ECD
PA80 Peracetic Acid Analyzer
Reagentless, panel-mounted peracetic acid (PAA) analyzer for water monitoring applications.
PAA measurement ranges: 0–200 ppm or 0–2000 ppm
pH measurement range: 0–14 pH
Automatic constant-head flow control
T80 transmitter with 4–20 mA outputs, Modbus RTU and three alarm relays
Optional automatic spray cleaning system
Overview
The ECD PA80 is a reagentless analyzer designed to monitor peracetic acid (PAA) concentrations in water. It incorporates an amperometric PAA sensor, a pH sensor, a constant-head flow controller and a T80 transmitter mounted on a PVC panel. The analyzer offers PAA measurement ranges of 0–200 ppm or 0–2000 ppm and a pH measurement range of 0–14 pH.
The flow control system maintains consistent sample flow past the sensors. The T80 transmitter supports 4–20 mA outputs, Modbus RTU communication, three configurable alarm relays and graphical measurement displays. The analyzer operates on 24 VDC or 100–240 VAC, depending on the configuration. An optional automatic spray cleaning system helps reduce contaminant accumulation on the PAA sensor.
Typical Applications
Peracetic acid monitoring in drinking water
Disinfectant monitoring in industrial cooling water and cooling towers
Municipal wastewater treatment monitoring
Rinse water and bottle washing monitoring in food and beverage processing
Sanitization monitoring in pharmaceutical and medical industries
Key Features
Reagentless amperometric peracetic acid (PAA) sensor
PAA measurement ranges of 0–200 ppm or 0–2000 ppm
Integrated pH measurement range of 0–14 pH
Automatic constant-head flow control
Sample flow range of 38–300 L/h
Sensor operating temperature range of 0–50 °C
T80 transmitter with line, bar and gauge display options
One or two 4–20 mA outputs with Modbus RTU communication
Three configurable alarm relays
24 VDC or 100–240 VAC power supply options
IP65 transmitter enclosure
Pre-wired, PVC panel-mounted assembly
Optional automatic spray cleaning system
Benefits
Reduced operating costs through reagentless measurement
Simplified installation with a pre-wired, panel-mounted assembly
Consistent sample flow without additional pressure regulators or rotameters
Additional process information through integrated pH measurement
Reduced risk of clogging and blockages with large flow tubes and cells
Flexible integration with process monitoring and control systems
Reduced manual cleaning requirements with the optional automatic spray cleaning system
Specifications
Peracetic Acid Measurement | |
|---|---|
Measuring principle | Polarographic (amperometric) |
Electrode materials | Gold/Silver |
Membrane type | Microporous membrane |
Sensor communication | Digital protocol |
Measurement range – Low (standard) | 0–200 ppm |
Measurement range – High | 0–2000 ppm |
Ranging | Automatic |
Response time | T90 in 2 minutes |
Electrolyte life | Up to 12 months |
Electrolyte refill interval | 3–6 months, depending on operating conditions |
pH compensation | None; measurement degrades above pH 8 |
Chlorine dioxide (ClO₂) interference | 1:1 factor |
Ozone (O₃) interference | Approximately 2500:1 factor |
pH Measurement | |
|---|---|
Measurement range | 0.00–14.00 pH |
Sensor communication | Digital S80 protocol |
Sensor body material | 316L stainless steel |
Electrode cartridge | Replaceable |
Flow Control and Sample Requirements | |
|---|---|
Flow control | Automatic constant-head flow control |
Sample flow range | 38–300 L/h (10–80 gal/h) |
Minimum flow velocity past PAA sensor membrane | 0.5 ft/s |
Sample pressure | 1–30 psig (0.1–2 bar) |
Sample operating temperature | 0–50 °C (32–122 °F) |
Sample inlet connection | ¼″ FNPT with barb fitting |
Sample drain connection | ¾″ FNPT |
Drain condition | Atmospheric pressure |
Wetted materials | PVC, PP, PVDF, PTFE, glass and 316 stainless steel |
Transmitter and Display | |
|---|---|
Transmitter model | T80 |
Display type | LCD |
Display resolution | 128 × 64 pixels |
Display dimensions | 2.75″ × 1.5″ |
Display colour | Black on grey background; blue on white background when LED backlight is on |
Graphical display options | Line, bar or gauge |
Outputs and Communication | |
|---|---|
Analogue output – PAA | One 4–20 mA output, set to the sensor range |
Analogue output – pH | One 4–20 mA output, set to 0–14 pH (optional) |
Standard output configuration | Two 4–20 mA outputs |
Digital communication | Modbus RTU (standard) |
Alarm Relays | |
|---|---|
Number of relays | Three |
Relay type | SPDT, Form C |
Relay configuration | High/low alarms with expiration timer, periodic timers or fault alarms |
Power Supply | |
|---|---|
DC power supply | 24 VDC (18–36 VDC) |
DC power requirement | 250 mW minimum |
AC power supply | 100–240 VAC, 50/60 Hz |
AC power consumption | 4 W |
Fuse protection – AC model | 250 V, 1 A, slow-blow fuse |
Mains supply voltage fluctuation | Up to ±10% of nominal voltage |
Mechanical | |
|---|---|
System mounting | Wall-mounted PVC panel |
Panel mounting holes | Four × Ø 0.265″ |
Mounting hardware compatibility | ¼″-20 or 6 mm metric hardware |
Transmitter enclosure material | Polycarbonate |
Transmitter enclosure colour | Beige |
Transmitter enclosure format | ½ DIN |
Transmitter enclosure dimensions (L × W × D) | 144 × 144 × 90 mm (5.7″ × 5.7″ × 3.5″) |
Transmitter protection rating | IP65, weatherproof |
Environmental Conditions | |
|---|---|
Ambient temperature – DC model | −20 to +70 °C |
Ambient temperature – AC model | −20 to +60 °C |
Storage temperature | −30 to +85 °C |
Relative humidity | 0–80% up to 31 °C, decreasing linearly to 50% at 40 °C |
Maximum operating altitude | 2000 m (6500 ft) |
Transient overvoltage category | CAT II |
Pollution degree | 2 |
Outdoor installation | Protective cover or sunshield required |
Optional Automatic Spray Cleaning System | |
|---|---|
Cleaning system | Solenoid-actuated spray cleaner |
Cleaning location | Peracetic acid flow cell |
Cleaning medium | Process water or air |
Cleaning medium pressure | 20–40 psi (30 psi stated in the introduction) |
Cleaning control | Adjustable timer for cleaning interval and duration |
Relay allocation | One of the three relays used for spray cleaning |
Drawing

Downloads
| PA80 - Instruction Manual | DownloadPA80 - Instruction Manual |
|---|
Related Products

ECD
DCA-23 Seawater Dechlorination Analyzer
The DCA-23 monitors seawater chlorination and dechlorination from 0.00–2.00 ppm chlorine equivalent, featuring reagent-free measurement, flow-independent…
Learn More
ECD
DC80 Dechlorination Analyzer
The DC80 Dechlorination Analyzer uses a zero-shift measurement strategy, automatic flow control and pH compensation to monitor very low total chlorine levels…
Learn More
ECD
CD80 Chlorine Dioxide Analyzer
The CD80 is a reagentless, panel-mounted analyzer for continuous chlorine dioxide (ClO₂) monitoring from 0.05 to 20 ppm, featuring automatic flow control, a…
Learn More
ECD
TC80 Total Chlorine Analyzer
The TC80 is a reagentless, panel-mounted analyzer for total chlorine monitoring in water, featuring amperometric sensing, automatic pH compensation, automatic…
Learn More