WETEC

ECD

OZ80 Ozone Analyzer

WaterWater Quality Measurement

Reagentless, panel-mounted ozone analyzer for dissolved ozone monitoring in water.

  • Ozone measurement ranges of 0–2.00 ppm or 0–20.00 ppm

  • Integrated pH sensor and automatic flow control

  • T80 transmitter with 4–20 mA outputs, Modbus RTU communication and three alarm relays

  • 24 VDC or 100–240 VAC power supply

  • Optional automatic ozone sensor cleaning

Quantity
1

Overview

The ECD OZ80 is a reagentless, panel-mounted analyzer designed to measure dissolved ozone in drinking water, industrial cooling water, rinse water and other freshwater samples. It uses an amperometric ozone sensor with a PTFE membrane and is available in measurement ranges of 0.00–2.00 ppm or 0.00–20.00 ppm. The system incorporates an S80 pH sensor, a constant head flow controller and a T80 transmitter, maintaining a consistent sample flow without requiring pressure regulators or rotameters.

The T80 transmitter supports configurable 4–20 mA outputs, RS485 Modbus RTU communication and three alarm relays, with 24 VDC or 100–240 VAC power supply options. The analyzer is factory-calibrated and supplied with pre-wired sensors and assembled flow tubing to simplify installation. An optional automatic spray cleaning system helps reduce contaminant accumulation on the ozone sensor.

Typical Applications

  • Residual ozone monitoring in drinking water

  • Ozone concentration measurement in industrial cooling water

  • Ozone monitoring in industrial rinse water

  • Residual ozone monitoring in wastewater

  • Ozone measurement in other freshwater disinfection and oxidation processes

Key Features

  • Reagentless amperometric ozone measurement with PTFE membrane

  • Ozone measurement ranges of 0.00–2.00 ppm or 0.00–20.00 ppm

  • Integrated S80 pH sensor with replaceable electrode cartridge

  • Automatic sample flow control from 38 to 300 L/h

  • Panel-mounted system with pre-wired sensors and assembled flow tubing

  • T80 transmitter with configurable 4–20 mA outputs

  • RS485 Modbus RTU communication and three configurable alarm relays

  • 128 × 64 pixel LCD with LED backlight and graphical display options

  • IP65 weatherproof transmitter housing

  • 24 VDC or 100–240 VAC power supply options

  • Factory-calibrated analyzer and sensors

  • Optional automatic spray cleaning system for the ozone sensor

Benefits

  • Reduced operating costs through reagentless ozone and pH measurement

  • Simultaneous ozone and pH monitoring from a single analyzer

  • Consistent sample flow without external pressure regulators or rotameters

  • Simplified installation with a pre-wired, panel-mounted assembly

  • Reduced risk of clogging and blockages with large flow tubes and cells

  • Easy integration into process control and monitoring systems

  • Reduced maintenance requirements through extended sensor electrolyte life

  • Reduced contaminant accumulation with optional automatic ozone sensor cleaning

Specifications

Ozone Measurement

Measuring principle

Amperometric

Sensor communication

Digital protocol

Cathode material

Gold

Anode material

Silver/silver bromide

Membrane material

PTFE

Measurement range – Low

0.00–2.00 ppm

Measurement range – High

0.00–20.00 ppm

Accuracy

±2% of range, dependent on calibration

Resolution

1.0 ppb

Response time

T90 in 2 minutes

Electrolyte life

Up to 12 months

 

 

pH Measurement

Sensor model

S80 pH

Sensor communication

Digital S80 protocol

Sensor body material

316L stainless steel

Electrode design

Replaceable electrode cartridge

Sensor measurement range

1–11 pH

Analyzer measurement range

0.00–14.00 pH

Resolution

0.01 pH

Accuracy

0.05 pH

Temperature measurement accuracy

±0.2 °C

 

 

Sample Flow and Operating Conditions

Flow control

Constant Head Flow Controller (CHFC)

Sample flow range

38–300 L/h (10–80 gal/h)

Sample pressure

1–30 psig (0.1–2 bar)

Operating sample temperature

0–50 °C (32–122 °F)

Wetted materials

PVC, PP, PVDF, PTFE, glass and 316 stainless steel

Sample inlet

¼″ FNPT with ¼″ barbed fitting

Sample drain

¾″ FNPT

 

 

Transmitter and Display

Transmitter model

T80

Display type

LCD with LED backlight

Display resolution

128 × 64 pixels

Display dimensions

2.75″ × 1.5″

Display colour (backlight off)

Black on grey background

Display colour (backlight on)

Blue on white background

Display language

English

Graphical display modes

Bar, gauge and line

 

 

Outputs and Communication

Analogue output type

Configurable 4–20 mA, sourcing

Number of analogue outputs

One or two (two standard)

Maximum loop resistance

600 Ω

First analogue output

Ozone, configured to the sensor measurement range

Second analogue output (optional)

pH (0–14 pH) or temperature

Digital communication interface

RS485

Communication protocol

Modbus RTU (standard)

 

 

Alarm Relays

Number of relays

3

Relay type

SPDT, Form C

Maximum voltage rating

250 VAC

Maximum current rating

10 A (resistive load)

Contact configuration

Normally open (NO) or normally closed (NC)

Configurable relay functions

High/low alarms with expiration timer, periodic timers or fault alarms

 

 

Power Supply

DC power supply

24 VDC (18–36 VDC)

DC power requirement

250 mW minimum

AC power supply

100–240 VAC

AC supply frequency

50/60 Hz

AC power consumption

4 W

AC fuse protection

250 V, 1 A, slow-blow fuse

 

 

Mechanical

System configuration

Panel-mounted

Mounting panel material

PVC

Installation type

Wall mounting

Transmitter enclosure material

Polycarbonate

Transmitter enclosure colour

Beige

Transmitter enclosure format

½ DIN

Transmitter enclosure dimensions (L × W × D)

14.4 × 14.4 × 9.0 cm (5.7 × 5.7 × 3.5″)

Transmitter enclosure protection

IP65

Panel mounting holes

4 × Ø 0.265″

Mounting hardware

¼″-20 or 6 mm metric hardware

 

 

Environmental Conditions

Ambient temperature – 24 VDC models

−20 to +70 °C

Ambient temperature – 100–240 VAC models

−20 to +60 °C

Storage temperature

−30 to +85 °C

Relative humidity

0–80% up to 31 °C, decreasing linearly to 50% RH at 40 °C

Maximum operating altitude

2,000 m (6,500 ft)

Mains supply voltage fluctuation

Up to ±10% of nominal voltage

Transient overvoltage category

CAT II

Pollution degree

2

Outdoor installation

Protective cover or sunshield required

 

 

Calibration and Cleaning

Factory calibration

Analyzer and sensors factory-calibrated

Measurement calibration modes

Automatic, standardization and manual

Ozone calibration reference

DPD-tested ozonized water

Automatic cleaning

Optional spray cleaner on the ozone flow cell

Cleaning cycle control

One relay allocated to spray cleaning when the option is installed

 

 

Standards and Certifications

EMC directive

2004/108/EC

EMC standard

EN 61326-1

CE marking

Available on line-powered transmitters

Drawing

OZ80 Ozone Analyzer Drawing

Downloads

OZ80 - Ozone Analyzer Instruction Manual DownloadOZ80 - Ozone Analyzer Instruction Manual