Senseca
FIS Magnetic-Inductive Flow Probe for Conductive Liquids
Magnetic-inductive flow probe for conductive liquids and sludges
Measures the flow velocity of conductive, largely homogeneous liquids, pastes and slurries (also with solids), with factory-set full scales of 1...8 m/s in 1 m/s steps.
One probe fits DN 50...DN 400 pipes with welded-on nozzles, or DN 50...DN 150 with the plastic fixing clip, and the complete probe can be removed without opening the pipe to the medium.
Passive 4...20 mA output, 24 V DC supply, Pg 9 cable gland (IP 65) or M12x1 round plug (IP 67), probe in stainless steel 1.4435 with zirconium oxide ceramic insulation.
Overview
The Senseca FIS is a magnetic-inductive flow probe that measures the local flow velocity of conductive, largely homogeneous liquids, pastes and sludges, including media with solids content.
One probe covers a wide pipe range: welded sleeves for DN 50...DN 400 or a plastic mounting clamp for DN 50...DN 150. The complete probe can be withdrawn without creating an opening to the medium, so only the electronics section needs replacing in case of a defect. A passive 4...20 mA output sends the measured velocity to the control system.
Typical applications
Flow measurement in conductive liquids
Flow measurement in pastes and sludges, including media with solids content
Pipelines from DN 50 to DN 400 with welded sleeves, or DN 50 to DN 150 with a plastic mounting clamp
Installations where the sensor must be serviced without opening the process to the medium
Key Features
Magnetic-inductive principle with no moving parts
Suitable for conductive, largely homogeneous liquids, pastes and slurries, also with solids content
Welded sleeves (DN 50...DN 400) or plastic mounting clamp (DN 50...DN 150)
Full scale values of 1...8 m/s in 1 m/s steps
Passive 4...20 mA current output
ZERO CAL button for zero point adjustment
Automatic self-test at commissioning, with status signalled through the current output
Pg 9 cable gland or 4-pole M12x1 round connector
Complete probe removable without opening the pipe to the medium
Benefits
Wide pipe coverage: one probe fits DN 50...DN 400 with welded sleeves or DN 50...DN 150 with clamp
Service without loss of medium: the probe can be withdrawn without opening the pipe to the medium, and only the electronics section is replaced in case of a defect
Clear 4...20 mA scaling thanks to the factory-set full scale value
Robust construction in stainless steel 1.4435 with zirconium oxide ceramic insulation
Ingress protection up to IP 67 with the round connector version
Specifications
INPUT |
|
Measuring principle | Magnetic-inductive |
Medium | Conductive, largely homogeneous fluids, pastes and slurries, also with solids components |
Electrical conductivity | Min. 20 µS/cm |
Nominal width | DN 50...400 welded-on nozzle; DN 50...150 tapping sleeve |
Process connection | Welded-on nozzle, tapping sleeve |
Metering ranges | Full scales 1...8 m/s in steps of 1 m/s |
MEASURING ACCURACY |
|
Measurement accuracy | ±5 % of the measured value (±2 % of the measured value when calibrated on the spot), from 3 cm/s |
Repeatability | ±2 % of the measured value |
Time constant | 5 seconds, fixed |
OUTPUTS |
|
Output | 4...20 mA (passive current output) |
Load resistance | Max. 500 Ohm |
Device status | 3 mA: the device is still conducting the self-test or has detected an error; 4...20 mA: device is in measurement mode and shows the currently measured speed |
POWER REQUIREMENT |
|
Supply voltage | 24 V DC ±10 % |
Current consumption | 50 mA (at 24 V DC and 20 °C) |
ENVIRONMENTAL |
|
Medium temperature | -25...+150 °C |
Ambient temperature | -25...+60 °C |
Operating pressure | Max. 25 bar for welded-on nozzle; max. 10 bar for tapping sleeve |
Ingress protection | IP 65 cable screw gland; IP 67 round plug connector |
MATERIALS |
|
Probe | Stainless steel 1.4435 |
Insulation | Ceramic (zirconium oxide) |
Tapping sleeve | PP, 1.4305 |
Electronics housing | Stainless steel 1.4305; FKM and Klingerit |
MECHANICAL |
|
Electrical connection | Cable screw gland Pg 9 (cable not included) or round plug connector M12x1, 4-pole |
Wiring, round plug connector | 1 = supply voltage 24 V; 2 = current loop +; 3 = GND (0 V); 4 = current loop - |
Functional earth | FE < 10 Ohm (protective earth), must be installed |
Range setting | Full scale value set in the factory by DIP switches (1...8 m/s) |
Zero point setting | Fill the piping completely, flow speed must be zero, press the ZERO CAL button; after one minute the device has self-calibrated |
Installation | Run-in and run-out sections at least 10 x pipework diameter; the arrow on the electronics insert must point in the direction of flow |
Removal | Complete measuring probe can be removed without creating an opening to the medium |
Weight | 2.4 kg excluding tapping sleeve |
APPROVALS |
|
Conformity | CE |
Drawing

Downloads
| Senseca-FIS-Datasheet-EN | DownloadSenseca-FIS-Datasheet-EN |
|---|
Related Products

Senseca
UR1-G Flow Switch for Water with Internal Thread
Compact paddle flow switch for water lines with reed switch, DN 10.50 internal threads G 3/8.G 2, PN 25 and medium temperatures up to 110 °C.
Learn More
Senseca
UB1 Paddle Flow Switch for Water Lines DN 25 to DN 200
Paddle flow switch for water lines DN 25 to DN 200 with metal bellows, microswitch changeover output, transparent cover for visual check and IP65 housing, R…
Learn More
Senseca
TMS500 Thermal Flow Meter for Compressed Air and Gases
Thermal flow meter for compressed air and gases, measuring flow, consumption and velocity in pipes up to DN 300, with 4.20 mA, RS 485 Modbus RTU and pulse…
Learn More
Senseca
EFK2 Flow Switch for Liquid Media Monitoring
Flow switch for liquid media monitoring, measuring water flow velocity at 2.150 or 3.300 cm/s with calorimetric sensing, adjustable switching point, LED…
Learn More