WETEC
VPF-710 Visibility Sensor thumbnail 1
VPF-710 Visibility Sensor thumbnail 2
VPF-710 Visibility Sensor thumbnail 3

Senseca

VPF-710 Visibility Sensor


High-performance forward scatter visibility sensor for reliable monitoring in demanding weather conditions.

  • Visibility measurement range of 10 m…99.99 km

  • Extinction Coefficient (EXCO) output as standard, with Meteorological Optical Range (MOR) available as a special configuration

  • RS232 serial output as standard, with optional RS422/RS485

  • Standard window heaters and transmitter window contamination monitoring

  • Optional hood heaters and interface for the ALS-2 ambient light sensor

  • Hard coat anodised aluminium enclosure with IP66 protection

  • Operating temperature range of -50…+60 °C

Quantity
1

Overview

The Senseca VPF-710 is a high-performance forward scatter visibility sensor designed for demanding applications such as offshore platforms, airports and wind farms. Its open-head design allows free airflow through the measurement volume, providing representative visibility measurements in conditions involving rain, snow, fog, smoke and dust. The sensor measures visibility from 10 m to 99.99 km, reporting Extinction Coefficient (EXCO) as standard or Meteorological Optical Range (MOR) through a special configuration.

The VPF-710 provides RS232 serial output as standard, with optional RS422/RS485 communication for integration with data collection and processing systems. Standard window heaters, transmitter window contamination monitoring and automatic compensation support reliable operation with reduced maintenance requirements. The sensor features a hard coat anodised aluminium enclosure with IP66 protection, operates from -50 to +60 °C and is available with DC or AC power supplies. Optional hood heaters, receiver window contamination monitoring and an interface for the ALS-2 ambient light sensor are available.

Typical Applications

  • Airport visibility and Runway Visual Range (RVR) monitoring

  • Visibility monitoring on offshore platforms

  • Visibility monitoring at wind farms

  • Wind turbine obstacle warning light control

  • Visibility measurement in fog, rain, snow, smoke and dust

  • Visibility data integration into weather monitoring and processing systems

Key Features

  • Forward scatter visibility measurement with 39°…51° scattering angle, centred at 45°

  • Visibility measurement range of 10 m…99.99 km

  • Extinction Coefficient (EXCO) output as standard, with Meteorological Optical Range (MOR) available as a special configuration

  • RS232 serial output as standard, with optional RS422/RS485

  • Selectable data output intervals from 10…300 seconds

  • Open-head design allowing free airflow through the measurement volume

  • Standard window heaters with optional hood heaters

  • Transmitter window contamination monitoring and automatic compensation, with optional receiver window monitoring

  • Built-in self-test and monitoring, with standard and advanced configurations

  • Optional interface for ALS-2 ambient light sensor

  • Hard coat anodised aluminium enclosure with IP66 protection

  • Operating temperature range of -50…+60 °C

  • Available with 12 Vdc, 24 Vdc, 120 Vac or 240 Vac power supplies

  • Supplied 6 m power and data cables

  • Calibration in accordance with ICAO 9328, traceable to a national weather service transmissometer

Benefits

  • Reliable visibility measurements in rain, snow, fog, smoke and dust

  • Wide measurement range supports both short- and long-distance visibility monitoring

  • Flexible serial communication enables integration with different data collection systems

  • Automatic window contamination compensation and cleaning warnings reduce maintenance requirements

  • Standard window heaters help maintain measurement performance in adverse conditions

  • Corrosion-resistant construction supports long-term operation in harsh environments

  • Built-in self-test functions help identify sensor faults and support operational confidence

  • Optional ALS-2 interface enables combined visibility and ambient light data for RVR processing

  • Compact design and supplied cables simplify field installation

Specifications

Visibility Measurement

Measured parameter

Visibility

Measurement principle

Forward scatter meter

Scattering angle

39°…51°, centred at 45°

Visibility range

10 m…99.99 km

Standard reported measurement

Extinction Coefficient (EXCO)

Special configuration

Meteorological Optical Range (MOR)

Measurement error at 600 m

≤1.3%

Measurement error at 1,500 m

≤1.8%

Measurement error at 2 km

≤2.0%

Measurement error at 15 km

≤8.3%

Measurement error at 30 km

≤10.5%

Measurement error at 75 km

≤20%

Calibration method

In accordance with ICAO 9328

Calibration traceability

National weather service transmissometer

 

 

Serial Outputs and Data Communication

Output type

Serial data

Standard serial output

RS232

Optional serial output

RS422/RS485

Selectable output interval

10…300 seconds

Data transmission

Automatic or polled

Message formats

Expanded or compressed

RS485 sensor address range

00…99

RS232/RS422 checksum

Optional

RS485 checksum

Longitudinal Redundancy Check (LRC)

Default baud rate

1200 baud

Selectable baud rates

1200, 2400, 4800, 9600, 19200, 38400, 57600 baud

Default data bits

8

Default stop bits

1

Default parity

None

Default flow control

None

Configuration

Direct sensor commands or Sensor Interface Software

 

 

Power Requirements

Sensor power supply options

12 Vdc / 24 Vdc / 120 Vac / 240 Vac

Basic sensor power

6 W

Hood heater power

30 W (17 W for 12 V sensor)

Hood heating supply

As sensor supply

 

 

Heating and Contamination Monitoring

Window heaters

Fitted as standard

Hood heaters

Optional

Transmitter window contamination monitoring

Fitted as standard

Receiver window contamination monitoring

Optional

Contamination compensation

Automatic

Cleaning warnings

Two-stage

Hood heater operating modes

Disabled or automatic

Window heater operating modes

Disabled, permanently enabled or controlled according to contamination levels

 

 

Self-Test and Monitoring

Self-test and monitoring configuration

Standard or advanced

Self-test information

Included in data messages

Window contamination status

Included in data messages

Functional test mode

Simulation of visibility, contamination and fault conditions

 

 

Environmental

Operating temperature

−50…+60 °C

Operating humidity

0…100% RH

Protection rating

IP66

 

 

Physical

Material

Hard coat anodised aluminium

Weight — DC sensor

4.9 kg

Weight — AC sensor

6.1 kg

Overall width

751 mm

Overall height

520 mm

Side depth

224 mm

Base diameter

Ø114 mm

 

 

Optional Ambient Light Sensor

Compatible ambient light sensor

ALS-2

ALS-2 interface

Optional

Ambient light measurement range

2…40,000 cd/m²

ALS-2 connection cable

1 m

Ambient light data output

Appended to sensor data string

Luminance data format

Five-digit ASCII character string

Supported processing

Runway Visual Range (RVR)

 

 

Cables and Installation

Standard power cable

6 m

Standard data cable

6 m

Optional cable length

Up to 25 m

Combined power and data cable

Optional for 12 Vdc or 24 Vdc sensors configured for RS232

Cable termination

Connectors or optional permanently connected cables via glands

Supplied mounting kit

Pole mounting kit (1 × U-bolt)

 

 

Certification and Compliance

CE certification

CE certified

EMC compliance

EN61326-1997, 1998, 2001

Environmental compliance

RoHS and WEEE compliant

 

 

Warranty and Service Life

Warranty

5 years

Lifetime

Greater than 10 years

Calculated MTBF

Over 6 years

 

 

Optional Accessories Part Number

70.CAL

VPF Series Calibrator

VPF.TEST1

VPF Test Plaque (single-stage test kit)

VPF.TEST2

VPF Test Plaque (two-stage test kit)

71.WTY

1 Year Extended Warranty

Drawing

VPF-710 Visibility Sensor Drawing

Downloads

VPF-710 Family Datasheet DownloadVPF-710 Family Datasheet
VPF-Series Family User Manual DownloadVPF-Series Family User Manual