BAROsense barometric pressure transmitter for environmental monitoring.
- Measures 300…1100 hPa with a piezoresistive sensor, ±0.5 hPa (700…1100 hPa) @ 20 °C
- RS485 Modbus-RTU output, with optional 0/4…20 mA or 0…1/5/10 V analog output and LCD display
- Optional T/RH probe input and static port with support bracket, IP 65, meets WMO requirements
Overview
The Senseca BAROsense PBS83M series is a barometric pressure transmitter with a high-precision piezoresistive pressure sensor and integrated temperature sensor, measuring 300…1100 hPa. It is factory calibrated in multiple points for excellent time stability and repeatability, and meets WMO requirements. The digital RS485 output with Modbus-RTU or proprietary ASCII protocol links the transmitter to sensor networks over extended distances, with an optional analog output configurable in current (0/4…20 mA) or voltage (0…1 V, 0…5 V or 0…10 V). Units of measurement are user-selectable, and an optional LCD display gives direct reading. Optional inputs for a combined temperature and relative humidity probe let it calculate dew point, absolute humidity and wet bulb temperature, and for outdoor installations an optional static port with support bracket minimises measurement errors caused by wind.
Typical applications
- Meteorological applications
- Environmental monitoring systems
- Altitude applications
- Barometric pressure compensation in internal combustion engines
- Cleanrooms
- Testing of vehicle emissions
Key Feature
- High-precision piezoresistive pressure sensor with integrated temperature sensor
- Measuring range 300…1100 hPa, configurable for analog output (default 600…1100 hPa)
- RS485 output with Modbus-RTU or ASCII proprietary protocol
- Optional analog output: 0/4…20 mA or 0…1 V, 0…5 V or 0…10 V, depending on model
- User-selectable units of measurement and optional LCD display
- Optional combined T/RH probe input, with calculated dew point, absolute humidity and wet bulb temperature
- Optional static port with support bracket for outdoor, wind-exposed installations
- Factory calibrated in multiple points; IP 65 polycarbonate housing
Benefits
- Reliability: factory-calibrated precision and outstanding stability for consistently accurate measurements
- According to the standard: meets WMO requirements
- Great flexibility: customise outputs and units to meet your measurement needs and integrate with existing systems
- Durability: built to withstand diverse environmental conditions, with an optional static port
- Wind-resistant: the optional static port minimises errors caused by wind flow in open field measurements
Specifications
BAROMETRIC PRESSURE |
|
Sensor | Piezoresistive |
Measuring range | 300…1100 hPa |
Resolution | 0.1 for the display |
Accuracy | ±0.5 hPa (700…1100 hPa) @ 20 °C |
Long-term stability | < ±1 hPa/year |
RELATIVE HUMIDITY (ONLY WITH EXTERNAL PROBE) |
|
Sensor | Capacitive |
Measuring range | 0…100 %RH |
Resolution | 0.1% |
Accuracy | ±2.5% (0…85%) / ±3.5% (85…100%) @ T = 23 °C |
Temperature drift | 0.05%/K (0…60 °C) |
Sensor operating temperature | -40…+105 °C (R.H. max = [100-2*(T-80)] @ T = 80…105 °C) |
Response time | T63 < 4 s (air speed = 2 m/s, without filter) |
Long-term stability | < 1%/year (@ 23 °C and 30…70 %RH) |
TEMPERATURE (ONLY WITH EXTERNAL PROBE) |
|
Sensor | PTAT integrated in humidity module |
Measuring range | -40…+105 °C |
Resolution | 0.1 °C |
Accuracy | ±0.2 °C in the range 0…+60 °C |
Long-term stability | 0.05 °C/year |
Calculated quantities | Dew point, absolute humidity and wet bulb temperature |
GENERAL SPECIFICATIONS |
|
Output | RS485 with Modbus-RTU or ASCII proprietary protocol |
Power supply | PBS83M0…: 7…30 Vdc |
Power consumption | 4 mA @ 24 Vdc (+ output current if current output is used) |
Connection | Internal screw terminal header / PG7 cable gland for power supply and output |
Operating conditions | -40…+60 °C (-20…+60 °C with LCD) |
Compatible media | Air and dry gases |
Material | Transmitter: polycarbonate, pressure input in nickel-plated brass |
Housing dimensions | 120 x 80 x 55 mm |
Weight | 250 g approx. (+ 570 g approx. for static port) |
Protection degree | IP 65 |
Static port mounting | Support bracket suitable for fixing to a Ø 30…50 mm mast |
ORDERING CODES | PBS83M [Analog output] [T/RH probe] [LCD] |
Additional analog output | 0 = no |
T / RH probe | 0 = no |
LCD | 0 = no |
FIXB001 | Static port with support bracket and silicone tube |
Downloads
| PBS83M Family Datasheet (EN) | DownloadPBS83M Family Datasheet (EN) |
|---|---|
| PBS83M Family User Manual (EN) | DownloadPBS83M Family User Manual (EN) |
Related Products

Senseca
HD2016 Weighing Rain Gauge
Weight-based rain gauge with load cell measurement, 0.001 mm resolution and ±0.2 mm accuracy.
Learn More
Senseca
BTD-200 Lightning Warning System
Self-contained lightning warning system detecting cloud-to-ground, intra-cloud and cloud-to-cloud lightning up to 35 km, with early overhead warning, 3 relays…
Learn More
Senseca
HD2013 Tipping Bucket Rain Gauge
HD2013 tipping bucket rain gauge for accurate rainfall monitoring, with corrosion-resistant construction, removable filter, optional heating and flexible…
Learn More
Senseca
BTD-1 Thunderstorm Warning System
Standalone thunderstorm warning system detecting lightning up to 35 km (83 km option) from the quasi-electrostatic field, with early warning, Severe Storm…
Learn More