WETEC

Senseca

FU4SK Flow Transmitter and Switch for Industrial Liquids


Flow transmitter and switch for liquid flow and temperature, measuring 3...300 cm/s and -20...+110 °C, with RS485 Modbus-RTU or IO-Link electronics and a fully welded stainless steel housing.
Quantity
1

Overview

The Senseca FU4SK is a compact flow transmitter and switch for monitoring, control and continuous measurement of flow and temperature in liquids. A wear-free calorimetric sensor covers flow from 3...300 cm/s and process temperatures from -20 °C to +110 °C.

It has a fully welded stainless steel housing (IP69K / IP67) and is available with RS485 Modbus-RTU or IO-Link electronics. A choice of process connections (G½"A or G¼"A) and sensor lengths helps match the device to the installation.

Typical applications

  • Machinery and plant engineering

  • Air-conditioning and refrigeration plant engineering

  • Hydraulic and pneumatic systems

  • Process industry

  • Environmental technology

  • Facility and building automation

Key Features

  • Flow velocities from 3 cm/s to 300 cm/s

  • Wide variety of process connections and sensor lengths

  • Wear-free calorimetric sensor

  • Process temperature range -20 °C to +110 °C

  • High process pressure tightness up to 40 bar

  • Fully welded robust steel enclosure

  • High protection class IP69K / IP67

  • Evaluation electronics with RS485 Modbus-RTU or IO-Link

  • Fast response: flow T90 ≤ 6 s, temperature T90 ≤ 4 s

Benefits

  • One device measures both liquid flow and temperature

  • No wear from the measuring principle (calorimetric sensor)

  • Built for harsh sites: fully welded steel housing, IP69K / IP67, classified shock and vibration resistance

  • Several process connections and sensor lengths to suit the installation

  • Digital adjustment and integration through RS485 Modbus-RTU or IO-Link

  • Options include LABS-free and silicone-free execution, laser-marked TAG, EN10204 3.1 certificate, drinking water suitability certificate and factory presetting

Specifications

INPUT

 

Measuring principle

Calorimetric flow velocity

Measuring range, flow

3...300 cm/s; greatest sensitivity 3...100 cm/s

Process temperature

-20...+110 °C (maximum -30...+120 °C; compensated -20...+85 °C)

Process pressure

≤ 40 bar

 

 

MEASURING ACCURACY

 

Reference conditions

EN/IEC 60770-1; 15...25 °C / 860...1060 kPa / 45...75 % r.h. / ton 240 s / 24 V DC ±0.1 V; measuring medium water, vertical, sensor downside, inner tube diameter 26 mm, upstream pipe 1 m, downstream pipe 0.5 m, alignment ±5°

Resolution measuring input

FSO ≥ 12 bit

Accuracy, flow

≤ ±5 % MEV (5...100 cm/s); ≤ ±10 % MEV (100...175 cm/s); both at -20...+85 °C (MEV = measuring end value)

Accuracy, temperature

≤ ±1.5 K (≥ 20 cm/s)

Reproducibility, flow

≤ 2 cm/s (5...100 cm/s), -20...+85 °C

Reproducibility, temperature

≤ ±0.5 K (≥ 20 cm/s)

Influence of auxiliary power

≤ ±0.1 % MEV / 10 V

Long term drift, flow

≤ ±10 % MV / year (-20...+85 °C)

Temperature deviation, flow

≤ ±0.4 cm/s / K (-20...+85 °C)

Time behavior, flow

T90 ≤ 6 s; ton ≤ 10 s

Time behavior, temperature

T90 ≤ 4 s; ton ≤ 2 s

 

 

OUTPUTS

 

Output type V: interface

RS485, bidirectional / Modbus-RTU / 9600 Baud (4800...38400 Baud)

Output type V: input resistance

112 kΩ

Output type L: interface

IO-Link V1.1 / Com2 (38400 Baud)

Output type L: cycle time

≥ 2.3 ms

Output type L: analog output

0...20 mA or 4...20 mA

Output type L: permitted load

RL ≤ (Us - 8 V) / 22 mA

Output type L: switch output

2x PP (push-pull), switch to +L/-L

Switch output data

Uout ≤ 0.2 V, ≥ Us - 2 V; Iout 0...200 mA (current limited ≤ 450 mA, short circuit protected); trise < 30 µs (RL < 3 kΩ / Iout > 4.5 mA)

Switch cycles

≥ 100,000,000

 

 

POWER REQUIREMENT

 

Supply voltage Us, type V (RS485 Modbus-RTU)

6...35 V DC, polarity protected; residual ripple ≤ 2 Vpp

Supply voltage Us, type L (IO-Link)

9...35 V DC without IO-Link; 18...30 V DC with IO-Link; polarity protected; residual ripple ≤ 2 Vpp

Supply current, type V

≤ 100 mA (no load)

Supply current, type L

≤ 110 mA (no load)

 

 

ENVIRONMENTAL

 

Environmental temperature

-20...+100 °C

Protection level

IP69K / IP67 (EN/IEC 60529)

Climatic classification

4K4H (EN/IEC 60721-3-4)

Shock classification

50 g [11 ms] (EN/IEC 60068-2-27)

Vibration classification

20 g [10...2000 Hz] (EN/IEC 60068-2-6)

EM compatibility

Operation device class B / industrial range (EN/IEC 61326)

Insulation voltage

500 Vac

MTTF

463 years

 

 

MATERIALS

 

Process wetted

Steel 1.4404/316L, steel 1.4571/316Ti, FPM, EPDM

Not process wetted

CrNi-steel, PUR, acrylic copolymer, FPM

Process connection

CrNi-steel

Terminal enclosure

CrNi-steel

Process gaskets

FPM or EPDM

 

 

MECHANICAL

 

Process connection type 0

Thread G½"A, DIN EN ISO 1179-2 E

Process connection type 3

Thread G¼"A, DIN EN ISO 1179-2 E

Sensor length L1, type 0 (G½"A)

30 mm; 49 mm; 79 mm; 119 mm

Sensor length L1, type 3 (G¼"A)

28 mm; 47 mm; 77 mm; 117 mm

Electrical connection

Plug M12x1

Pin assignment, type V

1 BN: L+; 4 BK: B(-); 2 WH: A(+); 3 BU: L-

Pin assignment, type L

1 BN: L+; 4 BK: Out1 (IO-Link); 2 WH: Out2; 3 BU: L-

Tightening torque

≤ 50 Nm

Weight

0.35 kg

 

 

OPTIONS

 

Additional options

-SF LABS-free, silicone-free / paint compatible version; -ML measurement point designation / TAG, laser marking; -MZ material test certificate EN10204 3.1; -WT factory certification, drink water suitability; -KF configuration / preset

 

 

APPROVALS

 

Conformity

CE

Drawing

Senseca-FU4SK-Dimensional-Drawing

Downloads

Senseca-FU4SK-Datasheet-EN DownloadSenseca-FU4SK-Datasheet-EN
Senseca-FU4-User-Manual-EN DownloadSenseca-FU4-User-Manual-EN