WETEC

Solinst

3001 Barologger 6


Barometric pressure and temperature datalogger used to compensate Levelogger water level data.

  • Air pressure measurement in psi, kPa or mbar with ±0.05 kPa accuracy
  • Pressure algorithms based on air rather than water pressure for superior accuracy
  • 150,000 data sets of memory plus a dedicated 20,000-reading backup, with a 10-year battery
Quantity
1

Overview

The Barologger 6 records atmospheric pressure and temperature on site. Set above high water level in one location, it is used to compensate Levelogger data for atmospheric pressure fluctuations, avoiding time lag in the compensation.

Typical applications

  • Barometric compensation of Levelogger 6, 5, Edge and Junior data
  • Site-wide barometric compensation: one Barologger compensates all Leveloggers within a 30 km (20 mile) radius and/or with every 300 m (1000 ft) change in elevation
  • Determining barometric lag and/or barometric efficiency of the monitored aquifer

Key Features

  • Records atmospheric pressure in psi, kPa or mbar, plus temperature in °C or °F
  • ±0.05 kPa accuracy with 0.002% FS resolution
  • Pressure algorithms based on air rather than water pressure
  • Backwards compatible: Levelogger Software recognizes the Levelogger type and compensates using the same units as the submerged data file
  • 150,000 sets of readings with a dedicated 20,000-reading backup memory
  • 10-year battery life (based on 1 reading/minute)
  • Linear, event and user-selectable sampling with repeat mode, future start, future stop and real-time view
  • Measurement rates from 1/8 second to 99 hours

Benefits

  • No Time Lag: compensating with a Barologger 6 is the most accurate method of obtaining changes in water level, avoiding time lag in the compensation.
  • Site-Wide Coverage: one Barologger can compensate all Leveloggers within a 30 km (20 mile) radius and/or with every 300 m (1000 ft) change in elevation.
  • Automatic Compensation: the Levelogger Software Data Wizard automatically produces compensated data files using synchronized data files from the Barologger and Leveloggers on site.
  • Superior Accuracy: the Barologger 6 uses pressure algorithms based on air rather than water pressure.
  • Backwards Compatible: works with submerged Levelogger 6, 5, Edge and Junior data.
  • Aquifer Insight: the recorded barometric information can help determine barometric lag and/or barometric efficiency of the monitored aquifer.

Specifications

SPECIFICATIONS

 

Measurement

Air pressure only (atmospheric)

Level sensor

Piezoresistive silicon with Hastelloy® sensor

Accuracy

±0.05 kPa

Resolution

0.002% FS

Units of measure

psi, kPa, mbar, °C, °F

Normalization

Automatic temperature compensation

Temperature compensation range

-10°C to +50°C

Temperature sensor

Platinum Resistance Temperature Detector (RTD)

Temperature sensor accuracy

±0.05°C

Temperature sensor resolution

0.003°C

Battery life

10 years (based on 1 reading/minute)

Clock accuracy (typical)

±1 minute/year (-20°C to 80°C)

Operating temperature

-20°C to 80°C

Size

22 mm x 160 mm (7/8" x 6.3")

Weight

146 g (5.2 oz)

Corrosion resistance

Baked-on coating using polymerization technology (inside and out)

Other wetted materials

Delrin®, Viton®, 316L stainless steel, Hastelloy®, PFAS-free polymerization coating

 

 

DATA LOGGING

 

Maximum readings

150,000 sets of readings

Dedicated backup memory

20,000 sets of most recent readings

Memory mode

Slate and Continuous

Sampling modes

Linear, Event & User-Selectable with Repeat Mode, Future Start, Future Stop, Real-Time View

Measurement rates

1/8 sec to 99 hrs

Schedule option

Up to 30 schedule items, each with its own sampling rate and duration

Communication

Optical high-speed: USB, SDI-12, MODBUS (requires a surface Interface Cable for SDI-12 and MODBUS)
9600 bps; 57600 bps with USB Desktop/Field Reader; 19.2k baud with Mk3 USB-C PC Interface Cable

Compensation coverage

One Barologger 6 compensates all Leveloggers within approx. 30 km/20 miles radius and/or with every 300 m (1000 ft) change in elevation

 

 

DEPLOYMENT

 

Standard cable deployment

Stainless steel wireline or Kevlar® cord, available in a variety of lengths

Direct Read Cables

Available for attachment to any Levelogger in lengths up to 1500 ft. 3.175 mm dia. (1/8") coaxial cable with outer polyurethane jacket and stranded stainless steel conductor

2" Locking Well Cap

Fits standard and Direct Read Cable deployments; Well Cap insert has two openings for Levelogger and Barologger direct read cables; adaptors available for 4" wells; vented to equalize atmospheric pressure; secured with a lock with a 9.5 mm (3/8") shackle diameter

 

 

OPTIONS AND ACCESSORIES

 

Mk3 USB-C PC Interface Cable

Doubles communication speed to 19.2k baud, USB Type-C connector, LED status indicators, built-in self-test for Direct Read Cable faults, backwards compatible

Desktop Reader / Field Reader

Existing readers work with the Levelogger 6 single-eye optical interface

Levelogger App Interface

Bluetooth® connection between the Levelogger and the Solinst Levelogger App on a smart device

Solinst Readout Unit (SRU)

Displays instant water level readings and Levelogger status, saves real-time logging sessions, with automatic barometric compensation

DataGrabber

Field-ready USB data transfer unit; one push-button downloads all data in the Levelogger memory

SDI-12/MODBUS Interface Cable

Connects Leveloggers to an SDI-12 or MODBUS datalogger via a Direct Read Cable

Levelogger 6 Series Datasheet (EN) DownloadLevelogger 6 Series Datasheet (EN)
Levelogger 6 Series Quick Start Guide (EN) DownloadLevelogger 6 Series Quick Start Guide (EN)