RTD04 400 cm² Tipping-Bucket Precipitation Gauge


400 cm² tipping bucket rain gauge for meteorological and environmental monitoring.

  • Rainfall resolution of 0.1, 0.2 or 0.5 mm/tip, depending on model

  • Maximum rainfall rate of 600 or 1000 mm/h, depending on resolution

  • Contact, RS485, SDI-12, MOSFET Open Drain, 4…20 mA or 0…10 V outputs, depending on model

  • IP65 aluminum alloy housing; heated versions operate from -25…+70 °C

Quantity
1

Overview

The Senseca RTD04 is a tipping bucket rain gauge designed for accurate and reliable rainfall measurement in meteorological and environmental monitoring applications, following WMO-No. 8 recommendations. It features a 400 cm² collecting area with an aluminum collector cone that directs rainwater into a calibrated tipping bucket. Each bucket tip generates an electrical pulse for rainfall measurement, with resolution options of 0.1, 0.2 or 0.5 mm/tip and maximum rainfall rates of 600 or 1000 mm/h, depending on the selected resolution.

The RTD04 series offers flexible integration through voltage-free NC contact, RS485, SDI-12, MOSFET Open Drain, 4…20 mA or 0…10 V outputs, depending on the model. Its corrosion-resistant aluminum alloy housing provides IP65 protection for long-term outdoor operation, while a removable inlet filter and non-stick collector cone facilitate cleaning and maintenance. Heated versions operate from -25…+70 °C, with automatic heating activation around +4 °C to help prevent snow deposits and ice formation, supporting reliable rainfall measurement in cold weather conditions.

Typical Applications

  • Rainfall measurement in meteorological and environmental monitoring stations

  • High-intensity rainfall measurement up to 1000 mm/h, depending on model

  • Rainfall data collection through data loggers and pulse counters

  • Cold-weather precipitation monitoring using heated models

Key Features

  • 400 cm² rainfall collecting area

  • Calibrated tipping bucket mechanism with electrical pulse generation

  • Rainfall resolution of 0.1, 0.2 or 0.5 mm/tip, depending on model

  • Maximum rainfall rate of 600 or 1000 mm/h, depending on resolution

  • Designed according to WMO-No. 8 recommendations

  • Voltage-free NC contact, RS485, SDI-12, MOSFET Open Drain, 4…20 mA or 0…10 V outputs, depending on model

  • Integrated temperature, humidity, pressure and tilt sensors in digital and analog models

  • Corrosion-resistant aluminum alloy housing with IP65 protection

  • Removable inlet filter and non-stick collector cone

  • Heated versions operating from −25…+70 °C with automatic heating activation around +4 °C

  • Ø40…60 mm mast mounting with integrated bubble level

  • Factory calibrated with calibration value indicated on the instrument label

Benefits

  • Reliable rainfall measurement with a calibrated tipping bucket mechanism

  • Flexible output options to suit different monitoring systems

  • Reduced maintenance with removable filter and non-stick collector cone

  • Durable IP65 aluminum alloy construction for long-term outdoor use

  • Heated versions help prevent snow deposits and ice formation

  • Easier setup with factory calibration and integrated bubble level

  • Built-in diagnostics for monitoring instrument conditions in digital and analog models

Specifications

MEASUREMENT
Measuring principle Tipping bucket mechanism
Collecting area 400 cm²
Measurement resolution 0.1, 0.2 or 0.5 mm/tip, depending on model
Maximum rainfall rate 600 mm/h (0.1 and 0.2 mm/tip models); 1000 mm/h (0.5 mm/tip models)
Accuracy at nominal resolution ±2.5% from 0…100 mm/h (0.2 mm at 50 mm/h nominal resolution); ±1.5% from 0…100 mm/h (0.5 mm at 50 mm/h nominal resolution)
Accuracy using correction curves Typically less than ±2% up to 200 mm/h; less than ±4% above 200 mm/h
Measurement recommendations Designed according to WMO-No. 8
Calibration Factory calibrated; calibration value indicated on instrument label
OUTPUT AND COMMUNICATION
Voltage-free contact output Normally closed (NC) reed contact
Digital outputs RS485, SDI-12 and MOSFET Open Drain, depending on model
Analog outputs 4…20 mA or 0…10 V, depending on model
RS485 communication protocols Modbus-RTU or proprietary ASCII
Digital output protocols SDI-12 on RTD…F models
Electrical output connection M12 connector (5-pin for contact-only models; 8-pin for digital/analog models)
Measurement correction Automatic correction using stored curves in digital and analog models
ELECTRICAL
Supply voltage (digital/analog models) 7…30 Vdc
Supply voltage (contact-only models) No external power supply required for measurement
Current consumption (RTD…F and RTD…V models) Less than 7 mA at 24 Vdc, excluding heating
Current consumption (RTD…D models) Less than 29 mA at 24 Vdc, excluding heating
Contact-only model consumption No power consumption for the measuring circuit
Heater supply voltage 24 Vdc ±10%
Heater power consumption 110 W for RTD04 heated versions
HEATING AND OPERATING CONDITIONS
Operating temperature (without heating) 0…+70 °C
Operating temperature (with heating) −25…+70 °C
Heating activation temperature Approximately +4 °C
Heating control (digital/analog models) PID control
Heating control (contact-only models) ON/OFF control
Heating function Helps prevent snow deposits and ice formation
CONSTRUCTION AND PROTECTION
Housing material Anodized and painted aluminum alloy
Protection rating IP65
Collector Aluminum collector cone
Collector surface Non-stick treatment
Inlet filter Removable filter
Dimensions Ø256 × 457 mm
Weight Approximately 3 kg
INTEGRATED DIAGNOSTIC SENSORS
Temperature sensor Integrated temperature monitoring
Relative humidity sensor Integrated relative humidity monitoring
Atmospheric pressure sensor Integrated pressure monitoring
Tilt sensor Instrument inclination monitoring
Diagnostic information Sensor measurements and diagnostic status available through supported communication functions
INSTALLATION AND MAINTENANCE
Installation method Mast mounting
Compatible mast diameter Ø40…60 mm
Typical installation height 0.5…1.5 m above ground
Leveling Integrated bubble level
Mounting hardware Three M6×35 Allen screws
Maintenance Periodic cleaning of collector inlet filter
Installation location Open area, away from obstructions and excessive wind turbulence
MODEL CONFIGURATIONS
Product family RTD series
Model series RTD04
Collecting area code 04 = 400 cm²
Resolution code 1 0.1 mm/tip
Resolution code 2 0.2 mm/tip
Resolution code 5 0.5 mm/tip
Output code 0 Voltage-free NC contact
Output code F RS485, SDI-12 and MOSFET Open Drain
Output code D RS485 and 4…20 mA
Output code V RS485 and 0…10 V
Heating code 0 Without heating
Heating code R With heating

Drawing

RTD04 Latest Posting

Downloads

RTD04 Family Datasheet DownloadRTD04 Family Datasheet
RTD04 Family User Manual DownloadRTD04 Family User Manual
RTD04 Family CE Declaration of Conformity DownloadRTD04 Family CE Declaration of Conformity