ECD
CA6 Cyanide Analyzer
Online colorimetric analyzer for automatic measurement of free cyanide in water.
Automatic calibration, validation and cleaning
Programmable analysis frequency and low reagent consumption
Colour touchscreen interface with integrated data logger
Two 4–20 mA outputs and Modbus RTU RS485 communication
Dual-compartment enclosure with IP54 protection
Overview
The ECD CA-6 Cyanide Analyzer is a compact online colorimetric instrument designed for automatic measurement of free cyanide in water. It uses differential photometric absorbance and programmable sequential sampling for monitoring drinking water, surface water, industrial wastewater and municipal wastewater.
The analyzer incorporates automatic calibration, validation and cleaning functions, a colour touchscreen interface and an integrated data logger with USB download capability. It provides two 4–20 mA outputs, Modbus RTU RS485 communication and four programmable alarm relays. Its IP54-rated dual-compartment enclosure separates the electrical and liquid-handling components, while low reagent consumption helps minimise operating costs.
Typical Applications
Free cyanide monitoring in drinking water
Free cyanide monitoring in industrial wastewater
Free cyanide monitoring in municipal wastewater
Free cyanide monitoring in surface water
Key Features
Online colorimetric measurement of free cyanide using differential photometric absorbance
Programmable sequential sampling and analysis frequency
Automatic calibration, validation and cleaning
Colour touchscreen interface with multilingual menu
Integrated data logger with USB download capability
Low reagent consumption
Two 4–20 mA outputs and Modbus RTU RS485 communication
Four programmable SPDT alarm relays
Remote start and stop capability
Multiple sample stream configurations
IP54-rated dual-compartment enclosure separating electrical and liquid-handling components
Factory tested and ready for installation
Benefits
Automated free cyanide monitoring reduces manual analysis
Automatic calibration, validation and cleaning minimise downtime and maintenance requirements
Low reagent consumption helps reduce operating costs
User-friendly touchscreen simplifies operation and configuration
Separate compartments keep electrical components isolated from liquid-handling components
Communication outputs facilitate integration with monitoring and control systems
Multiple sample stream options provide flexibility in monitoring different sampling points
Factory-tested design simplifies installation
Specifications
Measurement |
|
|---|---|
Measured parameter |
Free cyanide (CN⁻) |
Measurement units |
ppb, ppm, mg/L |
Measuring principle |
Differential photometric absorbance |
Measuring range |
2–100 ppb CN⁻ (26 mm cell); 10–200 ppb CN⁻ (16 mm cell) |
Reproducibility |
±4 ppb or ±5%, whichever is greater (26 mm cell); ±10 ppb or ±5%, whichever is greater (16 mm cell) |
Analysis frequency |
Freely programmable, batch near-continuous analysis |
Cycle time |
15–18 minutes, including conditioning before analysis and rinsing after measurement |
Reaction cell |
Heated colorimetric reaction cell |
Sample Requirements |
|
|---|---|
Sample pressure |
Pressure-free from overflow vessel |
Sample temperature |
+5…+50 °C (41…122 °F) |
Sample flow rate |
80–500 mL/min |
Sample connection |
6 mm (¼ in.) |
Drain Requirements |
|
|---|---|
Drain type |
Pressure-free, atmospheric drain |
Drain connection |
12 mm (½ in.) |
Sample Stream Configuration |
|
|---|---|
Number of sample streams |
Single stream; two streams with integrated switching valve; three or four streams with external sequencer |
User Interface and Data Management |
|
|---|---|
User interface |
Colour graphic touchscreen |
Display information |
Measured values and status information |
Menu languages |
Multiple languages |
Data logging |
Integrated data logger with USB download |
Automatic Functions |
|
|---|---|
Automatic functions |
Calibration, validation and cleaning as standard |
Function intervals |
Freely selectable calibration, validation and cleaning intervals |
Outputs, Communication and Alarms |
|
|---|---|
Analogue outputs |
2 × 4–20 mA for measured data |
Digital communication |
Modbus RTU RS485 |
Alarm relays |
4 × programmable SPDT potential-free relays |
System alarms |
Loss of sample and low reagent |
Digital input |
Remote start/stop |
Power Supply |
|
|---|---|
Power supply |
100–240 VAC, 50/60 Hz (standard); 24 VDC (optional) |
Power consumption |
Maximum 80 VA |
Environmental Conditions |
|
|---|---|
Operating temperature |
+5…+45 °C (41…113 °F) |
Relative humidity |
10–90%, non-condensing |
Operating environment |
Indoor use; outdoor installation requires a protective cabinet or shelter (not included) |
Physical |
|
|---|---|
Dimensions (H × W × D) |
606 × 380 × 209 mm* |
Weight |
Approx. 20 kg (44 lbs) |
Cabinet material |
Cold-rolled steel |
Cabinet coating |
Epoxy powder coating |
Enclosure design |
Separate electrical and liquid-handling compartments with two lockable doors |
Ingress protection |
IP54 |
Installation |
Wall mount (standard); benchtop support or panel mount (optional) |
Drawing

Downloads
| CA6 - Cyanide Analyzer Brochure | DownloadCA6 - Cyanide Analyzer Brochure |
|---|
Related Products

ECD
DCA-23 Seawater Dechlorination Analyzer
The DCA-23 monitors seawater chlorination and dechlorination from 0.00–2.00 ppm chlorine equivalent, featuring reagent-free measurement, flow-independent…
Learn More
ECD
DC80 Dechlorination Analyzer
The DC80 Dechlorination Analyzer uses a zero-shift measurement strategy, automatic flow control and pH compensation to monitor very low total chlorine levels…
Learn More
ECD
CD80 Chlorine Dioxide Analyzer
The CD80 is a reagentless, panel-mounted analyzer for continuous chlorine dioxide (ClO₂) monitoring from 0.05 to 20 ppm, featuring automatic flow control, a…
Learn More
ECD
TC80 Total Chlorine Analyzer
The TC80 is a reagentless, panel-mounted analyzer for total chlorine monitoring in water, featuring amperometric sensing, automatic pH compensation, automatic…
Learn More