WETEC

ECD

FCX80 Hazardous Location Free Chlorine Analyzer

WaterWater Quality Measurement

Panel-mounted free chlorine analyzer for hazardous locations with automatic pH compensation and flow control.

  • Free chlorine measurement: 0.05–20 ppm (standard range) or 0.01–5.00 ppm (low range)

  • Reagentless monitoring and EPA Method 334.0 compliance

  • Sample flow rate: 38–300 L/hr (10–80 gal/hr)

  • 4–20 mA output, optional pH output, Modbus RTU and three alarm relays

  • X80 analyzer/transmitter with graphical LCD and 24 VDC power supply

Quantity
1

Overview

The ECD FCX80 is a panel-mounted free chlorine analyzer designed for hazardous locations, providing reagentless monitoring of drinking water, rinse water, cooling water and other fresh water samples. It offers a standard measurement range of 0.05–20 ppm or a low range of 0.01–5.00 ppm and complies with EPA Method 334.0 for drinking water measurement.

The system incorporates a free chlorine sensor, a pH sensor, a constant-head flow control device and an X80 analyzer/transmitter. Automatic pH compensation ensures accurate compensation for samples between pH 6 and 9, while the flow control device maintains optimum sensor flow at incoming sample flow rates of 38–300 L/hr.

The X80 operates on 24 VDC and features a graphical LCD, a 4–20 mA output for free chlorine, an optional 4–20 mA output for pH, Modbus RTU communication and three alarm relays. The plug-and-play design simplifies installation, with calibration performed by DPD comparison.

Typical Applications

  • Free chlorine monitoring in drinking water

  • Free chlorine measurement in rinse water

  • Free chlorine monitoring in cooling water

  • Free chlorine analysis in other fresh water samples

Key Features

  • Panel-mounted, plug-and-play design for hazardous locations

  • Free chlorine measurement range of 0.05–20 ppm (standard) or 0.01–5.00 ppm (low range)

  • Reagentless amperometric free chlorine measurement

  • Automatic pH compensation for samples between pH 6 and 9

  • Constant-head flow control device supporting 38–300 L/hr sample flow

  • Compliance with EPA Method 334.0 for drinking water measurement

  • X80 analyzer/transmitter with graphical LCD and configurable line, bar or gauge displays

  • 4–20 mA free chlorine output, optional 4–20 mA pH output, Modbus RTU and three alarm relays

  • 24 VDC power supply

  • ATEX/IECEx or FM-approved X80 transmitter and sensors, depending on configuration

  • Non-intrusive calibration by DPD comparison

  • ECD digital intelligent sensors with factory calibration and data storage

Benefits

  • Lower operating costs through reagentless monitoring

  • Easy installation with a complete, ready-to-use panel-mounted system

  • Eliminates the need for expensive pH conditioning systems

  • Maintains optimum sensor flow without pressure regulators or rotameters

  • Reduced risk of clogging and blockages with large flow tubes and cells

  • Easy cleaning and routine maintenance

  • Suitable for drinking water monitoring in accordance with EPA Method 334.0

  • Supports operation in hazardous locations with appropriately approved instruments

  • Easy interpretation of measurements through graphical and numerical displays

  • Simple navigation and configuration through an intuitive menu

  • Non-intrusive calibration without opening the enclosure or declassifying the area

Specifications

Sensor and Measurement

Sensor type

Polarographic

Electrode materials

Gold/Silver

Membrane material

PTFE

Sensor communication

Digital communication

Free chlorine measurement range (standard range)

0.05–20 ppm

Free chlorine measurement range (low range)

0.01–5.00 ppm

pH measurement range

0–14 pH

Response time

T90 in 2 minutes

Electrolyte life

Up to 12 months

Calibration method

DPD comparison

 

 

Flow Control and Process Connections

Flow control device

Constant-head flow control device (CFD)

Minimum and maximum sample flow

38–300 L/hr (10–80 gal/hr)

Sample drain condition

Atmospheric pressure

Inlet connection

¼″ barb fitting (¼″ FNPT)

Drain connection

¾″ FNPT

Wetted materials

PVC, PP, PVDF, PTFE, glass and 316 stainless steel

 

 

Operating Conditions

Operating temperature (sensor and flow train)

0–50 °C (32–122 °F)

 

 

X80 Analyzer/Transmitter

Chlorine measurement indication

000.0–999.9, ppb/ppm auto-ranging

Temperature measurement range

0–100 °C (32–212 °F)

pH compensation

pH 5–10; accurate compensation between pH 6 and 9, with accuracy degrading rapidly above pH 9

Display type

Graphical LCD

Display resolution

128 × 64 pixels

Display dimensions

2.75″ × 1.5″

Display colour

Black on grey background or blue on white background with LED backlight

Graphical display formats

Line, bar or gauge

 

 

Outputs and Communication

Free chlorine analogue output

1 × 4–20 mA, set to sensor range

pH analogue output

1 × 4–20 mA (optional), set to 0–14 pH

Digital communication

Modbus RTU

Alarm relays

3 × SPDT, Form C

Alarm relay rating

250 VAC, 10 A

 

 

Power Supply

Nominal supply voltage

24 VDC

Input voltage range

18–36 VDC

Minimum power requirement

250 mW

 

 

System Configuration

Mounting

Panel-mounted

System design

Plug-and-play

Integrated components

Free chlorine sensor, pH sensor, constant-head flow control device and X80 analyzer/transmitter

 

 

Compliance and Approvals

Drinking water measurement compliance

EPA Method 334.0

Hazardous location approvals

ATEX/IECEx or FM-approved X80 transmitter and sensors, depending on model configuration

Downloads

FCX80 Free Chlorine Analyzer Brochure DownloadFCX80 Free Chlorine Analyzer Brochure