WETEC

ECD

T80 Universal Transmitter


Universal single- or dual-channel transmitter for continuous industrial process monitoring with ECD S80 Intelligent Sensors.

  • Supports pH, ORP, pION, dissolved oxygen, turbidity, conductivity, resistivity and other supported measurement parameters

  • Automatic sensor recognition and configuration

  • LCD display with numerical and graphical readings

  • 4–20 mA output, with Modbus RTU depending on configuration

  • Optional HART® communication and alarm relays

  • Weatherproof NEMA 4X polycarbonate enclosure

Quantity
1

Overview

The ECD T80 Universal Transmitter is a single- or dual-channel instrument designed for continuous measurement of pH, ORP, pION, dissolved oxygen, turbidity, conductivity, resistivity and other supported parameters in industrial environments. It communicates digitally with ECD S80 Intelligent Sensors, automatically configuring its menus and display according to the connected sensor. The sensors are factory calibrated and equipped with onboard memory for sensor identification and calibration data.

The transmitter features a graphical LCD with numerical readings, trend lines, bar graphs and gauge displays. It provides 4–20 mA output, with Modbus RTU communication available on line-powered versions. HART® communication and alarm relays are optional. Housed in a weatherproof NEMA 4X polycarbonate enclosure, the T80 is available in loop-powered (single-channel only), 24 VDC and 100–240 VAC versions, with multiple mounting configurations.

Typical Applications

  • Continuous industrial process monitoring

  • Monitoring of pH, ORP, specific ions and dissolved oxygen

  • Measurement of turbidity, conductivity and resistivity

  • Signal integration with industrial control and monitoring systems

  • Process alarm and fault monitoring using optional alarm relays

Key Features

  • Single- or dual-channel transmitter configuration

  • Supports pH, ORP, pION, dissolved oxygen, turbidity, conductivity, resistivity and other supported measurement parameters

  • Automatic sensor recognition and configuration with ECD S80 Intelligent Sensors

  • Compatibility with factory-calibrated S80 sensors featuring onboard data storage

  • 128 × 64 pixel graphical LCD with numerical readings, trend lines, bar graphs and gauge displays

  • Intuitive menu structure with membrane switch buttons

  • 4–20 mA output, with Modbus RTU communication on line-powered versions

  • Optional HART® communication

  • Optional three SPDT alarm relays on line-powered versions

  • Loop-powered (single-channel only), 24 VDC or 100–240 VAC power supply options

  • Weatherproof NEMA 4X polycarbonate enclosure

  • Ambient operating temperature range of −20…+70 °C

  • Multiple mounting configurations

Benefits

  • Supports multiple measurement parameters, reducing the need to maintain separate transmitter types

  • Automatic sensor recognition simplifies instrument configuration

  • Factory-calibrated S80 sensors enable immediate use upon connection

  • Numerical and graphical displays facilitate measurement interpretation

  • Intuitive menu navigation simplifies operation and parameter adjustment

  • Flexible output and communication options facilitate integration with industrial control systems

  • Weatherproof NEMA 4X enclosure provides environmental protection

  • Multiple mounting options accommodate different installation requirements

Specifications

General

Model

T80

Instrument type

Universal transmitter

Channel configuration

Single or dual channel

Measurement operation

Continuous measurement

Sensor compatibility

ECD S80 Intelligent Sensors

Input protocol

Digital

Sensor configuration

Automatic sensor recognition and configuration

Analogue input

Optional analogue-to-digital input board for mV sensors on line-powered versions

 

 

Measurement Ranges

pH

−1.00…15.00 pH

ORP

−1500…+1500 mV

pION

0.1…999.9, auto-ranging (ppb, ppm, parts per thousand)

Dissolved oxygen

0.1…999.9, auto-ranging (ppb, ppm, % SAT, mg/L)

Resistivity

0.1…50 MΩ

Turbidity

0.0…9999 NTU, auto-ranging (NTU, FNU, mg/L, ppm, % solids)

Total suspended solids (TSS)

0…150,000 ppm

 

 

Measurement Accuracy

ORP

±1%

pION

±1–2% (specific to ion type)

Dissolved oxygen

±2% of calibrated range

Conductivity

±1% of calibrated range

Resistivity

±2% of calibrated range

Turbidity

±2% of calibrated range

Temperature

±0.3 °C

Total suspended solids (TSS)

±2% of calibrated range

 

 

Display and User Interface

Display type

Graphical LCD

Display resolution

128 × 64 pixels

Display dimensions

2.75 × 1.5 inches

Loop-powered display

Black lettering on grey background

24 VDC and 100–240 VAC powered display

Blue lettering on white background with LED backlight

Display modes

Single-channel and dual-channel display

Display screens

Data screen, millivolt screen and graphical display screen

Graphical display styles

Trend line, bar graph and gauge

Menu navigation

Membrane switch buttons

 

 

Calibration

Sensor calibration

Factory-calibrated S80 Intelligent Sensors

Calibration functions

Auto calibration, standardisation, two-point calibration, single-point calibration and manual calibration

Manual calibration

Entry of previously determined offset and slope values

Calibration data storage

S80 sensor memory

 

 

Configuration Functions

Hold function

Available

Display adjustment

Backlight and contrast adjustment

Instrument identification

Labels and tags

Security

Password protection

Reset function

Factory default reset

Simulation function

Input and output signal simulation

 

 

Power Supply

Loop-powered version (Code −0)

24 VDC, single channel only

Loop power supply range

18…36 VDC

Loop power requirement

35 mW minimum

Maximum loop load

600 Ω

DC-powered version (Code −1)

24 VDC

DC power supply range

18…36 VDC

DC power requirement

250 mW minimum

AC-powered version (Code −2)

100…240 VAC, 50/60 Hz

AC power consumption

4 W

 

 

Outputs and Communication

Analogue output

4…20 mA

Line-powered analogue output configuration

One output per channel

Digital communication

Modbus RTU on line-powered versions

HART® communication

Optional

Fault condition output

3.5 mA, 22 mA or none

 

 

Alarm Relays (Optional)

Availability

Line-powered versions

Number of relays

3

Relay type

SPDT, Form 1C

Maximum resistive current

3 A

Voltage rating

250 VAC

Relay functions

Alarm (setpoint), timer-activated or fault relays

Setpoint alarm configuration

User-configurable high/low alarms

Fault monitoring

T80 self-diagnostics with fault alarms

 

 

Environmental Conditions

Ambient operating temperature

−20…+70 °C

Storage temperature

−30…+85 °C

Relative humidity

0…90%, non-condensing

 

 

Mechanical

Enclosure material

Polycarbonate

Enclosure protection

NEMA 4X, weatherproof

Enclosure format

½ DIN

Dimensions (L × W × D)

14.4 × 14.4 × 9.0 cm (5.7 × 5.7 × 3.5 inches)

 

 

Mounting Configurations

Universal mounting bracket

Standard

Panel mounting

Panel mounting hardware

Handrail mounting

Handrail mounting plate with 2-inch hardware

Pole mounting

SSR polyester sun shield with 2-inch mounting hardware

Rail mounting

SSR polyester sun shield with 2-inch mounting hardware

 

 

Shipping

Shipping dimensions

20.5 × 20.5 × 12.7 cm

Shipping weight

1.6 lbs (0.75 kg)

Drawing

T80 Universal Transmitter Drawing

Downloads

T80 - Universal Transmitter DownloadT80 - Universal Transmitter