WETEC

Senseca

RRI-032 Paddle Wheel Flow Transmitter for DN 32 Pipes


Paddle wheel flow transmitter for pipes from DN 32

  • Insertion transmitter with paddle wheel and union nut, measuring flow velocity from 0.3...6 m/s in liquids.

  • Suitable for retrofitting in existing pipelines with a weld-on nozzle or tapping clamps (accessories).

  • Versions with PNP/NPN, NAMUR, 4...20 mA, 0...10 V, frequency (up to 2 kHz) or limit switch output, PVC housing, IP65 and PN 10.

Quantity
1

Overview

The Senseca RRI-032 is a compact insertion flow transmitter for liquid flow monitoring in pipes from DN 32. It uses a paddle wheel to measure flow velocity from 0.3...6 m/s and is mounted with an insertion probe and union nut.

It suits retrofitting into existing pipelines using a weld-on nozzle or tapping clamps, where a full measuring section is not required. Several output versions are available, with a PVC housing, IP65 protection and a PN 10 pressure rating.

Typical applications

  • Liquid flow monitoring in pipes from DN 32

  • Retrofitting flow measurement into existing pipelines

  • Flow monitoring where a full measuring section is not required

  • Limit switch monitoring of flow

  • Control systems using PNP/NPN, NAMUR, 4...20 mA, 0...10 V or frequency signals

Key Features

  • Simple and affordable flow transmitter for pipe diameters of DN 32 or larger

  • Paddle wheel measuring principle

  • Measuring range 0.3...6 m/s

  • Plastic version (PVC housing)

  • Suitable for retrofitting in existing pipelines with tapping clamps or weld-on nozzles

  • Insertion probe with union nut, tightening torque 30 Nm

  • Output versions: PNP/NPN, NAMUR, 4...20 mA, 0...10 V, frequency or limit switch

  • Frequency output programmable up to 2 kHz (version F)

  • 2 m cable or M12x1 round plug connector, 4-pin

  • IP65 protection and PN 10 pressure resistance

Benefits

  • Easy retrofitting into existing pipelines with a weld-on nozzle or tapping clamps

  • Choice of output to fit the control system

  • Fixed-range and adjustable versions available

  • Reproducibility of ±1 %

  • Seal material options: FKM, EPDM or NBR

  • Short-circuit and reverse polarity protection on most output versions (reverse polarity only on NAMUR)

Specifications

INPUT

 

Measuring principle

Paddle wheel

Nominal widths

DN 32 and larger

Measuring range

0.3...6 m/s

Range options (code 1)

Adjustable in the device, or fixed at 1 m/s, 2 m/s, 4 m/s or 6 m/s

Versions U, I and F

Versions with analog output (U or I) or adjustable frequency output (F) are available with limited measuring ranges (1, 2 and 4 m/s)

Approx. flow rate, DN 32

15...300 l/min (18 m³/h)

Approx. flow rate, DN 40

23...460 l/min (27 m³/h)

Approx. flow rate, DN 50

35...700 l/min (42 m³/h)

Approx. flow rate, DN 65

60...1200 l/min (72 m³/h)

Approx. flow rate, DN 80

90...1800 l/min (108 m³/h)

Approx. flow rate, DN 100

140...2800 l/min (168 m³/h)

Approx. flow rate, DN 125

220...4400 l/min (264 m³/h)

Approx. flow rate, DN 150

315...6300 l/min (378 m³/h)

 

 

MEASURING ACCURACY

 

Reproducibility

±1 %

 

 

OUTPUTS

 

Signal output P / N

PNP / NPN o.C.; output current max. 200 mA; short-circuit proof, reverse polarity protected

Signal output A

NAMUR output circuit (2-wire); reverse polarity protected

Signal output I

Current output 4...20 mA; short-circuit proof, reverse polarity protected

Signal output U

Voltage output 0...10 V; output current max. 20 mA; short-circuit proof, reverse polarity protected

Signal output F

Frequency output programmable up to 2 kHz; push-pull output circuit; output current max. 100 mA; short-circuit proof, reverse polarity protected

Signal output S

Limit switch; push-pull output circuit; output current max. 100 mA; short-circuit proof, reverse polarity protected

Output frequency, versions P, N and A

Approx. 480 Hz at full deflection

 

 

POWER REQUIREMENT

 

Auxiliary voltage, P / N

10...30 V DC

Auxiliary voltage, A (NAMUR)

7...12 V DC

Auxiliary voltage, I / F / S

10...30 V DC

Auxiliary voltage, U

15...30 V DC

Current consumption, P / N

Quiescent current 10 mA

Current consumption, A

Max. 7 mA

Current consumption, I / U / F / S

Quiescent current max. 50 mA

 

 

ENVIRONMENTAL

 

Media temperature

0...+60 °C

Pressure resistance

PN 10

Protection rating

IP 65

 

 

MATERIALS

 

Housing

PVC

Rotor

PVDF / 1.4310 or titanium (10 stainless steel clamps or 10 titanium clamps)

Bearing

Iglidur X

Axis

Ceramics ZrO2-TZP

Seal

Fluororubber FKM (optional: EPDM, NBR)

 

 

MECHANICAL

 

Mechanical connection

Insertion probe with union nut (welded-on nozzle and tapping clamps available as accessories)

Union nut tightening torque

30 Nm

Electrical connection

2 m cable, or round plug connector M12x1, 4-pin

Connection by output, P / N

2 m cable or M12x1 without LED

Connection by output, A

2 m cable

Connection by output, I / U / F / S

M12x1 with LED

Wiring, P / N

Brown: +10...30 V DC; black: output; blue: 0 V

Wiring, A

Brown: +7...12 V DC; blue: 0 V

Wiring, I / U / F / S

1 brown: 10/15...30 V DC; 2 white: programming; 3 blue: 0 V; 4 black: output signal

Weight

Approx. 0.250 kg

Installation

Run-in and run-out sections of 10 x D of the pipe diameter; best position: flow from bottom to top, or horizontal piping with the sensor at an angle of 45° downwards

 

 

ACCESSORIES

 

Accessories

Round plug connector KB04 / cable K04PU; weld-on nozzle VKI-032K; tapping clamps BBI-032H; measuring tubes MH-032H; device configurator ECI-3

Options

Special versions available on request

 

 

APPROVALS

 

Conformity

CE

Drawing

Senseca-RRI-032-Dimensional-Drawing

Downloads

Senseca-RRI-032-Datasheet-EN DownloadSenseca-RRI-032-Datasheet-EN