  • Pt100 temperature -50…+200 °C and humidity 0…100 %RH, with calculated dew point, wet bulb temperature, absolute humidity and mixing ratio
  • Backlit graphic LCD showing up to three values or trends, with built-in data logging (9000 samples)
  • RS232/RS485 serial ports and 3 analog outputs (4…20 mA, 0…20 mA, 0…10 Vdc or 2…10 Vdc), with optional relays
Quantity
1

Overview

The HD2817T is a smart environmental transmitter for demanding industrial and HVAC applications. It combines precise measurement, easy configuration and advanced data logging, and works as a transmitter, indicator and ON/OFF regulator for real-time monitoring and control of temperature and humidity. It measures temperature and relative humidity while calculating dew point, wet bulb temperature, absolute humidity and mixing ratio, and shows up to three values or trend graphs on its backlit graphic LCD. Each probe is factory-calibrated and can be replaced on site without stopping operations.

Typical applications

Versatile configurations and display options suit a range of installations.

  • Manufacturing environments
  • Cleanrooms
  • Ducts
  • Compressed air lines (with the S.TC2.480.2 and S.481.2 probes, for measuring humidity of the air in pipes)
  • HVAC monitoring

Key Features

Smart measurement, display and logging in one instrument.

  • Simultaneous measurement of temperature and relative humidity, with calculation of dew point, wet bulb temperature, absolute humidity and mixing ratio
  • Backlit graphic LCD showing up to three values or trend graphs
  • Interchangeable probes that can be swapped on site without stopping operations
  • SICRAM2 module in each probe stores its calibration data for seamless replacement
  • Integrated data logging: 9000 samples in up to 256 sessions, intervals from 1 s to 4 min, with lithium battery backup for the clock
  • Current and voltage outputs (3 analog outputs), RS232/RS485 serial ports and optional control/alarm relays
  • Integrated horizontal (S.TO), vertical (S.TV) or remote (S.TC) probe configurations, with remote probes in stainless steel or PBT
  • Power supply options: 24 Vac/dc or 90…240 Vac
  • DeltaLog12 software supplied, downloadable from the website

Benefits

Built for continuous, reliable monitoring.

  • Interchangeable probes: replace the probe without interrupting the process
  • Real-time display: view up to three values or trends on a backlit LCD
  • Accurate and pre-calibrated: each probe is factory-calibrated and stores its data in an internal memory module
  • Built-in data logging: records measurements with configurable intervals and backup timekeeping
  • Flexible integration: multiple outputs (current, voltage, RS232/RS485) and optional relays for control functions

Specifications

INPUTS

 

Temperature sensor

Pt100

Temperature measuring range

-50…+200 °C

Humidity measuring range

0…100 %RH

Dew point TD

-50…+100 °C

Absolute humidity

0…600 g/m³

Mixing ratio

0…2000 g/kg of dry air

Wet bulb temperature

-50…+100 °C

Accuracy of the measured quantities (@24 Vac and 20 °C)

Pt100 temperature: ±0.25 °C
%RH: ±1.5 %RH (0…90 %RH), ±2.0 %RH for remaining range, for T=15…35 °C; ±(1.5 + 1.5% of the measured value) %RH for remaining temperature range

Accuracy of the calculated quantities

Dew point @T=20 °C: ±2 °C DP (-40…-20 °C DP), ±1.5 °C DP (-20…0 °C DP), ±1 °C DP (0…20 °C DP)

Response time

3 min with filter (at 20 °C and 0.5 m/s)

S.TC2.480.2 and S.481.2 probes (humidity of the air in pipes)

Same specifications, with these exceptions:
Temperature measuring range: -40…+60 °C
Dew point measuring range: -40…+60 °C
Dew point accuracy @T=20 °C: ±2 °C DP (-40…0 °C DP), ±1 °C DP (0…+20 °C DP)
Working temperature: -40…+80 °C
Working pressure: 0…16 bar (S.TC2.480.2), -1…8 bar (S.481.2)

 

 

OUTPUTS

 

Communications

Type: RS232C and RS485 Multidrop
Baud rate: 9600 baud; 57600 baud non-permanent

Physical quantities

Measured: Temperature, Relative Humidity
Calculated: Absolute humidity, mixing ratio, dew point, wet bulb temperature

Analog outputs

Number: 3 (HD2817T…)
Output types: 4…20 mA; 0…20 mA; 0…10 Vdc; 2…10 Vdc
Load resistance: current output 500 Ω max; voltage output 100 kΩ min
Resolution: 16 bit
Accuracy: ±0.05% f.s. @20 °C

Relay

Operating relay: 2 x SPDT, 3 A / 250 Vac resistive load
Alarm relay: 1 x SPST normally open, 3 A / 250 Vac resistive load

 

 

INSTRUMENT SPECIFICATIONS

 

Power supply

24 Vac/dc ±10% or 90…240 Vac depending on model, 50…60 Hz
Average consumption 3 W

Datalogger

Storage capacity: 9000 samples in max. 256 sessions
Type of memory: Circular memory
Stored parameters: all the parameters and the status of the outputs
Storage interval: 1, 2, 5, 10, 20, 60 s, 2 and 4 min

Internal clock

Real time with lithium backup battery
Accuracy ±1 min/month

Operating conditions

Temperature: -20…+60 °C
Relative humidity: 0…90 %RH non-condensing
Static operating pressure of the sensors: max. 12 bar

Storage temperature

-30…+80 °C

Weight

600 g

Material

ABS

Protection degree

IP65

PC connection

Multistandard RS232C/RS485 port and one RS232C auxiliary serial port. The auxiliary RS232C port can be connected to a USB PC port via the CP27 cable with integrated USB/RS232C converter.

 

 

ORDERING CODES

 

HD2817 ... D

Probes compatibility: T = model for vertical probe or probe with cable; TO = model for horizontal probe
Relay: 0 = without relay; R = with relay
Power supply: blank = 90…240 Vac; /24 = 24 Vac/dc
D = graphic LCD display

Vertical probe

S.TV: stem length 130 mm, AISI304, P8 filter

Horizontal probes

S.TO1: stem length 135 mm, AISI304, P7 filter
S.TO2: stem length 335 mm, AISI304, P7 filter

Probes with cable for humidity and dew point in compressed air systems or pipes

S.TC2.480.2: cable length 2 m, 1/4" quick coupling Italian standard, AISI 304 measuring chamber
S.481.2: cable length 2 m, G ½" threading, 15 µ sintered AISI 316 stainless steel filter

Probes with cable (S.TC)

Probe length: 1 = 135 mm, 2 = 335 mm
Stem material: blank = AISI 304, P7 filter, max 150 °C; HT = AISI 304, P6 filter, max 170 °C; P = PBT technopolymer
Cable length: 2 = 2 m, 5 = 5 m, 10 = 10 m

Note

All models are supplied with DeltaLog12 software downloadable from the website. Model, power supply and type of probe have to be specified when placing the order.

Drawing

HD2817T_drawing_small (1)

Downloads

HD2817T Family Datasheet (EN) DownloadHD2817T Family Datasheet (EN)
HD2817T Family User Manual DownloadHD2817T Family User Manual