Senseca
TMS500 Thermal Flow Meter for Compressed Air and Gases
Thermal flow meter for compressed air and gases
Calorimetric insertion sensor that measures flow, consumption and velocity of compressed air and gases such as nitrogen, oxygen, CO2, argon and nitrous oxide, with no additional pressure or temperature compensation.
Mounts through a standard G ½ ball valve and can be installed under pressure, with an engraved depth scale for positioning the sensor in the pipe center, for pipes up to DN 300 and operating pressure up to 50 bar.
4...20 mA, RS 485 Modbus RTU and pulse outputs, with an optional 1.8" TFT display showing current and total consumption (counter up to 1,999,999,999 m³).
Overview
The Senseca TMS500 is a thermal insertion flow meter that measures flow, consumption and velocity of compressed air and gases such as nitrogen, oxygen, CO2, argon and nitrous oxide. It helps users identify leakage air, check usage and build a clearer compressed air balance.
The calorimetric measuring principle uses the cooling of a heated sensor, so no additional pressure or temperature compensation is required. The sensor mounts through a standard G ½ ball valve, can be installed under pressure and has an engraved depth scale for positioning in the pipe center. It offers 4...20 mA, RS 485 Modbus RTU and pulse outputs, for pipes up to DN 300 and operating pressure up to 50 bar.
Typical applications
Mobile compressed air measurement in front of single machines and systems
Flow measurement of process gases such as nitrogen, CO2, oxygen, argon and nitrous oxide
Flow measurement at nitrogen generators
Determining leakage air and leak rate
Accounting and consumption measurement of compressed air
Key Features
Calorimetric measurement of flow, consumption and velocity, with no pressure or temperature compensation needed
No moving parts
Selectable units: m³/h, m³/min, l/min, l/s, ft/min, cfm, m/s, kg/h, kg/min and kg/s
Consumption counter up to 1,999,999,999 m³, resettable to zero from the keypad
Inner pipe diameter set with the keypad, with an engraved depth scale for positioning the sensor in the pipe center
Factory reference conditions DIN 1945 and ISO 1217 at 20 °C and 1000 mbar; other standards can be set with the display keys (optional) or the service software
Retaining ring prevents the probe from being pushed out by the operating pressure during installation and removal
Probe lengths from 120 mm to 700 mm
4...20 mA, pulse and RS 485 Modbus RTU outputs
Optional 1.8" TFT display showing current consumption and total consumption
Benefits
Install under pressure: G ½ ball valve mounting allows insertion without depressurizing the line
Low pressure loss: the calorimetric sensor measures without moving parts and creates negligible pressure loss
Broad gas coverage: one sensor family for air, nitrogen, oxygen, CO2, argon and nitrous oxide
Industrial outputs: connect via 4...20 mA, pulse output or RS 485 Modbus RTU for automation systems
Clear on-site values: the optional display shows current consumption and total consumption directly
High-speed option: versions cover up to 92.7 m/s, 185 m/s or 224 m/s, depending on version
Specifications
INPUT |
|
Measurement | Flow, consumption and velocity |
Measuring principle | Calorimetric measurement |
Sensor | Pt45, Pt1000 |
Measuring medium | Air, gases |
Measuring range (velocity) | Standard version up to 92.7 m/s; max version up to 185 m/s; high speed version up to 224 m/s |
Selectable units | m³/h (factory setting), m³/min, l/min, l/s, ft/min, cfm, m/s, kg/h, kg/min, kg/s |
Reference conditions | Factory setting DIN 1945, ISO 1217 at 20 °C and 1000 mbar; other standards can be set with the display keys (optional) or the service software |
MEASURING ACCURACY |
|
Accuracy | ±1.5 % of measured value, ±0.3 % of full scale |
OUTPUTS |
|
Analog output | 4...20 mA, max. burden < 500 Ohm |
Pulse output | Potential-free (dry contact), passive: max. 48 V DC, 500 mA; 1 pulse per m³ or per l, adjustable with the display keys |
Digital output | RS 485 interface (Modbus RTU) |
DISPLAY |
|
Display | Optional TFT 1.8", resolution 220 x 176 |
Display values | Current consumption (e.g. m³/h, l/min) and total consumption (meter reading) in m³ or l |
Consumption counter | Up to 1,999,999,999 m³, resettable to zero via keypad |
POWER REQUIREMENT |
|
Supply voltage | 24 V DC, smoothed, ±15 % |
Power consumption | Max. 5 W |
ENVIRONMENTAL |
|
Operating temperature | -30...80 °C |
Operating pressure | Up to 50 bar |
Protection class | IP65 |
MATERIALS |
|
Material | Stainless steel 1.4301 / 1.4404 |
MECHANICAL |
|
Mounting thread | G ½" (ISO 228/1) |
Pipe diameters | Up to DN 300 |
Probe length | 120, 160, 220 (standard), 300, 400, 500, 600 or 700 mm |
Electrical connection | Two connectors (A and B) on the housing; 5-pole M12 cable socket included |
Installation | Through a standard G ½" ball valve, can be installed under pressure; retaining ring prevents the probe from being pushed out by the operating pressure; engraved depth scale for positioning in the pipe center |
Inner pipe diameter | Adjustable via keys |
OPTIONS |
|
Gas type | Air (measuring range according to DIN 1945 / ISO 1217); argon, carbon dioxide (CO2), oxygen, nitrogen (measuring range according to DIN 1343); special medium; measuring range to be specified |
Calibration accuracy | ±1.5 % of measured value (standard); ±1.0 % of measured value; on request: special calibration via 5-point ISO certificate |
Display | Without display, or with display |
Drawing

Downloads
| Senseca-TMS500-Datasheet-EN | DownloadSenseca-TMS500-Datasheet-EN |
|---|
Related Products

Senseca
UR1-G Flow Switch for Water with Internal Thread
Compact paddle flow switch for water lines with reed switch, DN 10.50 internal threads G 3/8.G 2, PN 25 and medium temperatures up to 110 °C.
Learn More
Senseca
UB1 Paddle Flow Switch for Water Lines DN 25 to DN 200
Paddle flow switch for water lines DN 25 to DN 200 with metal bellows, microswitch changeover output, transparent cover for visual check and IP65 housing, R…
Learn More
Senseca
EFK2 Flow Switch for Liquid Media Monitoring
Flow switch for liquid media monitoring, measuring water flow velocity at 2.150 or 3.300 cm/s with calorimetric sensing, adjustable switching point, LED…
Learn More
Senseca
RRI-032 Paddle Wheel Flow Transmitter for DN 32 Pipes
Flow transmitter for liquid flow monitoring in pipes from DN 32, with a measuring range of 0.3.6 m/s and PNP/NPN, NAMUR, 4.20 mA, 0.10 V, frequency or limit…
Learn More