WETEC

Senseca

ORP211 Combined Redox Electrode for Polluted Wastewater Media

WaterProcess & Automation

Combined Redox electrode for heavily polluted media in wastewater treatment and process chemistry.

  • Measurement range ±2000 mV

  • Operating temperature −5…+100 °C and maximum pressure of 5 bar

  • Double hole diaphragm and gel electrolyte

  • Double chamber reference system for extended electrode lifetime

  • Minimum media conductivity of 150 µS/cm

  • 120 mm installation length, PG13.5 process connection and S8 electrical connection

Quantity
1

Overview

The Senseca ORP211 is a combined Redox electrode designed for oxidation-reduction potential (ORP) measurement in contaminated to heavily contaminated media, particularly in wastewater treatment and process chemistry. It incorporates a platinum measuring electrode, an Ag/AgCl reference system, gel electrolyte and an electrolyte bridge. Its double hole diaphragm provides direct media contact, minimises diaphragm interference voltage and resists clogging, while the double chamber reference system extends electrode lifetime.

The electrode covers a measurement range of ±2000 mV and operates at temperatures from −5 to +100 °C, with a maximum pressure of 5 bar and a minimum media conductivity of 150 µS/cm. It features a 120 mm installation length, 12 mm diameter, PG13.5 process connection and S8 electrical connection for process integration.

Typical Applications

  • Redox potential (ORP) monitoring in wastewater treatment

  • Redox measurement in contaminated to heavily contaminated media in process chemistry

Key Features

  • Combined potentiometric Redox electrode with platinum measuring element

  • Measurement range of ±2000 mV

  • Operating temperature range of −5…+100 °C

  • Maximum operating pressure of 5 bar

  • Double chamber Ag/AgCl reference system

  • Two-hole diaphragm with direct media contact

  • 3 mol/L KCl gel electrolyte and electrolyte bridge

  • Minimum media conductivity of 150 µS/cm

  • 120 mm installation length and 12 mm diameter

  • PG13.5 process connection

  • S8 electrical connection

  • Installation position of 10…170° (upright)

Benefits

  • Extended electrode lifetime through a double chamber reference system with an extended diffusion range

  • Resistance to diaphragm clogging due to large-diameter openings

  • Minimal diaphragm interference voltage through direct media contact

Specifications

Measurement

Sensor type

Combined Redox electrode

Measuring principle

Potentiometric

Measurement range

±2000 mV

Minimum conductivity of media

150 µS/cm

Application scope

Wastewater treatment and process chemistry

 

 

Operating Conditions

Working temperature

−5…+100 °C

Maximum pressure

5 bar

 

 

Electrode and Reference System

Measuring electrode

Platinum

Reference system

Ag/AgCl

Reference system design

Double chamber with extended diffusion range

Reference electrolyte

3 mol/L KCl gel

Diaphragm

2 × hole diaphragm

Electrolyte bridge

Included

 

 

Mechanical and Installation

Diameter

12 mm

Installation length

120 mm

Process connection

PG13.5

Installation position

10…170° (upright)

 

 

Electrical Connection

Electrical connection

S8 plug

 

 

Storage Conditions

Storage temperature

−5…+30 °C

Storage solution

3 mol/L KCl solution

Storage period

Storage exceeding 1 year is not recommended

 

 

Standards and Compliance

EU directive

2011/65/EU (RoHS)

Harmonised standard

EN IEC 63000:2018

Downloads

ORP211 Family Datasheet DownloadORP211 Family Datasheet
Ph-Redox-Electrodes Family Operating Instructions DownloadPh-Redox-Electrodes Family Operating Instructions
ORP211 Family CE Declaration of Conformity DownloadORP211 Family CE Declaration of Conformity