Senseca
GHTU Humidity and Temperature Transducer
Humidity and temperature transducer for wall, duct and open-air use.
- Humidity 0.0…100.0 %RH and temperature -40.0…+120.0 °C
- 4…20 mA standard output (0…1 V or 0…10 V optional), with a 4-digit LCD alternating humidity and temperature
- ABS housing, IP65, with min/max memory and adjustable offset and slope
Overview
The GHTU is a humidity and temperature transducer built with the latest microprocessor technology. It measures 0.0…100.0 %RH (temperature compensated) and -40.0…+120.0 °C, and comes in wall, wall/duct, duct, cable and open-air versions. It has a 4-digit LCD and standard signal outputs, in an ABS housing (IP65).
Typical applications
Different versions let the GHTU be used in almost all applications.
- Wall mounting (GHTU-1R-MP, GHTU-1K-MP)
- Duct (channel) mounting (GHTU-1K-MP, GHTU-2K-MP)
- Open-air measurement with the heat absorption hat / weather protection shield (GHTU-SHUT-MP)
- Wall mounting with a separated sensor tube on a 1 m cable and high-humidity sensor (GHTU-KABEL-MP)
Key Features
Precise and flexible humidity and temperature measurement with a built-in display.
- Temperature compensated humidity measurement, with automatic temperature compensation
- 4…20 mA standard output; 0…1 V and 0…10 V options, including galvanically isolated versions
- 4-digit LCD display (approx. 10 mm high) alternating humidity and temperature
- Min/max value memory, offset and slope adjustable, output signal scaleable
- Optional UNI display: show wet bulb temperature, dew point temperature, enthalpy, atmospheric humidity or absolute humidity instead of the humidity value
- Optional high-humidity sensor; optional encapsulated PC board for use where condensation may occur
- Fitting lengths of 50, 220, 300, 400 or 500 mm
Benefits
- Flexible mounting: wall, duct, separated probe and weather shield versions support room, duct and open-air use
- Wide sensor range: measures 0.0…100.0 %RH and sensor temperatures from -40.0…+120.0 °C
- Process-ready output: 4-20 mA is standard; 0-1 V and 0-10 V options are available
- Protected housing: ABS housing and EN 175301-803/A elbow-type plug are rated IP65
- On-site adjustment: min/max memory, offset and slope adjustment, and scalable output support setup
Specifications
SPECIFICATIONS |
|
Humidity measuring range | 0.0…100.0 %RH (temperature compensated) |
Temperature measuring range | -40.0…+120.0 °C or -40.0…+248 °F |
Recommended humidity range | 20.0…80.0 %RH (standard) |
Display options (option UNI) | An alternative display unit can be shown instead of the humidity measuring value, selected via keyboard: |
Accuracy (at 25 °C and in recommended range) | Display, humidity: ±2.5 %RH |
Temperature compensation | Automatically |
Auxiliary energy | 12…30 VDC or 18…30 VDC (for output: 0-10 V) |
Reverse voltage protection | 50 V, permanently |
Permissible impedance (at 4-20 mA) | RA [Ω] ≤ (UV [V] - 12 V) / 0.02 A |
Permissible load (at 0-1(10) V) | RL [Ω] > 3000 Ω |
Display | Approx. 10 mm high, 4-digit LCD display, alternating humidity and temperature display |
Working temperature | Electronics: -25…+50 °C |
Storage temperature | -25…+70 °C |
Relative humidity (electronic) | 0…95 %RH (non-condensing). If there is a risk of condensation due to temperature changes, use the encapsulated or lacquered types (optionally available). |
DESIGN & MOUNTING |
|
Models | GHTU-1R-MP: wall version, standard probe length 50 mm (Product-ID 602585) |
Housing | ABS (IP65) |
Sensor tube | Tube 14 mm Ø, with screw-type protection cap |
Design type Kabel | With separated sensor tube, sensor head (Ø14 x 68 mm) connected to device via 1 m Teflon cable. Includes option high-humidity sensor. |
Design type Shut | Heat absorption hat / weather protection shield, especially designed for measurements in the open air. The measuring results are not influenced by either sun or rain. |
Electric connection | Elbow-type plug acc. to EN 175301-803/A (IP65) |
Mounting | 4 housing holes for wall mounting or by means of plastic tube clamps for duct mounting |
Functions | Min-/max-value memory, offset and slope adjustable, output signal scaleable |
ORDERING CODE | GHTU - 1 - 2 - 3 - 4 - 5 - 6 -GE |
1. Design type | 1R-MP = Surface design |
2. Fitting length EL | -050 = 50 mm (standard for 1R) |
3. Output signal | ... = 4-20 mA (standard) |
4. Options sensor | -00 = Standard sensor |
5. Option | -LACK = Encapsulated PC board |
6. Option | -UNI = Selectable humidity display instead of the standard humidity values |
Downloads
| GHTU Family Datasheet (EN) | DownloadGHTU Family Datasheet (EN) |
|---|
Related Products

Senseca
LPSD18 Sunshine Duration Sensor
Sunshine duration sensor with 16 silicon photodiodes, 120 W/m² WMO threshold and 0–2000 W/m² direct radiation range.
Learn More
Senseca
LPUVA02 UVA radiometer
UVA radiometer for outdoor global irradiance and indoor UVA monitoring.
Learn More
Senseca
LPUVA03 Radiometric Probe
UVA irradiance probe for outdoor monitoring.
Learn More
Senseca
LPPYRHE16 Pyrheliometer
Class B pyrheliometer for direct solar irradiance measurement.
Learn More