Reagentless, panel-mounted analyzer for total chlorine measurement in water.

  • Measurement ranges: 0.05–20 ppm (high range) or 0.005–2.00 ppm (low range)

  • Three-electrode amperometric sensor

  • Automatic pH compensation and flow control

  • 4–20 mA output and Modbus RTU communication

  • Compliant with EPA Method 334.0

  • Optional automatic sensor cleaning

Quantity
1

Overview

The ECD TC80 Total Chlorine Analyzer is a reagentless, panel-mounted system designed to measure free and combined chlorine in water. It uses a three-electrode amperometric sensor with measurement ranges of 0.05–20 ppm (high range) or 0.005–2.00 ppm (low range). The system integrates a total chlorine sensor, pH sensor, constant head flow controller and T80 transmitter, providing automatic pH compensation and flow control.

The TC80 supports 4–20 mA outputs, Modbus RTU communication and configurable alarm relays, with 24 VDC or 100–240 VAC power supply options. The system is factory calibrated, complies with EPA Method 334.0 and features an optional automatic spray cleaning system. Its ready-to-use design simplifies installation.

Typical Applications

  • Total chlorine monitoring in drinking water

  • Total chlorine measurement in industrial cooling water

  • Total chlorine monitoring in industrial rinse water

  • Total chlorine measurement in wastewater

  • Chlorine disinfection monitoring in other freshwater systems

Key Features

  • Three-electrode amperometric sensor for total chlorine measurement

  • Measurement ranges of 0.05–20 ppm (high range) or 0.005–2.00 ppm (low range)

  • Automatic pH compensation within pH 4–12

  • Reagentless measurement technology

  • Automatic flow control using a constant head flow controller

  • Panel-mounted, ready-to-use system

  • 4–20 mA total chlorine output and optional 4–20 mA pH output

  • Modbus RTU communication

  • Configurable alarm relays

  • 24 VDC or 100–240 VAC power supply options

  • LCD with numerical and graphical displays

  • IP65 transmitter enclosure

  • Factory-calibrated system

  • Compliant with EPA Method 334.0

  • Optional automatic spray cleaning system

Benefits

  • Reduced operating costs by eliminating routine reagent consumption

  • Simplified installation with a complete panel-mounted system

  • Compensation for the effects of pH variations on chlorine measurements

  • Stable sample flow without additional pressure regulators or rotameters

  • Reduced risk of clogging and blockages with large flow tubes and cells

  • Easy integration with monitoring and control systems through analogue and digital outputs

  • Simplified commissioning with factory calibration

  • Convenient maintenance with tool-free membrane replacement and electrolyte refilling

  • Reduced sensor contamination with optional automatic spray cleaning

Specifications

Sensors and Flow Train

Measuring principle

Three-electrode amperometric sensing

Chlorine sensor

Potentiostatic sensor with digital protocol

Chlorine sensor electrodes

Gold cathode, silver/silver halide anode and stainless steel counter electrode

Sensor membrane

Microporous PTFE

pH sensor

Digital S80 protocol, 316L stainless steel body with replaceable electrode cartridge

Chlorine measurement range (high range)

0.05–20 ppm

Chlorine measurement range (low range)

0.005–2.00 ppm

pH measurement range

pH 4–14

Operating temperature

0–50 °C (32–122 °F)

Sample flow rate

38–300 L/h (10–80 gal/h)

Wetted materials

PVC, PP, PVDF, PTFE, glass and 316 stainless steel

Process inlet connection

¼″ FNPT with barb fitting

Process drain connection

¾″ FNPT

Response time

T90 in 2 minutes

Electrolyte life

3–6 months

 

 

TC80 Analyzer – Measurements and Display

Chlorine measurement range

0.00 ppb–22.00 ppm

pH measurement range

pH 0.00–14.00

pH compensation of total chlorine

pH 4–12

Display

LCD with LED backlight

Display resolution

128 × 64 pixels

Display dimensions

2.75″ × 1.5″

Display colour

Black on grey background; blue on white background with LED backlight on

Graphical display options

Bar, gauge or line

 

 

Outputs and Communication

Total chlorine output

One 4–20 mA output, set to the sensor measurement range

pH output

One optional 4–20 mA output, set to pH 0–14

Digital communication

Modbus RTU via RS485 (standard)

Alarm relays

Three SPDT, Form C relays

Relay configuration

High/low alarms with expiration timer, periodic timers or fault alarms

 

 

Input Power

DC power supply

24 VDC (18–36 VDC)

DC power requirement

250 mW minimum

AC power supply

100–240 VAC, 50/60 Hz

AC power consumption

4 W

Fuse protection

250 V, 1 A, slow-blow fuse

 

 

Enclosure

Enclosure material

Polycarbonate

Enclosure colour

Beige

Protection rating

IP65, weatherproof

Enclosure format

½ DIN

Dimensions (L × W × D)

14.4 × 14.4 × 9.0 cm (5.7″ × 5.7″ × 3.5″)

 

 

Environmental Conditions

Installation environment

Outdoor use with protective cover or sunshield

Ambient temperature (24 VDC models)

−20 to +70 °C

Ambient temperature (100–240 VAC models)

−20 to +60 °C

Storage temperature

−30 to +85 °C

Relative humidity

0–80% up to 31 °C, decreasing linearly to 50% RH at 40 °C

Maximum altitude

2,000 m (6,500 ft)

Mains supply voltage fluctuation

Up to ±10% of nominal voltage

Transient overvoltage category

CAT II

Pollution degree

2

 

 

Sample Requirements

Sample pressure

1–30 psig (0.1–2 bar)

 

 

System Configuration and Features

System configuration

Panel-mounted system

Integrated components

Total chlorine sensor, pH sensor, constant head flow controller, flow cells and T80 transmitter

Measurement technology

Reagentless

Flow control

Automatic

Calibration

Factory calibrated

Compliance

EPA Method 334.0

Automatic cleaning

Optional spray cleaner for the chlorine flow cell