232C (full duplex), RS422 or RS485

Secondary serial interface

RS232C (full duplex)

Data format

ASCII

Baud rate

1,200 to 57,600 baud, user-selectable

Data bits

8

Parity

None

Stop bits

1

Flow control

None

Message termination

CR, LF

Default output rate

60 seconds

 

 

Analog Outputs

Voltage output

0–10 Vdc

Voltage output load (manual designation)

10 kΩ

Current output

0–20 mA or 4–20 mA, user-selectable

Current output maximum resistance

500 Ω

Output scaling

0 to MORMAX

 

 

Relay Outputs (Optional)

Relay configuration

1 fault relay and 2 threshold relays

Fault relay

Normally energised; releases on fault condition

Relay 1

Normally de-energised; adjustable visibility threshold from 0.10 km to MORMAX

Relay 1 default threshold

1 km

Relay 2

Normally de-energised; adjustable visibility threshold from 0.10 km to MORMAX, or window contamination

Relay 2 default threshold

1 km

Relay terminals

Common, normally closed (NC) and normally open (NO)

Maximum switching voltage

220 Vdc / 250 Vac

Maximum switching current

2 A (resistive load)

Maximum switching power

60 W / 125 VA

Contact material

Silver alloy with gold alloy overlay

 

 

Power Requirements

Sensor supply voltage

9–36 Vdc (24 Vdc typical)

Basic sensor power consumption

3.5 W

Window heater power consumption

1.7 W

Window heater power supply

Supplied from sensor power

Hood heater supply voltage

24 Vdc / 24 Vac

Hood heater power consumption

24 W

 

 

Environmental

Operating temperature

−40 to +60 °C

Operating humidity

0–100%

Altitude

0–15,000 ft

Precipitation

All weather

Protection rating

IP66/IP67

 

 

Maintenance and Calibration

Window contamination monitoring

Standard on both sensor head windows

Contamination correction

Automatic

Cleaning warnings

Two-stage

Self-test and diagnostics

Built-in

Typical calibration check interval

12 months

Typical window cleaning interval

3 months

Calibration traceability

National weather service transmissometer

Optional calibration kit

SWS.CAL – SWS and RWS Series Calibration Kit

 

 

Physical Properties and Installation

Housing material

Powder-coated aluminium

Weight

3.8 kg

Weight including pole mounting kit

4.3 kg

Length (operating manual)

315 mm

Width (operating manual)

811 mm

Depth (operating manual)

330 mm, including pole mounting kit

Compatible mounting pole diameter

40–64 mm

Supplied mounting hardware

2 U-bolts for pole mounting

 

 

Certification and Compliance

CE certification

CE certified

EMC compliance (operating manual)

EN 61326-1:2021

EMC compliance (datasheet)

EN 61326-1997, 1998, 2001

RoHS compliance

Compliant

WEEE compliance

Compliant

Tunnel guidelines

PIARC guidelines

 

 

Warranty and Product Lifetime

Standard warranty

2 years

Stated product lifetime

Greater than 10 years

Optional extended warranty

RWS.WTY – 1-year extended warranty

Drawing

RWS-30 Visibility Sensor Drawing

Downloads

RWS-30 Family Datasheet DownloadRWS-30 Family Datasheet
RWS-30 Family User Manual DownloadRWS-30 Family User Manual