Senseca
VPF-710 Visibility Sensor
High-performance forward scatter visibility sensor for reliable monitoring in demanding weather conditions.
Visibility measurement range of 10 m…99.99 km
Extinction Coefficient (EXCO) output as standard, with Meteorological Optical Range (MOR) available as a special configuration
RS232 serial output as standard, with optional RS422/RS485
Standard window heaters and transmitter window contamination monitoring
Optional hood heaters and interface for the ALS-2 ambient light sensor
Hard coat anodised aluminium enclosure with IP66 protection
Operating temperature range of -50…+60 °C
Overview
The Senseca VPF-710 is a high-performance forward scatter visibility sensor designed for demanding applications such as offshore platforms, airports and wind farms. Its open-head design allows free airflow through the measurement volume, providing representative visibility measurements in conditions involving rain, snow, fog, smoke and dust. The sensor measures visibility from 10 m to 99.99 km, reporting Extinction Coefficient (EXCO) as standard or Meteorological Optical Range (MOR) through a special configuration.
The VPF-710 provides RS232 serial output as standard, with optional RS422/RS485 communication for integration with data collection and processing systems. Standard window heaters, transmitter window contamination monitoring and automatic compensation support reliable operation with reduced maintenance requirements. The sensor features a hard coat anodised aluminium enclosure with IP66 protection, operates from -50 to +60 °C and is available with DC or AC power supplies. Optional hood heaters, receiver window contamination monitoring and an interface for the ALS-2 ambient light sensor are available.
Typical Applications
Airport visibility and Runway Visual Range (RVR) monitoring
Visibility monitoring on offshore platforms
Visibility monitoring at wind farms
Wind turbine obstacle warning light control
Visibility measurement in fog, rain, snow, smoke and dust
Visibility data integration into weather monitoring and processing systems
Key Features
Forward scatter visibility measurement with 39°…51° scattering angle, centred at 45°
Visibility measurement range of 10 m…99.99 km
Extinction Coefficient (EXCO) output as standard, with Meteorological Optical Range (MOR) available as a special configuration
RS232 serial output as standard, with optional RS422/RS485
Selectable data output intervals from 10…300 seconds
Open-head design allowing free airflow through the measurement volume
Standard window heaters with optional hood heaters
Transmitter window contamination monitoring and automatic compensation, with optional receiver window monitoring
Built-in self-test and monitoring, with standard and advanced configurations
Optional interface for ALS-2 ambient light sensor
Hard coat anodised aluminium enclosure with IP66 protection
Operating temperature range of -50…+60 °C
Available with 12 Vdc, 24 Vdc, 120 Vac or 240 Vac power supplies
Supplied 6 m power and data cables
Calibration in accordance with ICAO 9328, traceable to a national weather service transmissometer
Benefits
Reliable visibility measurements in rain, snow, fog, smoke and dust
Wide measurement range supports both short- and long-distance visibility monitoring
Flexible serial communication enables integration with different data collection systems
Automatic window contamination compensation and cleaning warnings reduce maintenance requirements
Standard window heaters help maintain measurement performance in adverse conditions
Corrosion-resistant construction supports long-term operation in harsh environments
Built-in self-test functions help identify sensor faults and support operational confidence
Optional ALS-2 interface enables combined visibility and ambient light data for RVR processing
Compact design and supplied cables simplify field installation
Specifications
Visibility Measurement | |
|---|---|
Measured parameter | Visibility |
Measurement principle | Forward scatter meter |
Scattering angle | 39°…51°, centred at 45° |
Visibility range | 10 m…99.99 km |
Standard reported measurement | Extinction Coefficient (EXCO) |
Special configuration | Meteorological Optical Range (MOR) |
Measurement error at 600 m | ≤1.3% |
Measurement error at 1,500 m | ≤1.8% |
Measurement error at 2 km | ≤2.0% |
Measurement error at 15 km | ≤8.3% |
Measurement error at 30 km | ≤10.5% |
Measurement error at 75 km | ≤20% |
Calibration method | In accordance with ICAO 9328 |
Calibration traceability | National weather service transmissometer |
Serial Outputs and Data Communication | |
|---|---|
Output type | Serial data |
Standard serial output | RS232 |
Optional serial output | RS422/RS485 |
Selectable output interval | 10…300 seconds |
Data transmission | Automatic or polled |
Message formats | Expanded or compressed |
RS485 sensor address range | 00…99 |
RS232/RS422 checksum | Optional |
RS485 checksum | Longitudinal Redundancy Check (LRC) |
Default baud rate | 1200 baud |
Selectable baud rates | 1200, 2400, 4800, 9600, 19200, 38400, 57600 baud |
Default data bits | 8 |
Default stop bits | 1 |
Default parity | None |
Default flow control | None |
Configuration | Direct sensor commands or Sensor Interface Software |
Power Requirements | |
|---|---|
Sensor power supply options | 12 Vdc / 24 Vdc / 120 Vac / 240 Vac |
Basic sensor power | 6 W |
Hood heater power | 30 W (17 W for 12 V sensor) |
Hood heating supply | As sensor supply |
Heating and Contamination Monitoring | |
|---|---|
Window heaters | Fitted as standard |
Hood heaters | Optional |
Transmitter window contamination monitoring | Fitted as standard |
Receiver window contamination monitoring | Optional |
Contamination compensation | Automatic |
Cleaning warnings | Two-stage |
Hood heater operating modes | Disabled or automatic |
Window heater operating modes | Disabled, permanently enabled or controlled according to contamination levels |
Self-Test and Monitoring | |
|---|---|
Self-test and monitoring configuration | Standard or advanced |
Self-test information | Included in data messages |
Window contamination status | Included in data messages |
Functional test mode | Simulation of visibility, contamination and fault conditions |
Environmental | |
|---|---|
Operating temperature | −50…+60 °C |
Operating humidity | 0…100% RH |
Protection rating | IP66 |
Physical | |
|---|---|
Material | Hard coat anodised aluminium |
Weight — DC sensor | 4.9 kg |
Weight — AC sensor | 6.1 kg |
Overall width | 751 mm |
Overall height | 520 mm |
Side depth | 224 mm |
Base diameter | Ø114 mm |
Optional Ambient Light Sensor | |
|---|---|
Compatible ambient light sensor | ALS-2 |
ALS-2 interface | Optional |
Ambient light measurement range | 2…40,000 cd/m² |
ALS-2 connection cable | 1 m |
Ambient light data output | Appended to sensor data string |
Luminance data format | Five-digit ASCII character string |
Supported processing | Runway Visual Range (RVR) |
Cables and Installation | |
|---|---|
Standard power cable | 6 m |
Standard data cable | 6 m |
Optional cable length | Up to 25 m |
Combined power and data cable | Optional for 12 Vdc or 24 Vdc sensors configured for RS232 |
Cable termination | Connectors or optional permanently connected cables via glands |
Supplied mounting kit | Pole mounting kit (1 × U-bolt) |
Certification and Compliance | |
|---|---|
CE certification | CE certified |
EMC compliance | EN61326-1997, 1998, 2001 |
Environmental compliance | RoHS and WEEE compliant |
Warranty and Service Life | |
|---|---|
Warranty | 5 years |
Lifetime | Greater than 10 years |
Calculated MTBF | Over 6 years |
Optional Accessories Part Number | |
|---|---|
VPF Series Calibrator | |
VPF.TEST1 | VPF Test Plaque (single-stage test kit) |
VPF.TEST2 | VPF Test Plaque (two-stage test kit) |
71.WTY | 1 Year Extended Warranty |
Drawing

Downloads
| VPF-710 Family Datasheet | DownloadVPF-710 Family Datasheet |
|---|---|
| VPF-Series Family User Manual | DownloadVPF-Series Family User Manual |
Related Products

Senseca
SEMS-2000 Solar Energy Measurement System
Compact 2-axis solar tracking system for automatic DNI, DHI and GHI monitoring with suitable sensors.
Learn More
Senseca
HDMCS-100 Compact Weather Station
Compact, self-powered automatic weather station for wind, temperature, humidity, pressure and rainfall monitoring.
Learn More
Senseca
GEO-MDFS2 Dust Fall Monitoring System
Dust fall monitoring system for PV panel cleaning decisions.
Learn More
Senseca
VNR 21/22 Conductive Level Signal Amplifier
Signal amplifier for SL series conductive level probes.
Learn More