Senseca
CONDIX4213 Digital Conductivity Transmitter
Digital conductivity converter with a 4-electrode measuring cell for liquid monitoring.
Conductivity measuring range of 0–500 mS/cm
Cell constant of 0.5 cm⁻¹
Selectable temperature compensation
RS485 interface with Modbus RTU protocol
PVC-U process material and IP67 protection
Overview
The Senseca CONDIX4213 is a digital conductivity converter designed to measure the specific conductivity of liquids. It uses a 4-electrode measuring cell with a nominal cell constant of 0.5 cm⁻¹ and a conductivity measuring range of 0–500 mS/cm. Its measuring principle reduces the influence of contamination, polarization effects and wire resistance, making it suitable for landfill leachate, seawater and blackwater treatment on ships.
The converter features integrated temperature measurement with selectable temperature compensation functions and an RS485 interface using the Modbus RTU protocol for transmitting measurement values, identification data and diagnostic information. Device parameters can be configured via the interface or SENSware software. It incorporates PVC-U process material, a PVC fitting with cap nut, IP67 protection and LED indicators for power supply, bus communication and addressing status.
Typical Applications
Conductivity monitoring in landfill leachate treatment
Seawater conductivity measurement
Blackwater treatment on ships
Digital process monitoring through PLC and SCADA systems
Key Features
4-electrode conductivity measuring principle
Conductivity measuring range of 0–500 mS/cm
Nominal cell constant of 0.5 cm⁻¹
Integrated temperature measurement with selectable temperature compensation
Reduced influence of contamination, polarization effects and wire resistance
RS485 half-duplex interface with Modbus RTU protocol
Configurable device parameters via the interface, SENSware software or MULTICON-H
PVC fitting with cap nut for installation with standard PVC-U fittings
8-pin round connector with nickel-plated brass construction
LED indicators for power supply, bus communication and addressing status
Supply voltage of 4.7–28 V DC
IP67 protection rating
Benefits
Conductivity and temperature measurements from a single device
Wide measuring range accommodates liquids with high conductivity
Reliable measurement in contaminated media with reduced influence of polarization and wire resistance
Flexible temperature compensation to suit different liquid media
Easy integration into PLC and SCADA systems via digital communication
Convenient configuration of device parameters to suit application requirements
Simplified installation using standard PVC-U fittings
Protection against dust and water ingress with IP67-rated housing
Specifications
Conductivity Measurement | |
|---|---|
Measuring principle | 4-electrode conductive measurement |
Measuring range | 0–500 mS/cm |
Nominal cell constant | 0.5 cm⁻¹ (exact value indicated on the type plate) |
Basic accuracy | 1% of measured value (>2% of measured value for readings below 20 µS/cm) |
Measurement units | S/m, mS/cm, µS/cm |
Temperature Measurement | |
|---|---|
Measuring element | Integrated Pt1000 |
Measuring range | −50 to +200 °C |
Basic accuracy | 0.2 K |
Linearisation error | 0.1% |
Measurement units | °C, °F |
Temperature Compensation | |
|---|---|
Reference temperature | 25 °C |
Without compensation | Selectable |
Linear compensation | Linear temperature coefficient |
Natural water | EN 27888 (0–36 °C) |
Diluted NaCl solution | IEC 746 Part 3 (0–140 °C) |
Ultra-pure water | ASTM D1125 (0–100 °C) |
Acidic pure water | ASTM D5391 (0–100 °C) |
Alkaline pure water | ASTM D5391 (0–100 °C) |
Power Supply | |
|---|---|
Supply voltage | 4.7–28 V DC |
Current consumption | Max. 60 mA |
Digital Communication | |
|---|---|
Interface | RS485, 2-wire, half-duplex |
Communication protocol | Modbus RTU |
Baud rates | 1200, 2400, 4800, 9600, 19200 baud |
Electrical Connection | |
|---|---|
Connector type | 8-pin M12 × 1 round connector plug |
Connector material | Nickel-plated brass |
Process Connection | |
|---|---|
Process connection | PVC fitting with cap nut, compatible with standard PVC-U fittings |
Maximum tightening torque | 3 Nm |
Process pressure | −1 to 16 bar (subject to pressure–temperature limits) |
Materials | |
|---|---|
Wetted materials | PVC-U, casting resin, graphite (electrodes) |
Viewing window | Acrylic glass (PMMA) |
Operating and Environmental Conditions | |
|---|---|
Process temperature | 0 to +60 °C |
Ambient/storage temperature | −10 to +60 °C |
Condensation | Not permitted |
Protection rating | IP67 |
Configuration and Addressing | |
|---|---|
Parameterisation methods | Modbus RTU interface, SENSware software or MULTICON-H |
Addressing | Field-attachable female connector or junction box |
Optical Signaling | |
|---|---|
Number of status LEDs | 5 |
Supply voltage indicator | Green LED |
Addressing indicators | Three yellow LEDs (Adr. 0, 1 and 2) |
Bus communication indicator | Red/green LED |
Physical | |
|---|---|
Total weight | Approx. 160 g |
Installation Dimensions, D (mm) | Installation Dimensions, H (mm) | Installation Dimensions, A (mm) | Installation Dimensions, E (mm) |
|---|---|---|---|
20 | 135 | 78 | 16 |
25 | 135 | 78 | 19 |
32 | 135 | 78 | 22 |
40 | 140 | 98 | 26 |
50 | 155 | 118 | 31 |
65 | 169 | 144 | 39 |
Conformity and Standards | |
|---|---|
Conformity | CE |
EMC Directive | 2014/30/EU |
RoHS Directive | 2011/65/EU |
EMC standard | EN IEC 61326-1:2013 |
RoHS standard | EN IEC 63000:2018 |
Drawing

Downloads
| Condix4213 Family Datasheet | DownloadCondix4213 Family Datasheet |
|---|---|
| CONDIX4213 Mod Family User Manual | DownloadCONDIX4213 Mod Family User Manual |
| Modbus-Sensors Family Interface Description | DownloadModbus-Sensors Family Interface Description |
| CONDIX4213 Family CE Declaration of Conformity | DownloadCONDIX4213 Family CE Declaration of Conformity |
Related Products
Senseca
UNICON-LF-01/02/03 Conductivity Converter
Conductivity converter for liquid purity and concentration monitoring.
Learn More
Senseca
LF4003 Conductivity Cell for Wells and Open Water Systems
4-electrode immersion conductivity cell for wells and open systems up to 100 m depth.
Learn More
Senseca
ORP211 Combined Redox Electrode for Polluted Wastewater Media
Combined Redox electrode for heavily polluted media in wastewater and process chemistry.
Learn MoreSenseca
UNICON-PH-01/02 pH and ORP Converter
pH and ORP converter for process monitoring with programmable ranges of −1.00 to +15.00 pH or ±1500 mV, Pt100/Pt1000 temperature compensation, 4–20 mA output…
Learn More