WETEC

Senseca

FIS Magnetic-Inductive Flow Probe for Conductive Liquids

WaterFlow & Velocity Measurement & Monitoring

Magnetic-inductive flow probe for conductive liquids and sludges

  • Measures the flow velocity of conductive, largely homogeneous liquids, pastes and slurries (also with solids), with factory-set full scales of 1...8 m/s in 1 m/s steps.

  • One probe fits DN 50...DN 400 pipes with welded-on nozzles, or DN 50...DN 150 with the plastic fixing clip, and the complete probe can be removed without opening the pipe to the medium.

  • Passive 4...20 mA output, 24 V DC supply, Pg 9 cable gland (IP 65) or M12x1 round plug (IP 67), probe in stainless steel 1.4435 with zirconium oxide ceramic insulation.

Quantity
1

Overview

The Senseca FIS is a magnetic-inductive flow probe that measures the local flow velocity of conductive, largely homogeneous liquids, pastes and sludges, including media with solids content.

One probe covers a wide pipe range: welded sleeves for DN 50...DN 400 or a plastic mounting clamp for DN 50...DN 150. The complete probe can be withdrawn without creating an opening to the medium, so only the electronics section needs replacing in case of a defect. A passive 4...20 mA output sends the measured velocity to the control system.

Typical applications

  • Flow measurement in conductive liquids

  • Flow measurement in pastes and sludges, including media with solids content

  • Pipelines from DN 50 to DN 400 with welded sleeves, or DN 50 to DN 150 with a plastic mounting clamp

  • Installations where the sensor must be serviced without opening the process to the medium

Key Features

  • Magnetic-inductive principle with no moving parts

  • Suitable for conductive, largely homogeneous liquids, pastes and slurries, also with solids content

  • Welded sleeves (DN 50...DN 400) or plastic mounting clamp (DN 50...DN 150)

  • Full scale values of 1...8 m/s in 1 m/s steps

  • Passive 4...20 mA current output

  • ZERO CAL button for zero point adjustment

  • Automatic self-test at commissioning, with status signalled through the current output

  • Pg 9 cable gland or 4-pole M12x1 round connector

  • Complete probe removable without opening the pipe to the medium

Benefits

  • Wide pipe coverage: one probe fits DN 50...DN 400 with welded sleeves or DN 50...DN 150 with clamp

  • Service without loss of medium: the probe can be withdrawn without opening the pipe to the medium, and only the electronics section is replaced in case of a defect

  • Clear 4...20 mA scaling thanks to the factory-set full scale value

  • Robust construction in stainless steel 1.4435 with zirconium oxide ceramic insulation

  • Ingress protection up to IP 67 with the round connector version

Specifications

INPUT

 

Measuring principle

Magnetic-inductive

Medium

Conductive, largely homogeneous fluids, pastes and slurries, also with solids components

Electrical conductivity

Min. 20 µS/cm

Nominal width

DN 50...400 welded-on nozzle; DN 50...150 tapping sleeve

Process connection

Welded-on nozzle, tapping sleeve

Metering ranges

Full scales 1...8 m/s in steps of 1 m/s

 

 

MEASURING ACCURACY

 

Measurement accuracy

±5 % of the measured value (±2 % of the measured value when calibrated on the spot), from 3 cm/s

Repeatability

±2 % of the measured value

Time constant

5 seconds, fixed

 

 

OUTPUTS

 

Output

4...20 mA (passive current output)

Load resistance

Max. 500 Ohm

Device status

3 mA: the device is still conducting the self-test or has detected an error; 4...20 mA: device is in measurement mode and shows the currently measured speed

 

 

POWER REQUIREMENT

 

Supply voltage

24 V DC ±10 %

Current consumption

50 mA (at 24 V DC and 20 °C)

 

 

ENVIRONMENTAL

 

Medium temperature

-25...+150 °C

Ambient temperature

-25...+60 °C

Operating pressure

Max. 25 bar for welded-on nozzle; max. 10 bar for tapping sleeve

Ingress protection

IP 65 cable screw gland; IP 67 round plug connector

 

 

MATERIALS

 

Probe

Stainless steel 1.4435

Insulation

Ceramic (zirconium oxide)

Tapping sleeve

PP, 1.4305

Electronics housing

Stainless steel 1.4305; FKM and Klingerit

 

 

MECHANICAL

 

Electrical connection

Cable screw gland Pg 9 (cable not included) or round plug connector M12x1, 4-pole

Wiring, round plug connector

1 = supply voltage 24 V; 2 = current loop +; 3 = GND (0 V); 4 = current loop -

Functional earth

FE < 10 Ohm (protective earth), must be installed

Range setting

Full scale value set in the factory by DIP switches (1...8 m/s)

Zero point setting

Fill the piping completely, flow speed must be zero, press the ZERO CAL button; after one minute the device has self-calibrated

Installation

Run-in and run-out sections at least 10 x pipework diameter; the arrow on the electronics insert must point in the direction of flow

Removal

Complete measuring probe can be removed without creating an opening to the medium

Weight

2.4 kg excluding tapping sleeve

 

 

APPROVALS

 

Conformity

CE

Drawing

Senseca-FIS-Dimensional-Drawing

Downloads

Senseca-FIS-Datasheet-EN DownloadSenseca-FIS-Datasheet-EN