Senseca
ORP211 Combined Redox Electrode for Polluted Wastewater Media
Combined Redox electrode for heavily polluted media in wastewater treatment and process chemistry.
Measurement range ±2000 mV
Operating temperature −5…+100 °C and maximum pressure of 5 bar
Double hole diaphragm and gel electrolyte
Double chamber reference system for extended electrode lifetime
Minimum media conductivity of 150 µS/cm
120 mm installation length, PG13.5 process connection and S8 electrical connection
Overview
The Senseca ORP211 is a combined Redox electrode designed for oxidation-reduction potential (ORP) measurement in contaminated to heavily contaminated media, particularly in wastewater treatment and process chemistry. It incorporates a platinum measuring electrode, an Ag/AgCl reference system, gel electrolyte and an electrolyte bridge. Its double hole diaphragm provides direct media contact, minimises diaphragm interference voltage and resists clogging, while the double chamber reference system extends electrode lifetime.
The electrode covers a measurement range of ±2000 mV and operates at temperatures from −5 to +100 °C, with a maximum pressure of 5 bar and a minimum media conductivity of 150 µS/cm. It features a 120 mm installation length, 12 mm diameter, PG13.5 process connection and S8 electrical connection for process integration.
Typical Applications
Redox potential (ORP) monitoring in wastewater treatment
Redox measurement in contaminated to heavily contaminated media in process chemistry
Key Features
Combined potentiometric Redox electrode with platinum measuring element
Measurement range of ±2000 mV
Operating temperature range of −5…+100 °C
Maximum operating pressure of 5 bar
Double chamber Ag/AgCl reference system
Two-hole diaphragm with direct media contact
3 mol/L KCl gel electrolyte and electrolyte bridge
Minimum media conductivity of 150 µS/cm
120 mm installation length and 12 mm diameter
PG13.5 process connection
S8 electrical connection
Installation position of 10…170° (upright)
Benefits
Extended electrode lifetime through a double chamber reference system with an extended diffusion range
Resistance to diaphragm clogging due to large-diameter openings
Minimal diaphragm interference voltage through direct media contact
Specifications
Measurement | |
|---|---|
Sensor type | Combined Redox electrode |
Measuring principle | Potentiometric |
Measurement range | ±2000 mV |
Minimum conductivity of media | 150 µS/cm |
Application scope | Wastewater treatment and process chemistry |
Operating Conditions | |
|---|---|
Working temperature | −5…+100 °C |
Maximum pressure | 5 bar |
Electrode and Reference System | |
|---|---|
Measuring electrode | Platinum |
Reference system | Ag/AgCl |
Reference system design | Double chamber with extended diffusion range |
Reference electrolyte | 3 mol/L KCl gel |
Diaphragm | 2 × hole diaphragm |
Electrolyte bridge | Included |
Mechanical and Installation | |
|---|---|
Diameter | 12 mm |
Installation length | 120 mm |
Process connection | PG13.5 |
Installation position | 10…170° (upright) |
Electrical Connection | |
|---|---|
Electrical connection | S8 plug |
Storage Conditions | |
|---|---|
Storage temperature | −5…+30 °C |
Storage solution | 3 mol/L KCl solution |
Storage period | Storage exceeding 1 year is not recommended |
Standards and Compliance | |
|---|---|
EU directive | 2011/65/EU (RoHS) |
Harmonised standard | EN IEC 63000:2018 |
Downloads
| ORP211 Family Datasheet | DownloadORP211 Family Datasheet |
|---|---|
| Ph-Redox-Electrodes Family Operating Instructions | DownloadPh-Redox-Electrodes Family Operating Instructions |
| ORP211 Family CE Declaration of Conformity | DownloadORP211 Family CE Declaration of Conformity |
Related Products
Senseca
UNICON-LF-01/02/03 Conductivity Converter
Conductivity converter for liquid purity and concentration monitoring.
Learn More
Senseca
LF4003 Conductivity Cell for Wells and Open Water Systems
4-electrode immersion conductivity cell for wells and open systems up to 100 m depth.
Learn MoreSenseca
UNICON-PH-01/02 pH and ORP Converter
pH and ORP converter for process monitoring with programmable ranges of −1.00 to +15.00 pH or ±1500 mV, Pt100/Pt1000 temperature compensation, 4–20 mA output…
Learn More
Senseca
CONDIX4213 Digital Conductivity Transmitter
Digital conductivity converter for water treatment and industrial liquid monitoring.
Learn More