WETEC

Senseca

LP4SL Conductivity Transmitter for Liquids, RS485 Modbus-RTU

WaterProcess & Automation

Conductivity and temperature transmitter with a slim 22 mm design and 4-electrode graphite measuring cell.

  • Conductivity 0…50 mS/cm and temperature −20…+70 °C

  • RS485 Modbus-RTU interface and 6…35 Vdc power supply

  • Stainless steel housing and steel-core support cable

  • IP68 protection for immersion up to 50 m/5 bar

Quantity
1

Overview

The Senseca Conducont LP4SL is a conductivity and temperature transmitter designed for continuous monitoring in fresh water, wastewater and salt water. Its slim 22 mm design is suitable for confined installation points, while the 4-electrode graphite measuring cell provides temperature-compensated conductivity measurements across a range of 0…50 mS/cm. An integrated Pt1000 sensor measures liquid temperature from −20 to +70 °C.

The transmitter features a bidirectional RS485 interface with Modbus-RTU protocol for digital communication and parameter configuration. Its stainless steel housing and reinforced steel-core support cable support operation under demanding environmental conditions. The transmitter operates on a 6…35 Vdc power supply, incorporates overvoltage protection and features IP68 protection for immersion up to 50 m at a maximum pressure of 5 bar.

Typical Applications

  • Conductivity monitoring in fresh water, wastewater and salt water

  • Water quality monitoring in narrow wells, boreholes and small-diameter sounding tubes

  • Combined conductivity and temperature monitoring in industrial liquid processes

  • Digital measurement data integration into monitoring and control systems

Key Features

  • 4-electrode graphite measuring cell

  • Conductivity measurement range of 0…50 mS/cm

  • Integrated Pt1000 temperature sensor with a range of −20…+70 °C

  • Temperature-compensated and non-compensated conductivity measurements

  • Bidirectional RS485 Modbus-RTU interface with configurable baud rate and parameter settings

  • Slim Ø 22 mm sensor design

  • Stainless steel housing

  • Steel-core support cable with shielding braid and PE or PUR sheath options

  • IP68 protection for immersion up to 50 m/5 bar

  • 6…35 Vdc power supply with reverse-polarity protection

  • Integrated overvoltage protection

Benefits

  • Conductivity and temperature measurements from a single transmitter

  • Reliable temperature-compensated conductivity readings, even in contaminated liquids

  • Easy installation in narrow wells and boreholes due to its slim design

  • Flexible integration into digital monitoring and control systems

  • Durable construction for long-term operation under demanding environmental conditions

  • Suitable for continuous submerged operation up to 50 m

  • Enhanced electrical protection against voltage surges and reverse polarity

  • Reduced maintenance requirements under intended operating conditions

Specifications

Conductivity Measurement

Sensor type

Conductive 4-electrode cell

Measurement range (FSI)

0…50 mS/cm

Resolution

≤ 0.1% of measured value (≥ ±0.2 µS/cm)

Calibration curve deviation

≤ ±1% of measured value (≥ ±2 µS/cm)

Temperature compensation

−2%/K, −20…+70 °C (−4…+158 °F)

Reference temperature

+25 °C

Effect of auxiliary power

≤ ±0.002% FSI/V

Long-term zero-point drift

≤ ±0.15% FSI/year

 

 

Temperature Measurement

Sensor type

Pt1000 resistance sensor (IEC 60751)

Measurement range (FSI)

−20…+70 °C (−4…+158 °F)

Resolution

≤ ±0.01 K / FSI ≥ 16 bits

Characteristic curve deviation

≤ ±0.2 K + 0.005 × [Tp]

Effect of auxiliary power

≤ ±0.002% FSI/V

Long-term drift

≤ ±0.1 K/year

 

 

Electronic Output

Interface

Bidirectional RS485, Modbus-RTU

Default baud rate

9600 baud

Configurable baud rate

4800…38400 baud

Input resistance

112 Ω

Conductivity response time

t₉₀ ≤ 2 s (td = 0 s)

Temperature response time

t₉₀ ≤ 60 s (td = 0 s)

 

 

Auxiliary Power

Supply voltage (Us)

6…35 Vdc

Reverse-polarity protection

Provided

Residual ripple

≤ 2 Vpp

Input current (Is)

≤ 15 mA (no load)

Turn-on delay time

≤ 4 s (td = 0 s)

 

 

Ambient and Process Conditions

Process temperature (Tp)

−20…+70 °C (−4…+158 °F)

Process pressure

≤ 5 bar

Ambient temperature (Ta)

−20…+70 °C (−4…+158 °F)

Ingress protection

IP68 (≤ 50 m / ≤ 5 bar), EN/IEC 60529

Climate class

4K4H (EN/IEC 60721-3-4)

Shock resistance

50 g (11 ms), EN/IEC 60068-2-27

Vibration resistance

20 g (10…2000 Hz), EN/IEC 60068-2-6

Pollution degree

4

Operating altitude

2,000 m above sea level

 

 

Electrical Protection and EMC

Surge protection

Integrated (EN/IEC 61000-4-5)

Insulation voltage

≥ 50 Vdc

Rated discharge current

10 kA (8/20 µs)

Protection class

III

Electromagnetic compatibility (EMC)

Class B equipment / industrial environment (EN/IEC 61326)

 

 

Mechanical Specifications and Materials

Sensor diameter

Ø 22 mm

Housing material

Stainless steel 1.4404/316L

Measuring cell materials

Graphite, epoxy

Process seal material

FKM/FPM

Weight

0.25 kg + (L1 × 0.068 kg/m)

 

 

Support Cable

Cable construction

Steel core with shielding braid

Cable sheath material

PE or PUR

Maximum cable length (L1)

300 m

Breaking force of steel shield

≥ 920 N

Bending radius

≥ 100 mm

Strand cross-section

0.22 mm²

Resistance

90 Ω/km

 

 

Electrical Connection

Connection option [14-K]

Cable with pre-terminated strands

Connection option [14-H]

Cable with Hydrolog HLF4 assembly

Connection option [14-0]

Cable without termination

 

 

RS485 Connection Cable Requirements

Cable type

4-wire cable according to EIA485 recommendation

Impedance

135…165 Ω at 3…20 MHz

Cable capacitance

< 30 pF/m

Cable diameter

> 0.64 mm

Cable cross-section

0.34 mm² / AWG 22

Loop resistance

< 110 Ω/km

Shielding

Braided shield / shielding foil

Cable length

≤ 1,200 m at 38,400 baud

 

 

Storage and Transport Conditions

Storage and transport temperature

−20…+85 °C

Relative humidity

20…85%

 

 

Reliability

Mean time to failure (MTTF)

256.4 years

 

 

Compliance and Standards

Conformity marking

CE

RoHS Directive

2011/65/EU

General Product Safety Regulation (GPSR)

Regulation (EU) 2023/988

EMC Directive

2014/30/EU

Restriction of hazardous substances

EN 63000:2019

Safety of electrical measuring instruments

EN 61010-1:2023

EMC requirements for measuring instruments

EN 61326-1:2022

Particular EMC requirements

EN 61326-2-3:2022

Drawing

LP4SL Conductivity Transmitter for Liquids, RS485 Modbus-RTU Drawing

Downloads

LP4SL User Manual DownloadLP4SL User Manual
LP4SL Family CE Declaration of Conformity DownloadLP4SL Family CE Declaration of Conformity