Thermal flow meter for compressed air and gases

  • Calorimetric insertion sensor that measures flow, consumption and velocity of compressed air and gases such as nitrogen, oxygen, CO2, argon and nitrous oxide, with no additional pressure or temperature compensation.

  • Mounts through a standard G ½ ball valve and can be installed under pressure, with an engraved depth scale for positioning the sensor in the pipe center, for pipes up to DN 300 and operating pressure up to 50 bar.

  • 4...20 mA, RS 485 Modbus RTU and pulse outputs, with an optional 1.8" TFT display showing current and total consumption (counter up to 1,999,999,999 m³).

Quantity
1

Overview

The Senseca TMS500 is a thermal insertion flow meter that measures flow, consumption and velocity of compressed air and gases such as nitrogen, oxygen, CO2, argon and nitrous oxide. It helps users identify leakage air, check usage and build a clearer compressed air balance.

The calorimetric measuring principle uses the cooling of a heated sensor, so no additional pressure or temperature compensation is required. The sensor mounts through a standard G ½ ball valve, can be installed under pressure and has an engraved depth scale for positioning in the pipe center. It offers 4...20 mA, RS 485 Modbus RTU and pulse outputs, for pipes up to DN 300 and operating pressure up to 50 bar.

Typical applications

  • Mobile compressed air measurement in front of single machines and systems

  • Flow measurement of process gases such as nitrogen, CO2, oxygen, argon and nitrous oxide

  • Flow measurement at nitrogen generators

  • Determining leakage air and leak rate

  • Accounting and consumption measurement of compressed air

Key Features

  • Calorimetric measurement of flow, consumption and velocity, with no pressure or temperature compensation needed

  • No moving parts

  • Selectable units: m³/h, m³/min, l/min, l/s, ft/min, cfm, m/s, kg/h, kg/min and kg/s

  • Consumption counter up to 1,999,999,999 m³, resettable to zero from the keypad

  • Inner pipe diameter set with the keypad, with an engraved depth scale for positioning the sensor in the pipe center

  • Factory reference conditions DIN 1945 and ISO 1217 at 20 °C and 1000 mbar; other standards can be set with the display keys (optional) or the service software

  • Retaining ring prevents the probe from being pushed out by the operating pressure during installation and removal

  • Probe lengths from 120 mm to 700 mm

  • 4...20 mA, pulse and RS 485 Modbus RTU outputs

  • Optional 1.8" TFT display showing current consumption and total consumption

Benefits

  • Install under pressure: G ½ ball valve mounting allows insertion without depressurizing the line

  • Low pressure loss: the calorimetric sensor measures without moving parts and creates negligible pressure loss

  • Broad gas coverage: one sensor family for air, nitrogen, oxygen, CO2, argon and nitrous oxide

  • Industrial outputs: connect via 4...20 mA, pulse output or RS 485 Modbus RTU for automation systems

  • Clear on-site values: the optional display shows current consumption and total consumption directly

  • High-speed option: versions cover up to 92.7 m/s, 185 m/s or 224 m/s, depending on version

Specifications

INPUT

 

Measurement

Flow, consumption and velocity

Measuring principle

Calorimetric measurement

Sensor

Pt45, Pt1000

Measuring medium

Air, gases

Measuring range (velocity)

Standard version up to 92.7 m/s; max version up to 185 m/s; high speed version up to 224 m/s

Selectable units

m³/h (factory setting), m³/min, l/min, l/s, ft/min, cfm, m/s, kg/h, kg/min, kg/s

Reference conditions

Factory setting DIN 1945, ISO 1217 at 20 °C and 1000 mbar; other standards can be set with the display keys (optional) or the service software

 

 

MEASURING ACCURACY

 

Accuracy

±1.5 % of measured value, ±0.3 % of full scale

 

 

OUTPUTS

 

Analog output

4...20 mA, max. burden < 500 Ohm

Pulse output

Potential-free (dry contact), passive: max. 48 V DC, 500 mA; 1 pulse per m³ or per l, adjustable with the display keys

Digital output

RS 485 interface (Modbus RTU)

 

 

DISPLAY

 

Display

Optional TFT 1.8", resolution 220 x 176

Display values

Current consumption (e.g. m³/h, l/min) and total consumption (meter reading) in m³ or l

Consumption counter

Up to 1,999,999,999 m³, resettable to zero via keypad

 

 

POWER REQUIREMENT

 

Supply voltage

24 V DC, smoothed, ±15 %

Power consumption

Max. 5 W

 

 

ENVIRONMENTAL

 

Operating temperature

-30...80 °C

Operating pressure

Up to 50 bar

Protection class

IP65

 

 

MATERIALS

 

Material

Stainless steel 1.4301 / 1.4404

 

 

MECHANICAL

 

Mounting thread

G ½" (ISO 228/1)

Pipe diameters

Up to DN 300

Probe length

120, 160, 220 (standard), 300, 400, 500, 600 or 700 mm

Electrical connection

Two connectors (A and B) on the housing; 5-pole M12 cable socket included

Installation

Through a standard G ½" ball valve, can be installed under pressure; retaining ring prevents the probe from being pushed out by the operating pressure; engraved depth scale for positioning in the pipe center

Inner pipe diameter

Adjustable via keys

 

 

OPTIONS

 

Gas type

Air (measuring range according to DIN 1945 / ISO 1217); argon, carbon dioxide (CO2), oxygen, nitrogen (measuring range according to DIN 1343); special medium; measuring range to be specified

Calibration accuracy

±1.5 % of measured value (standard); ±1.0 % of measured value; on request: special calibration via 5-point ISO certificate

Display

Without display, or with display

Drawing

Senseca-TMS500-Dimensional-Drawing

Downloads