WETEC

ECD

DCA-23 Seawater Dechlorination Analyzer


Seawater chlorination and dechlorination analyzer with dual-input potentiometric measurement.

  • Chlorine equivalent measurement range of 0.00…2.00 ppm

  • Minimum detection limit of 0.014 ppm

  • No added chemicals required

  • Flow-independent measurement

  • 4…20 mA output with optional alarm relays

  • Rack-mounted system for easy installation

Quantity
1

Overview

The ECD DCA-23 is a seawater chlorination and dechlorination analyzer featuring a dual-input potentiometric design. It measures pH, temperature and total residual oxidant (TRO) potential to determine the equivalent chlorine concentration over a range of 0.00…2.00 ppm, with a minimum detection limit of 0.014 ppm and a limit of quantification of 0.044 ppm.

The analyzer requires no added chemicals and is insensitive to flow variations. It is available as a complete rack-mounted system incorporating a T23 transmitter, sensors, piping and valves, or as separate components for custom installations. It provides 4…20 mA output with optional alarm relays and supports loop-powered, 24 Vdc, 110 Vac or 220 Vac configurations. The analyzer is specifically designed for seawater and is not suitable for freshwater applications.

Typical Applications

  • Seawater cooling systems in power plants and refineries

  • Seawater chlorination and dechlorination at desalination plants

  • Saltwater air conditioning (SWAC) systems

  • Seawater heat exchangers at LNG regasification terminals

  • Residual oxidant monitoring for seawater dechlorination compliance

Key Features

  • Dual-input potentiometric measurement design

  • Chlorine equivalent measurement range of 0.00…2.00 ppm

  • Minimum detection limit (MDL) of 0.014 ppm

  • Limit of quantification (LOQ) of 0.044 ppm

  • Measurement of pH, temperature and total residual oxidant (TRO) potential

  • No added chemicals required

  • Flow-independent measurement

  • T23 transmitter with 2 × 16-character LCD

  • 4…20 mA analogue output with optional dual SPDT alarm relays

  • Loop-powered, 24 Vdc, 110 Vac or 220 Vac configurations

  • NEMA 4X transmitter enclosure

  • Complete Uni-Strut rack-mounted system

  • Schedule 80 PVC piping

Benefits

  • No added chemicals required during measurement

  • Measurement unaffected by flow variations

  • Low detection limit for monitoring low residual oxidant concentrations

  • Easy installation with a preassembled rack-mounted system

  • Simple calibration by comparison with a free chlorine grab sample test

  • Flexible power supply and output configurations to suit different installation requirements

  • Separate components available for custom installations

  • Minimal maintenance requirements

Specifications

Measurement Performance

Measured parameters

pH, TRO potential and temperature

Chlorine equivalent measurement range

0.00…2.00 ppm

Minimum detection limit (MDL)

0.014 ppm

Limit of quantification (LOQ)

0.044 ppm

Flow sensitivity

None

Added chemicals

Not required

Calibration method

Comparison with a free chlorine grab sample test

Measurement medium

Seawater only

 

 

pH Sensor

Sensor model

PHS10-T23-CBL-EG-75PP

Measurement range

0…14 pH

Temperature range

0…80 °C

Pressure range

0…100 psig

Wetted materials

316 stainless steel, PES, Teflon, glass, Viton

 

 

TRO Sensor

Sensor model

MVS10-T23-CBL-EG-75PP

Measurement range

±1500 mV

Temperature range

0…80 °C

Pressure range

0…100 psig

Wetted materials (listed under TRS10 in datasheet)

316 stainless steel, PES, Teflon, platinum, Viton

 

 

Temperature Measurement

Measurement range

0…100 °C

 

 

T23 Transmitter

Display

LCD, 2 × 16 characters

Display size

4 × 1 in

Enclosure rating

NEMA 4X

Enclosure dimensions (L × W × D)

5.7 × 5.7 × 3.5 in

Keypad

Membrane switch keypad

Cable glands

2 × ½ in

 

 

Power Supply Part Number

1290220-1

Loop powered

1290200-2

24 Vdc (12…36 Vdc) at 0.05 A

1290200-3

24 Vdc (12…36 Vdc) at 0.10 A

1290200-4

110 Vac, 50/60 Hz

1290200-5

220 Vac, 50/60 Hz

 

 

Analogue Outputs

Output signal

4…20 mA

Maximum load

525 Ω

Output 1

Chlorine, 0.00…2.00 ppm (all models)

Output 2

pH, 0…14 pH (1290200-2, -3, -4 and -5)

 

 

Alarm Relays

Number of relays

2 (optional)

Applicable models

1290200-3, -4 and -5

Relay type

SPDT

Maximum AC contact rating

230 Vac / 5 A

Maximum DC contact rating

30 Vdc / 5 A

Load type

Resistive

 

 

Flow Train and Process Fittings

Compression fitting size

¾ in

Compression fitting materials

Polypropylene (PP), Viton

Pipe size

¾ in

Pipe tee size

1 in

Pipe and tee material

Schedule 80 PVC

Inlet and drain connections

Slip fittings

 

 

Rack-Mounted System

System components

T23 analyzer, two sensors, pH flow cell and TRO flow cell

Mounting rail

Uni-Strut rail

Mounting rail size

1⅝ × 1⅝ in

Maximum system pressure and temperature rating

50 psig at 60 °C

System dimensions (L × H × D)

26 × 20 × 8.5 in

 

 

Shipping Weight

T23 transmitter

4.8 lb

PHS10 or TRS10 sensor

2.5 lb

Complete rack-mounted system

18 lb

Drawing

DCA-23 Seawater Dechlorination Analyzer Drawing

Downloads

DCA-23 Instruction Manual DownloadDCA-23 Instruction Manual