Senseca
VPF-730 Visibility and Present Weather Sensor
Visibility and present weather sensor for offshore and aviation applications.
Forward scatter MOR and EXCO measurement range of 10 m…99.99 km
Dedicated backscatter receiver for liquid and frozen precipitation identification
15 WMO Table 4680 and 17 METAR present weather codes
RS-232 standard output, with optional RS-422/RS-485
IP66 hard coat anodised aluminium housing
Automatic window contamination monitoring with two-stage cleaning warnings
Standard window heaters and optional hood heating
Overview
The Senseca VPF-730 is a visibility and present weather sensor designed for offshore platforms, heli-decks and aviation sites. Its compact, open-head design maintains a well-ventilated sample volume, while the hard coat anodised aluminium construction provides corrosion resistance and durability in harsh environments.
The sensor uses forward scatter technology to measure Meteorological Optical Range (MOR) and Extinction Coefficient (EXCO) over a visibility range of 10 m to 99.99 km. A dedicated backscatter receiver improves the distinction between liquid and frozen precipitation, enabling the reporting of 15 WMO Table 4680 and 17 METAR present weather codes. Calibration is traceable to a national weather service transmissometer in accordance with ICAO 9328.
The VPF-730 incorporates automatic window contamination monitoring with two-stage cleaning warnings, standard window heaters and optional hood heating to reduce maintenance requirements. It features RS-232 serial communication as standard, with optional RS-422/RS-485 outputs and an ALS-2 Ambient Light Sensor interface for Runway Visual Range (RVR) applications. The sensor has an IP66 protection rating and operates within a temperature range of −40 to +60 °C.
Typical Applications
Visibility and present weather monitoring at offshore platforms and heli-decks
Airport and runway visibility monitoring
Runway Visual Range (RVR) systems with optional ambient light sensor integration
Liquid and frozen precipitation identification
National meteorological observation networks
Visibility and present weather monitoring for research applications
Key Features
Forward scatter measurement of Meteorological Optical Range (MOR) and Extinction Coefficient (EXCO)
Visibility measurement range of 10 m…99.99 km
Dedicated backscatter receiver for improved liquid and frozen precipitation identification
Reports 15 WMO Table 4680 and 17 METAR present weather codes
Calibration traceable to a national weather service transmissometer in accordance with ICAO 9328
Compact, open-head design for effective sample volume ventilation
Hard coat anodised aluminium construction with IP66 protection rating
Operating temperature range of −40…+60 °C
Automatic window contamination monitoring with two-stage cleaning warnings
Standard window heaters with optional hood heating
RS-232 serial output as standard, with optional RS-422/RS-485 communication
Optional ALS-2 Ambient Light Sensor interface for Runway Visual Range (RVR) applications
Selectable data output interval of 10…300 seconds
Power supply configurations of 12 Vdc, 24 Vdc, 120 Vac or 240 Vac
Benefits
Visibility and present weather measurements from a single sensor
Improved separation of liquid and frozen precipitation for reliable weather classification
Representative measurements in driving rain, spray and dust through a well-ventilated open-head design
Corrosion-resistant construction for long service life in harsh offshore and aviation environments
Reduced maintenance requirements through automatic window contamination monitoring and two-stage cleaning warnings
Standard window heaters and optional hood heating for operation in demanding weather conditions
Flexible integration with monitoring systems through standard RS-232 and optional RS-422/RS-485 communication
Supports Runway Visual Range (RVR) applications through optional ALS-2 Ambient Light Sensor integration
Traceable visibility calibration supporting aviation applications in accordance with ICAO 9328
Specifications
Visibility Measurement | |
|---|---|
Measured parameters | Visibility and Present Weather (MOR & EXCO) |
Visibility range | 10 m to 99.99 km |
Measurement principle | Forward scatter meter |
Measurement angle | 39° to 51°, centred at 45° |
Calibration traceability | National weather service transmissometer, in accordance with ICAO 9328 |
Visibility Measurement Error | |
|---|---|
600 m | ≤1.3% |
1,500 m | ≤1.8% |
2 km | ≤2.0% |
15 km | ≤8.3% |
30 km | ≤10.5% |
75 km | ≤20% |
Precipitation Measurement | |
|---|---|
Precipitation type determination | Particle intensity and transit time combined with forward/backscatter ratio |
Rain detection resolution | 0.015 mm/h (0.0006 in/h) |
Snow detection resolution | 0.0015 mm/h (0.00006 in/h) |
Precipitation intensity reporting range | 0 to 1000 mm/h (39.4 in/h) |
Rain intensity accuracy | ≤10% |
Data Output & Present Weather Reports | |
|---|---|
Output | Serial data |
Output rate | 10 to 300 seconds, selectable |
Standard serial output | RS232 |
Optional serial output | RS422/RS485 |
WMO present weather reporting | 15 WMO Table 4680 codes |
METAR present weather reporting | 17 METAR codes |
Power Requirements | |
|---|---|
Sensor power supply | 12 Vdc / 24 Vdc / 120 Vac / 240 Vac |
Basic sensor power consumption | 6 W |
Hood heating power supply | As sensor supply |
Hood heater power consumption | 45 W (25.5 W for 12 V sensor) |
Heating & Window Contamination Monitoring | |
|---|---|
Window heaters | Fitted as standard |
Hood heaters | Optional |
Transmitter window contamination monitoring | Fitted as standard |
Receiver window contamination monitoring | Optional |
Window contamination warnings | Two-stage warning and alert |
Default contamination warning threshold (WT) | 10% |
Default contamination alert threshold (WF) | 30% |
Environmental | |
|---|---|
Operating temperature | −40 °C to +60 °C |
Operating humidity | 0 to 100% RH |
Protection rating | IP66 |
Physical | |
|---|---|
Material | Hard coat anodised aluminium |
Weight — DC sensors | 5.6 kg |
Weight — AC sensors | 6.8 kg |
Length | 751 mm |
Lifetime | >10 years |
Warranty | 5 years |
Certification & Compliance | |
|---|---|
CE certification | CE Certified |
EMC compliance | EN61326-1997, 1998, 2001 |
RoHS | Compliant |
WEEE | Compliant |
Optional Interfaces | |
|---|---|
ALS-2 Ambient Light Sensor interface | Optional |
Weather Station Module | Optional, with analogue meteorological inputs |
Ordering & Configuration Options | Ordering code | Description |
|---|---|---|
Power supply | 012 | 12 Vdc |
Power supply | 024 | 24 Vdc |
Power supply | 120 | 120 Vac |
Power supply | 240 | 240 Vac |
Hood heating | NH | Without heating |
Hood heating | HV | With heating |
Data output | D | RS232 serial output |
Data output | E | RS422/RS485 serial output |
Self-test and monitoring | S | Standard self-test and monitoring |
Self-test and monitoring | A | Advanced self-test and monitoring |
ALS-2 interface | NA | Without option board |
ALS-2 interface | WA | With ALS-2 interface |
Cable connection | 06 | 6 m power and data cables with connectors |
Cable connection | 06G | 6 m power and data cables, hard wired |
Precipitation definitions | XX | Country code |
Configuration | RC | Regular configuration |
Configuration | SC | Special configuration |
Supplied Items | |
|---|---|
Mounting kit | Pole mounting kit (1 × U-bolt) |
Power and data cable | 6 m |
User documentation | User manual |
Calibration documentation | Calibration certificates |
Packaging | Sturdy recyclable foam-filled packaging |
Optional Accessories Part Number | |
|---|---|
70.CAL | VPF Series Calibrator |
VPF.TEST1 | VPF Test Plaque (single-stage test kit) |
VPF.TEST2 | VPF Test Plaque (two-stage test kit) |
73.WTY | 1 Year Extended Warranty |
PW.CODE | User-defined precipitation definitions |
Drawing

Downloads
| VPF-730 Family Datasheet | DownloadVPF-730 Family Datasheet |
|---|---|
| VPF-Series Family User Manual | DownloadVPF-Series Family User Manual |
| PW-Sensor-Country-Code-List Family Operating Instructions | DownloadPW-Sensor-Country-Code-List Family Operating Instructions |
Related Products

Senseca
SEMS-2000 Solar Energy Measurement System
Compact 2-axis solar tracking system for automatic DNI, DHI and GHI monitoring with suitable sensors.
Learn More
Senseca
HDMCS-100 Compact Weather Station
Compact, self-powered automatic weather station for wind, temperature, humidity, pressure and rainfall monitoring.
Learn More
Senseca
GEO-MDFS2 Dust Fall Monitoring System
Dust fall monitoring system for PV panel cleaning decisions.
Learn More
Senseca
VNR 21/22 Conductive Level Signal Amplifier
Signal amplifier for SL series conductive level probes.
Learn More