EFK2 Flow Switch for Liquid Media Monitoring
Calorimetric flow switch for liquid media monitoring
Monitors the flow velocity of liquids with a calorimetric principle and no moving parts in the medium, for water at 2...150 cm/s or 3...300 cm/s, with 1...3 s response time in water.
Switching point set directly by potentiometer, with a red/green LED showing whether the flow is below or above the limit value.
Galvanically isolated relay contact or push-pull transistor output, M12x1 plug, IP65, with G ¼ A...G ½ A screw-in or Ø12 mm push-in sensors.
Overview
The Senseca EFK2 is a compact flow switch for monitoring the flow velocity of liquid media. It uses a calorimetric measuring principle with no moving parts in the monitored medium, and measures water flow at 2...150 cm/s or 3...300 cm/s.
The switching point is set directly with a potentiometer, and a red/green LED shows whether the flow is below or above the limit value. The output is either a galvanically isolated relay contact or a push-pull transistor output.
Typical applications
Flow monitoring of water and other liquid media
Tight pipe layouts that need a very small installation width
Installation points that need free orientation and reading direction (gooseneck option)
Flow monitoring with relay or push-pull switching output
Key Features
Very small installation width, therefore very narrow pipework is possible
No moving parts in the medium being monitored
Installation largely independent of nominal width
Calorimetric measuring principle, water ranges 2...150 cm/s or 3...300 cm/s
Switching point set by potentiometer
Red/green LED status display
Galvanically separated relay contact or push-pull transistor output
Screw-in versions G ¼ A...G ½ A or Ø12 mm push-in sensors
M12x1 plug, 4-pole, IP65
Optional gooseneck between sensor and electronics head
Benefits
Fits narrow pipework thanks to the very small installation width
Calorimetric sensing without moving parts in the medium
Easy setup: the switching point is taught with the potentiometer and the LED changes from red to green
Clear status check with the red/green LED
Push-pull outputs configure themselves depending on PNP or NPN wiring
Wetted parts in stainless steel 1.4571, pressure resistance PN 100 bar (optionally PN 200 bar)
Optional gooseneck for the best view of the display in awkward installation locations
Specifications
INPUT |
|
Measuring principle | Calorimetric |
Measuring range | Water 2...150 cm/s or 3...300 cm/s; oil available on request |
Process connection | Screw-in thread G ¼ A...G ½ A; push-in sensor Ø12 mm |
MEASURING ACCURACY |
|
Measurement accuracy | ±10 % of full scale value |
Dynamics | 1...3 seconds in water |
OUTPUTS |
|
Switching output | Galvanically separated relay contact, or push-pull transistor output (resistant to short circuits and reverse polarity protected) |
Output loading | Relay: 2 A / 30 V DC/AC max.; transistor output: 100 mA / 24 V max. |
Display | Red / green LED (red: flow < limit value; green: flow > limit value) |
Adjustment | Potentiometer (set the flow to the limit value and turn until the LED just switches from red to green) |
POWER REQUIREMENT |
|
Supply voltage | 24 V DC / AC ±10 % |
Current consumption | Max. 70 mA |
ENVIRONMENTAL |
|
Media temperature | 0...70 °C |
Ambient temperature | -20...+70 °C |
Temperature gradient | 4 K/s |
Pressure resistance | PN 100 bar, optionally PN 200 bar |
Ingress protection | IP 65 |
MATERIALS |
|
Materials, medium-contact | 1.4571 |
Materials, non-medium-contact | 1.4305 |
MECHANICAL |
|
Connection size 008 / 015 | Connection G ¼ A / G ½ A (male thread) |
Connection size 013 | System fastener Ø13.2 (for insertion into the system T-piece) |
Connection size 012 | Push-in sensor Ø12 with variable insertion depth |
Sensor length, thread versions | 28.0 mm (G ¼ A); 29.6 mm (G ½ A); 45.0 mm (G ½ A, option) |
Sensor for T-piece | For T-piece G ⅜...G ½ (code 031) or G ¾...G 2 (code 037) |
Insertion sensor length | 50 mm; 70 mm; 100 mm; 150 mm; 200 mm |
Electrical connection | For round plug connector M12x1, 4-pole |
Wiring, push-pull output | 1 brown: +; 4 black: output; 3 blue: 0 V (outputs configure themselves depending on PNP or NPN connection) |
Wiring, relay contact (NO / NC) | 1 brown and 3 blue: 24 V DC / AC; 2 white and 4 black: signal (contact) |
Relay contact function | NO: open when there is no flow; NC: closed when there is no flow |
Gooseneck option | Optional gooseneck between the sensor and the electronics head, for free orientation and reading direction |
Installation | Flow must impinge on the marking (X) on the sensor; install where flow conditions are reproducible (sufficient run-in length, no valves, kinks or bends directly ahead of the sensor) |
Weight | Approx. 0.3 kg |
APPROVALS |
|
Conformity | CE |
Drawing

Downloads
| Senseca-EFK2-Datasheet-EN | DownloadSenseca-EFK2-Datasheet-EN |
|---|
Related Products

Senseca
RRI-032 Paddle Wheel Flow Transmitter for DN 32 Pipes
Flow transmitter for liquid flow monitoring in pipes from DN 32, with a measuring range of 0.3.6 m/s and PNP/NPN, NAMUR, 4.20 mA, 0.10 V, frequency or limit…
Learn More
Senseca
FU4SK Flow Transmitter and Switch for Industrial Liquids
Flow transmitter and switch for liquid flow and temperature, measuring 3.300 cm/s and -20.+110 °C, with RS485 Modbus-RTU or IO-Link electronics and a fully…
Learn More
Senseca
OMNIPLUS-RRI-025 Impeller Flow Transmitter DN 25
Impeller flow transmitter for water and low-viscosity liquids, covering 2.100 l/min in DN 25 and PN 16, with LCD, IO-Link, analog output and two configurable…
Learn More
Senseca
OMNIPLUS-F Thermal Flow and Temperature Transmitter
Thermal flow and temperature transmitter for water and other liquids, measuring flow from 2.300 cm/s with a 1.2 inch graphic LCD, IO-Link, analog output and…
Learn More