Senseca
LP4SL Conductivity Transmitter for Liquids, RS485 Modbus-RTU
Conductivity and temperature transmitter with a slim 22 mm design and 4-electrode graphite measuring cell.
Conductivity 0…50 mS/cm and temperature −20…+70 °C
RS485 Modbus-RTU interface and 6…35 Vdc power supply
Stainless steel housing and steel-core support cable
IP68 protection for immersion up to 50 m/5 bar
Overview
The Senseca Conducont LP4SL is a conductivity and temperature transmitter designed for continuous monitoring in fresh water, wastewater and salt water. Its slim 22 mm design is suitable for confined installation points, while the 4-electrode graphite measuring cell provides temperature-compensated conductivity measurements across a range of 0…50 mS/cm. An integrated Pt1000 sensor measures liquid temperature from −20 to +70 °C.
The transmitter features a bidirectional RS485 interface with Modbus-RTU protocol for digital communication and parameter configuration. Its stainless steel housing and reinforced steel-core support cable support operation under demanding environmental conditions. The transmitter operates on a 6…35 Vdc power supply, incorporates overvoltage protection and features IP68 protection for immersion up to 50 m at a maximum pressure of 5 bar.
Typical Applications
Conductivity monitoring in fresh water, wastewater and salt water
Water quality monitoring in narrow wells, boreholes and small-diameter sounding tubes
Combined conductivity and temperature monitoring in industrial liquid processes
Digital measurement data integration into monitoring and control systems
Key Features
4-electrode graphite measuring cell
Conductivity measurement range of 0…50 mS/cm
Integrated Pt1000 temperature sensor with a range of −20…+70 °C
Temperature-compensated and non-compensated conductivity measurements
Bidirectional RS485 Modbus-RTU interface with configurable baud rate and parameter settings
Slim Ø 22 mm sensor design
Stainless steel housing
Steel-core support cable with shielding braid and PE or PUR sheath options
IP68 protection for immersion up to 50 m/5 bar
6…35 Vdc power supply with reverse-polarity protection
Integrated overvoltage protection
Benefits
Conductivity and temperature measurements from a single transmitter
Reliable temperature-compensated conductivity readings, even in contaminated liquids
Easy installation in narrow wells and boreholes due to its slim design
Flexible integration into digital monitoring and control systems
Durable construction for long-term operation under demanding environmental conditions
Suitable for continuous submerged operation up to 50 m
Enhanced electrical protection against voltage surges and reverse polarity
Reduced maintenance requirements under intended operating conditions
Specifications
Conductivity Measurement | |
|---|---|
Sensor type | Conductive 4-electrode cell |
Measurement range (FSI) | 0…50 mS/cm |
Resolution | ≤ 0.1% of measured value (≥ ±0.2 µS/cm) |
Calibration curve deviation | ≤ ±1% of measured value (≥ ±2 µS/cm) |
Temperature compensation | −2%/K, −20…+70 °C (−4…+158 °F) |
Reference temperature | +25 °C |
Effect of auxiliary power | ≤ ±0.002% FSI/V |
Long-term zero-point drift | ≤ ±0.15% FSI/year |
Temperature Measurement | |
|---|---|
Sensor type | Pt1000 resistance sensor (IEC 60751) |
Measurement range (FSI) | −20…+70 °C (−4…+158 °F) |
Resolution | ≤ ±0.01 K / FSI ≥ 16 bits |
Characteristic curve deviation | ≤ ±0.2 K + 0.005 × [Tp] |
Effect of auxiliary power | ≤ ±0.002% FSI/V |
Long-term drift | ≤ ±0.1 K/year |
Electronic Output | |
|---|---|
Interface | Bidirectional RS485, Modbus-RTU |
Default baud rate | 9600 baud |
Configurable baud rate | 4800…38400 baud |
Input resistance | 112 Ω |
Conductivity response time | t₉₀ ≤ 2 s (td = 0 s) |
Temperature response time | t₉₀ ≤ 60 s (td = 0 s) |
Auxiliary Power | |
|---|---|
Supply voltage (Us) | 6…35 Vdc |
Reverse-polarity protection | Provided |
Residual ripple | ≤ 2 Vpp |
Input current (Is) | ≤ 15 mA (no load) |
Turn-on delay time | ≤ 4 s (td = 0 s) |
Ambient and Process Conditions | |
|---|---|
Process temperature (Tp) | −20…+70 °C (−4…+158 °F) |
Process pressure | ≤ 5 bar |
Ambient temperature (Ta) | −20…+70 °C (−4…+158 °F) |
Ingress protection | IP68 (≤ 50 m / ≤ 5 bar), EN/IEC 60529 |
Climate class | 4K4H (EN/IEC 60721-3-4) |
Shock resistance | 50 g (11 ms), EN/IEC 60068-2-27 |
Vibration resistance | 20 g (10…2000 Hz), EN/IEC 60068-2-6 |
Pollution degree | 4 |
Operating altitude | 2,000 m above sea level |
Electrical Protection and EMC | |
|---|---|
Surge protection | Integrated (EN/IEC 61000-4-5) |
Insulation voltage | ≥ 50 Vdc |
Rated discharge current | 10 kA (8/20 µs) |
Protection class | III |
Electromagnetic compatibility (EMC) | Class B equipment / industrial environment (EN/IEC 61326) |
Mechanical Specifications and Materials | |
|---|---|
Sensor diameter | Ø 22 mm |
Housing material | Stainless steel 1.4404/316L |
Measuring cell materials | Graphite, epoxy |
Process seal material | FKM/FPM |
Weight | 0.25 kg + (L1 × 0.068 kg/m) |
Support Cable | |
|---|---|
Cable construction | Steel core with shielding braid |
Cable sheath material | PE or PUR |
Maximum cable length (L1) | 300 m |
Breaking force of steel shield | ≥ 920 N |
Bending radius | ≥ 100 mm |
Strand cross-section | 0.22 mm² |
Resistance | 90 Ω/km |
Electrical Connection | |
|---|---|
Connection option [14-K] | Cable with pre-terminated strands |
Connection option [14-H] | Cable with Hydrolog HLF4 assembly |
Connection option [14-0] | Cable without termination |
RS485 Connection Cable Requirements | |
|---|---|
Cable type | 4-wire cable according to EIA485 recommendation |
Impedance | 135…165 Ω at 3…20 MHz |
Cable capacitance | < 30 pF/m |
Cable diameter | > 0.64 mm |
Cable cross-section | 0.34 mm² / AWG 22 |
Loop resistance | < 110 Ω/km |
Shielding | Braided shield / shielding foil |
Cable length | ≤ 1,200 m at 38,400 baud |
Storage and Transport Conditions | |
|---|---|
Storage and transport temperature | −20…+85 °C |
Relative humidity | 20…85% |
Reliability | |
|---|---|
Mean time to failure (MTTF) | 256.4 years |
Compliance and Standards | |
|---|---|
Conformity marking | CE |
RoHS Directive | 2011/65/EU |
General Product Safety Regulation (GPSR) | Regulation (EU) 2023/988 |
EMC Directive | 2014/30/EU |
Restriction of hazardous substances | EN 63000:2019 |
Safety of electrical measuring instruments | EN 61010-1:2023 |
EMC requirements for measuring instruments | EN 61326-1:2022 |
Particular EMC requirements | EN 61326-2-3:2022 |
Drawing

Downloads
| LP4SL User Manual | DownloadLP4SL User Manual |
|---|---|
| LP4SL Family CE Declaration of Conformity | DownloadLP4SL Family CE Declaration of Conformity |
Related Products
Senseca
UNICON-LF-01/02/03 Conductivity Converter
Conductivity converter for liquid purity and concentration monitoring.
Learn More
Senseca
LF4003 Conductivity Cell for Wells and Open Water Systems
4-electrode immersion conductivity cell for wells and open systems up to 100 m depth.
Learn More
Senseca
ORP211 Combined Redox Electrode for Polluted Wastewater Media
Combined Redox electrode for heavily polluted media in wastewater and process chemistry.
Learn MoreSenseca
UNICON-PH-01/02 pH and ORP Converter
pH and ORP converter for process monitoring with programmable ranges of −1.00 to +15.00 pH or ±1500 mV, Pt100/Pt1000 temperature compensation, 4–20 mA output…
Learn More