ECD
CA6 Copper Analyzer
Automated online colorimetric analyzer for copper measurement in water using the bathocuproine method.
Measuring ranges: 0.05–1 mg/L (26 mm cell), 0.1–3 mg/L (16 mm cell), up to 150 mg/L with internal dilution
Programmable analysis frequency with an 8–10 minute analysis cycle
Automatic calibration, validation and cleaning
Low reagent consumption and color touchscreen interface
Two 4–20 mA outputs and Modbus RTU RS485 communication
Dual-compartment enclosure with IP54 protection
Overview
The CA-6 Copper Analyzer is an automated online colorimetric analyzer designed to measure copper concentrations in water using the bathocuproine method. It uses an LED light source and a heated reaction cell to perform differential photometric absorbance measurements at 470 nm. The analyzer offers measuring ranges of 0.05–1 mg/L with a 26 mm cell and 0.1–3 mg/L with a 16 mm cell, extending up to 150 mg/L with internal dilution.
The analyzer features programmable analysis frequency, automatic calibration, validation and cleaning, with an analysis cycle of 8–10 minutes. Its IP54-rated dual-compartment enclosure separates the electrical and liquid components, while the color touchscreen provides access to measured values, operating status and configuration settings. It also includes an integrated data logger with USB download, two 4–20 mA outputs and Modbus RTU RS485 communication.
Typical Applications
Copper monitoring in wastewater
Copper measurement in process water
Copper monitoring in industrial sewage treatment plants
Copper measurement in ultrapure water treatment systems
Key Features
Automated online sequential sampling and colorimetric analysis using the bathocuproine method
LED light source and heated reaction cell with measurement at 470 nm
Measuring ranges of 0.05–1 mg/L (26 mm cell) and 0.1–3 mg/L (16 mm cell), extending up to 150 mg/L with internal dilution
Programmable analysis frequency with an 8–10 minute analysis cycle
Automatic calibration, validation and cleaning
Low reagent consumption
Color touchscreen interface with multilingual menu
Integrated data logger with USB download
Two 4–20 mA outputs and Modbus RTU RS485 communication
Four programmable SPDT relays, with loss of sample and low reagent alarm functions
Multiple sample stream configurations, supporting up to four streams with an external sequencer
Dual-compartment enclosure separating electrical and liquid components
Epoxy powder-coated cold-rolled steel cabinet with IP54 ingress protection
Standard 100–240 VAC, 50/60 Hz power supply with optional 24 VDC
Benefits
Automated online analysis reduces the need for manual copper measurements
Differential colorimetric measurement minimizes interference from sample color and turbidity
Low reagent consumption and adjustable analysis frequency help reduce operating costs
Automatic calibration, validation and cleaning reduce downtime and operator intervention
Wide measuring range accommodates different copper concentrations
User-friendly touchscreen simplifies operation and configuration
Integrated data logging enables convenient measurement recording and retrieval
Analog and digital outputs facilitate integration with monitoring and control systems
Separate electrical and liquid compartments keep electronic components isolated from the wet section
Factory-tested system simplifies installation and commissioning
Specifications
Measurement | |
|---|---|
Measured parameter | Cu⁺ / Cu²⁺ |
Measurement units | ppb, ppm, mg/L |
Measuring principle | Differential photometric absorbance |
Analytical method | Bathocuproine method |
Measurement wavelength | 470 nm |
Light source | LED |
Measuring range (26 mm cell) | 0.05–1 mg/L |
Measuring range (16 mm cell) | 0.1–3 mg/L |
Extended measuring range | Up to 150 mg/L with internal dilution |
Reproducibility (26 mm cell) | ±20 ppb or ±5%, whichever is greater |
Reproducibility (16 mm cell) | ±50 ppb or ±5%, whichever is greater |
Analysis and Operation | |
|---|---|
Analysis frequency | Freely programmable, batch near-continuous analysis |
Analysis cycle time | 8–10 minutes, including conditioning before analysis and rinsing after measurement |
Reaction cell | Heated colorimetric reaction cell |
Calibration, validation and cleaning | Automatic, with freely selectable intervals |
Sample Requirements | |
|---|---|
Sample supply | Pressure-free from overflow vessel |
Sample temperature | 5–50 °C (41–122 °F) |
Sample flow rate | 80–500 mL/min |
Sample connection | 6 mm (¼ in.) |
Drain Requirements | |
|---|---|
Drain condition | Pressure-free, atmospheric drain |
Drain connection | 12 mm (½ in.) |
Sample Stream Configuration | |
|---|---|
Number of sample streams | 1 or 2; 3 or 4 with external sequencer |
Dual-stream configuration | Integrated switching valve |
Reagent Consumption | |
|---|---|
Reagent consumption (16 mm cell) | R1: 1 L; R2: 1 L; R3: 2 L |
Reagent consumption (26 mm cell) | R1: 2 L; R2: 2 L; R3: 4 L |
Reference operating conditions | 30 days with a 15-minute analysis frequency |
User Interface and Data Management | |
|---|---|
User interface | Graphic color touchscreen |
Display information | Measured values and status information |
Language support | Multiple languages |
Data logger | Integrated, with USB download |
Outputs, Inputs and Alarms | |
|---|---|
Analog outputs | 2 × 4–20 mA for measured data |
Digital communication | Modbus RTU RS485 |
Alarm relays | 4 programmable potential-free SPDT relays |
Alarm functions | Loss of sample and low reagent |
Digital input | Remote start/stop |
Power Supply | |
|---|---|
Standard power supply | 100–240 VAC, 50/60 Hz |
Optional power supply | 24 VDC |
Power consumption | Maximum 80 VA |
Environmental Conditions | |
|---|---|
Operating temperature | 5–45 °C (41–113 °F) |
Operating humidity | 10–90%, non-condensing |
Operating environment | Indoor use; outdoor installation requires a protective cabinet or shelter (not included) |
Physical | |
|---|---|
Dimensions (H × W × D) | 606 × 380 × 209 mm / 23.6 × 15.0 × 8.2 in. |
Weight | Approximately 20 kg (44 lbs) |
Cabinet material | Cold-rolled steel |
Cabinet finish | Epoxy powder-coated |
Enclosure design | Separate electrical and liquid compartments |
Access doors | Two lockable doors |
Ingress protection | IP54 |
Installation | |
|---|---|
Standard installation | Wall mount |
Optional installation | Bench-top support or panel mount |
Drawing

Downloads
| CA6 - Copper Analyzer Brochure | DownloadCA6 - Copper Analyzer Brochure |
|---|
Related Products

ECD
DCA-23 Seawater Dechlorination Analyzer
The DCA-23 monitors seawater chlorination and dechlorination from 0.00–2.00 ppm chlorine equivalent, featuring reagent-free measurement, flow-independent…
Learn More
ECD
DC80 Dechlorination Analyzer
The DC80 Dechlorination Analyzer uses a zero-shift measurement strategy, automatic flow control and pH compensation to monitor very low total chlorine levels…
Learn More
ECD
CD80 Chlorine Dioxide Analyzer
The CD80 is a reagentless, panel-mounted analyzer for continuous chlorine dioxide (ClO₂) monitoring from 0.05 to 20 ppm, featuring automatic flow control, a…
Learn More
ECD
TC80 Total Chlorine Analyzer
The TC80 is a reagentless, panel-mounted analyzer for total chlorine monitoring in water, featuring amperometric sensing, automatic pH compensation, automatic…
Learn More